9.9.
Remove the SD-Board
1. Remove the flexible cables (SD1, SD2, SD3 and SD4)
connected to the SD-Board.
2. Remove the flexible cable (SU11-SD11) and the bridge
connectors (SC42-SD42B and SC46-SD46B).
3. Remove the molding prop (×1
4. Remove the screws (×2
Board.
9.10. Remove the SC-Board
1. Remove the SU-Board and SD-Board. (See section 9.8.
and 9.9.)
2. Unlock the cable clampers to free the cable.
3. Disconnect the connectors (SC2 and SC3).
4. Disconnect the flexible cable (SC20).
5. Remove the screws (×8
).
, ×2
) and remove the SD-
) and remove the SC-Board.
9.11. Remove the SS-Board
1. Remove the Tuner unit. (See section 9.5.)
2. Unlock the cable clampers to free the cable.
3. Disconnect the connectors (SS3, SS11 and SS23).
4. Disconnect the flexible cables (SS52 and SS55).
5. Remove the screws (×4
9.12. Remove the Hanger metals and
the Stand brackets
1. Remove the Plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered
by a soft cloth) with the Plasma panel surface facing
downward.
2. Remove the Stand brackets (L, R) fastening screws (×3
each) and the Stand brackets (L, R).
26