TH-58PZ750U
11.2. Initialization Pulse Adjust
1. Input the White signal to plasma video input.
2. Set the picture controls as follows.
Picture menu : Vivid
Normal : Set
Aspect : Full
3. Connect Oscilloscope to TPSC1 (SC).
Check that the flat section(T1) is less than 40µs.
Check and adjust that the stand down pulse(T2) period are each within specification.
11.3. P.C.B. (Printed Circuit Board) exchange
11.3.1. Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
11.3.2. Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
P.C.B.
P Board
SC Board
SS Board
D, DG Board
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
Test point
T2
TPSC1 (SC)
Name
Test Point
Vsus
TPVSUS (SS)
Vad
TPVAD (SC)
Ve
TPVE (SS)
White balance and Sub brightness for NTSC, PAL, HD, PC and 625i signals
Volume
VR6602 (SC)
160 ± 10µ Sec
Voltage
Vsus ± 2V
VR251 (P)
-90V ± 1V
VR6600 (SC)
Ve ± 1V
VR6000 (SS)
36
Level
Volume
Remarks
*
*