Model CP-2ER Control Panel
Operation, Installation, and Maintenance Manual
Siemens Building Technologies, Inc.
8 Fernwood Road
Florham Park, New Jersey 07932
P/N 315-093523-7
Fire Safety
Siemens Building Technologies, Ltd.
2 Kenview Boulevard
Brampton, Ontario L6T 5E4 CN

Advertisement

loading

Summary of Contents for Siemens CP-2ER

  • Page 1 Fire Safety Model CP-2ER Control Panel Operation, Installation, and Maintenance Manual Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview Boulevard Florham Park, New Jersey 07932 Brampton, Ontario L6T 5E4 CN P/N 315-093523-7...
  • Page 2: Table Of Contents

    Table of Contents INTRODUCTION ....................1 OPERATION ......................2 CONNECTION DIAGRAM ................4-5 INSTALLATION AND WIRING ................7 POWER LIMITED WIRING .................. 8 MAINTENANCE AND TESTING ................9 TROUBLESHOOTING THE SYSTEM ..............9...
  • Page 3: Introduction

    (VISIBLE WITH DOOR CLOSED) 2A AC INPUT CIRCUITBREAKER SERVICE SELECTION JUMPER PLUG P72 (LOCAL) OR P12 (RELEASE) PR-24 POWER PLUG GROUND DISCONNECT PLUG Figure 1 Model CP-2ER INTRODUCTION SIEMENS RESET/LAMP TEST ALARM SILENCE SUPERVISORY SILENCE TROUBLE SILENCE RELEASE DISCONNECT SERVICE SELEC-...
  • Page 4: Operation

    OPERATION For NFPA 72 Local Service: External Output Loading SERVICE SELECTION NOTE: CON- NECTION DIAGRAM Initiating Circuit and Local Protective Signaling Panel Operation SERVICE SELECTION Jumper SERVICE SELECTION VISUAL INDICATORS COLOR Visual Indicators Externally Visible • POWER — Steady on indicates main power is normal. Green —...
  • Page 5 ALARM SILENCE ALARM SILENCE ALARM SILENCE ALARM For NFPA 12A, 13, or 2001 Service: SILENCE SERVICE SELECTION ALARM SILENCE Initiating Circuit and Agent Release Operation ALARM SILENCE ALARM SILENCE SUPERVISORY SILENCE SUPERVISORY SILENCE SUPERVISORY SI- LENCE PERVISORY SILENCE TROUBLE SILENCE TROUBLE SILENCE MANUAL SWITCHES TROUBLE SILENCE...
  • Page 6 ALARM 120mA Class A or Class B. CLASS A CONNECTION 1.78K 1/2W EOL P/N 140-016124 TYPICAL CONNECTION TO FIRE ALARM SYSTEM (When CP-2ER panels are arranged for NFPA Releasing Service) CP-2ER CP-2ER ALARM TROUBLE ALARM TROUBLE BATTERIES 24 VDC Charging Current Normal: 300mA, 24 VDC...
  • Page 7 PE-3/3T DB-3S P/N 315-090875-7 PE-11/11T DB-11 P/N 315-094198-9 DB-3S with DB-ADPT P/N 315-094198-9 AD-11P P/N 315-095659-7 CP-2ER is the compatibility identifier DESIGNATION RATING CIRCUIT Battery General Alarm Audibles e t t Discharge Audibles Discharge Circuit t I * e t t o i t Siemens Building Technologies, Inc.
  • Page 8 OPTIONS 1. Discharge Delay Selection Switch S101 Position II Closed; I Open MANUAL DISCHARGE Dial setting Switch S101 Rotate to change setting NOTE: Dial Discharge Delay Setting Period (seconds) 4. Predischarge/Discharge Delay Operation Selection (TB3, Terminals 10 through 14) Dipswitch PS3 Position I Closed;...
  • Page 9: Installation And Wiring

    Mounting Control Units (Refer to Figure 2) INSTALLATION AND WIRING Power Requirements Figure 2 Mounting Data...
  • Page 10: Power Limited Wiring

    CONNECTION DIAGRAM Installation of Conduit and Outlet Boxes Installation of Detector Bases Wiring (Refer to CONNECTION DIAGRAM) System Operation Test CAUTION: Be sure to prevent release of the agent. Installing Bases CONNECTION DIAGRAM. POWER LIMITED WIRING Wiring Test NOTE: must be observed...
  • Page 11: Maintenance And Testing

    MODULE TERMINATION KNOCKOUT N = NON-POWER LIMITED TERMINALS CP-2ER TB-1 (All positions) 1 or 2 Figure 3 PLM-35 CP-2ER Power Limited Wiring PLM-35 Installation Instructions, MAINTENANCE AND TESTING TROUBLESHOOTING THE SYSTEM OPERATION CONNECTION DIAGRAM CAUTION: Make sure that release circuits and shunt...
  • Page 12 CONNECTION DIAGRAM NOTE: RELEASE DISCONNECT With Class B wiring: Recommended Spare Parts Fuse Rating Part No. With Class A wiring: 105-210734 105-210758 105-215996 P/N 315-093523-7...