9.2.7 Schedule Screen 6 Connection 9.2.8 Lead/Lag Screen 9.3 Service Screen 6.1 Communicate Using a Tablet Through Virtual Control Air M and M+ 9.3.1 Heat/Cool Screen 6.2 To Wire and Mount the Control Air M/M+ 9.3.2 UPM Status Screen 6.3 Additional Information on Connecting Control Air M/M+ to a Controller 9.3.3 Help Screen...
4 | Control Air M/M+ Water to Water Applications Installation & Operation Manual 1 Key to Symbols and Safety Instructions 1.2 Safety Warnings 1.1 Key to Symbols WARNING: ELECTRIC SHOCK HAZARD Warnings Installation and servicing of this equipment can be hazardous due to the electrical components.
Air M is designed for applications where there is one (1) WSHP. The M+ cable driver, and instruction manual are all available for free download Control Air M+ is designed for applications where there is up to fi fty (50) at the Bosch Thermotechnology website.
6 | Control Air M/M+ Water to Water Applications Installation & Operation Manual 3 Specifi cations Description Value Power 24 Vac (+/-15%), 5 VA, 50-60 Hz, Class 2 Backlit LCD display 4.3" resistive touchscreen color LCD discplay with backlighting WQVGA 480x272 px Cable 6 ft.
Installation & Operation Manual Control Air M/M+ Water to Water Applications | 7 4 Physical Dimensions Side View - Right Back View with Mounting Plate 5.440 4.550 5.440 1.242 Mounting Plate 3.938 4.550 4.799 Back View without Mounting Plate Side View - Left...
To this terminal on the Control Air M: a. Hold the Control Air M/M+ as shown in the picture below. 24 VAC (R) b. While fi rmly pressing the 2 tabs on top of the Control Air M/ Black 24 VAC (C) M+, pull on the backplate with your index fi...
On a wall up to 500 feet from the controller Wiring The Control Air M/M+ requires a 24 Vac power supply. It is not powered by Figure 7 the Rnet. Attach the backplate to the wall or panel. If mounting in or on a...
Page 10
1 0 | Control Air M/M+ Water to Water Applications Installation & Operation Manual Establishing Communication Plug the USB-L cable to the USB (Bosch part number 8733-927-403) to USB micro adapter (fi eld supplied) and then to the Android tablet and controller before launching Virtual Control Air M/M+ (Equipment Touch (OEM) app).
The default password for a new Control Air M/M+ is 0000. You can change passwords on the Control Air M/M+ by going to Touchscreen Setup > Passwords screen. You log out on the Setup screen.
Insert the fl ash drive into the USB port at the bottom of the Control Air M/M+. The Control Air M/M+ has a USB port at the bottom that allows you to Cycle power to the Control Air M/M+. update the device's fi rmware from a USB fl ash drive.
Installation & Operation Manual Control Air M/M+ Water to Water Applications | 13 8.4 Compliance External sensor resistance requirements FCC Compliance Temp (°C) Temp (°F) Resistance (Ohms) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
1 4 | Control Air M/M+ Water to Water Applications Installation & Operation Manual 9 The Control Air M and M+ Screens 9.2.1 Unit Settings Screen This screen can be accessed from the Settings menu. This menu allows 9.1 Units Status Screen/Home Page...
Page 15
Installation & Operation Manual Control Air M/M+ Water to Water Applications | 15 BAS Command: The unit factory default for the Occupancy Command Mode Selection Method parameter is set to BAS Command. A qualifi ed technical agent may change This setting is similar to a thermostat mode select feature, which gives the user the the parameter to be BAS Command, if diff...
1 6 | Control Air M/M+ Water to Water Applications Installation & Operation Manual 9.2.2 Device Settings Screen 9.2.2.1.2 Communication This screen lets you edit the information below for the controller. Figure 18 Figure 21 The Device Settings menu allows the user to adjust or reset any settings on the actual Control Air M/M+ module.
Installation & Operation Manual Control Air M/M+ Water to Water Applications | 17 9.2.2.1.3 Router 9.2.2.1.5 Time Master Lets you view or edit the router's ARC156, MS/TP, or Ethernet If the controller can be a BACnet Time Master, this screen lets you network number.
Description About Displays information about the touchscreen fi rmware Figure 26 Lets you defi ne how long the Control Air M can have Inactivity no activity before returning to the Standby screen and Timeout logging out the user. Set to 0 to deactivate this feature...
Installation & Operation Manual Control Air M/M+ Water to Water Applications | 19 9.2.4 Pumps 9.2.6 Setpoints This screen can be accessed from the Home page through the Setting This screen can be accessed from the Settings screen. It allows the user to Menu.
2 0 | Control Air M/M+ Water to Water Applications Installation & Operation Manual 9.2.7 Schedule Screen Week View The Schedule menu can be accessed from the home page through the Settings menu. This screen allows the user to view, add, edit, or delete BACnet schedules in the controller.
Page 21
Installation & Operation Manual Control Air M/M+ Water to Water Applications | 21 Creating Schedule ON Schedule only–Select one (normal for this example) of the following: Normal for a typical occupied period Override for a occupied period that is to override an OFF schedule.
2 2 | Control Air M/M+ Water to Water Applications Installation & Operation Manual 9.3 Service Screen 9.2.8 Lead/Lag Screen This screen is accessed from the Setting screen and allows the user to The Service menu allows the qualifi ed technician to adjust or reset any confi...
Installation & Operation Manual Control Air M/M+ Water to Water Applications | 23 9.3.2 UPM Status Screen The UPM Status screen can be accessed from the home Screen via the Service Menu. Once an alarm is received via pulse feedback from the UPM board, it is displayed in the screen as shown below.
2 4 | Control Air M/M+ Water to Water Applications Installation & Operation Manual 9.3.3 Help Screen Figure 50 The Help screen can be accessed from the home Screen via the Service Menu. From this screen the user is able to access the software version of the controller to which they are connected.
Page 25
Installation & Operation Manual Control Air M/M+ Water to Water Applications | 25 BTC 469503103 A | 02.2019 Data subject to change...
Page 26
2 6 | Control Air M/M+ Water to Water Applications Installation & Operation Manual Data subject to change 02.2019 | BTC 469503103 A...
Page 27
Installation & Operation Manual Control Air M/M+ Water to Water Applications | 27 BTC 469503103 A | 02.2019 Data subject to change...
Page 28
United States Bosch Thermotechnology Corp. 65 Grove Street Watertown, MA 02472 Tel: 866-642-3198 Fax: 603-965-7581 www.boschheatingandcooling.com BTC 469503103 A | 02.2019...