TH-42PA20U-P
11.7. Sub brightness setting
INPUT
1 RF
Gray Scale
Pattern
Black 2 %
Black 0 %
HD
Gray Scale
Pattern
Equipment
Setting
Picture:
PANEL W/B
Normal
Aspect:
16:9
Alignment menu
** Adjust at the dark room.
All cut off 1) Set white balance to Cool .
2) Adjust All cut off to start some pixels emission
at black 2% area and no emission at black 0% area.
3) Write down all cut off data.
4) Set white balance to Nornal .
5) Adjust All cut off to set same data of Cool mode.
6) Set white balance to warm .
7) Adjust All cut off to set same data of Cool mode.
8) Change to HD signal.
9) Copy PAL All cut off data to HD mode.
30
Procedure