Issue 03/01
Buttons on the Basic Operator Panel
Panel/Button
Function
Indicates
Start motor
Stop motor
Change
direction
Jog motor
Functions
Access
parameters
Increase
Decrease
Figure 3-5
Basic Operator Panel Controls
MICROMASTER 411 & COMBIMASTER 411
6SE6400-5CA00-0BP0
The LCD displays the settings currently used by the inverter.
Status
Pressing the button starts the inverter. This button is disabled by
default. To enable this button set P0700 = 1.
OFF1 Pressing the button causes the motor to come to a standstill
at the selected ramp down rate. Disabled by default; to
enable set P0700 = 1.
OFF2 Pressing the button twice (or once long) causes the motor to
coast to a standstill. This function is always enabled.
Press this button to change the direction of rotation of the motor.
Reverse is indicated by a minus (-) sign or a flashing decimal point.
Disabled by default, to enable set P0700 = 1.
Pressing this button while the inverter has no output causes the
motor to start and run at the preset jog frequency. The motor stops
when the button is released. Pressing this button when the motor is
running has no effect.
This button can be used to view additional information.
Pressing and holding the button for 2 seconds from any parameter
during operation, shows the following:
1.
DC link voltage (indicated by d – units V).
2.
Output current. (A)
3.
Output frequency (Hz)
4.
Output voltage (indicated by o – units V).
5.
The value selected in P0005 (If P0005 is set to show any of the
above (1 to 4) then this will not be shown again).
Additional presses will toggle around the above displays.
Jump Function
From any parameter (rXXXX or PXXXX) a short press of the Fn
button will immediately jump to r0000, you can then change another
parameter, if required. Upon returning to r0000, pressing the Fn
button will return you to your starting point.
Quit
In case of a fault or alarm the
message on the operator panel display.
Pressing this button allows access to the parameters.
Pressing this button increases the displayed value.
value
Pressing this button decreases the displayed value.
value
Operating Instructions
3 Commissioning
Effects
button resets the fault or alarm
51