Panasonic WV-SPN6R481 Operating Instructions Manual
Panasonic WV-SPN6R481 Operating Instructions Manual

Panasonic WV-SPN6R481 Operating Instructions Manual

Extension unit

Advertisement

Quick Links

Operating Instructions
Included Installation Instructions
Extension Unit
WV-SPN6R481
Model No.
Before attempting to connect or install this product,
please read these instructions carefully and save this manual for future use.
The model number is abbreviated in some descriptions in this manual.
PGQX1631XA
Cs0614-2047
Printed in China

Advertisement

loading

Summary of Contents for Panasonic WV-SPN6R481

  • Page 1 Operating Instructions Included Installation Instructions Extension Unit WV-SPN6R481 Model No. Before attempting to connect or install this product, please read these instructions carefully and save this manual for future use. The model number is abbreviated in some descriptions in this manual.
  • Page 2 For Canada For U.S.A. The model number and serial number of this CAN ICES-3(A)/NMB-3(A) product may be found on the surface of the unit. You should note the model number and serial For U.S.A. number of this unit in the space provided and retain this book as a permanent record of your NOTE: This equipment has been tested and purchase to aid identification in the event of...
  • Page 3: Table Of Contents

    Contents Features ............................4 Precautions ........................... 4 Installations ........................... 5 Specifications ..........................14 Standard accessories ........................14...
  • Page 4: Features

    Features This is the RS485 Output unit for the WV-SPN6 series. It will be referred to as RS485 Output unit from here on. Precautions Refer installation work to the dealer. Do not insert any foreign objects. Installation work requires technique and experi- Fire or electrical shock may be caused if water ences.
  • Page 5: Installations

    Installations The following mounting descriptions use model WV-SPN631 as a representative example to explain the mounting process. Read the following descriptions together with the Installation Guide of the respective camera before attempting to mount the camera. Step1 Remove the rear option cover fastening screw on the top of the camera, the rear option cover and the 2 screws located on the upper backside of the camera.
  • Page 6 Step2 Connect the RS485 Output unit to the camera body and temporarily fasten it. Connect the RS485 Output unit's connector (male) to the Rear option connector (female) of the camera body. Note: • Check that the connector is fully inserted. After connecting the RS485 Output unit to the camera body as shown in the illustration below on the right, slide it towards the front.
  • Page 7 Connect the cables to the RS485 Output unit. Step4 Connect a twisted-pair cable (locally procured) to Termination switch RS485 port the RS485 port. When connecting an external device, remove 9 mm - 10 mm {11/32 inches - 13/32 inches} of the outer jacket of the cable and twist the cable core to prevent the short circuit first.
  • Page 8 Information. Click the [Run] button next to [IP Setting Software]. [Panasonic IP Setting] screen will be displayed. After detecting the camera, the MAC Address/ IP address will be appeared. * The displayed camera information is not automatically updated. Click the [Search] button to...
  • Page 9 Select the camera you want to configure, and click [Access Camera]. Note: • When more than one unit is displayed in [Panasonic IP Setting Software] screen, click the unit with the same MAC address as the MAC address printed on the unit that you want to configure.
  • Page 10 By clicking the [Setup] button on the "Live" page, the authentication dialog is displayed. Enter your user name and password, then click [OK]. The default settings are: user name [admin] and password [12345]. The basic setup screen of the camera is displayed, and the [Extension unit] button is displayed in the setup menu column on the left side of the screen.
  • Page 11 Configure the settings of the RS485 and perform an Step6 operational check. Select the [Back unit] tab on the [Extension unit] page of the setup menu. Setup items Setup contents and defaults Automatic detection Control whether or not to auto detect the RS485 Output unit by selecting On/Off.
  • Page 12 <RS485 Parameter List> Setup items Setup contents and defaults RS485 transmission Configure whether or not to control the connection devices through the camera using RS485 communication by selecting On/Off. Default: On Communication method The RS485’s cable communication scheme can be configured to 4-line communications or 2-line communications.
  • Page 13 Install the camera after mounting the cable cover. Step7 Remove the screw (binding head screw: M2.5 x 5 mm {1/4 inches}) from the lower backside of the camera. Note: • Store the removed screw in a safe location for when you choose to remove the RS485 Output unit, as they will not be used from this point onwards.
  • Page 14: Specifications

    Specifications Ambient operating temperature: –10 °C to +50 °C {14 °F to 122 °F} Ambient operating humidity: 10 % to 90 % (no condensation) Serial port: RS485 (For external device control) Camera control protocol: Pelco-D/ Pelco-P/ Custom Dimensions: 71.0 mm (W) x 71.0 mm (H) x 89.2 mm (D) {2-13/16 inches (W) x 2-13/16 inches (H) x 3-1/2 inches (D)} Approx.
  • Page 16 For U.S. and Canada: For Europe and other countries: Panasonic Corporation Panasonic System Communications Company of North America, http://www.panasonic.com Unit of Panasonic Corporation of North America Panasonic Corporation www.panasonic.com/business/ Osaka, Japan For customer support, call 1.800.528.6747 Two Riverfront Plaza, Newark, NJ 07102-5490 Authorised Representative in EU: Panasonic Canada Inc.