Activating and deactivating components and technology objects
5.2 Option handling for ET 200S with reserve modules
5.2.2
Prerequisites for option handling without reserve modules
Requirements
For option handling without RESERVE modules you require:
● Interface module IM151-1 HIGH FEATURE (6ES7151-1BA02-0AB0 and higher)
● Power module PM E-24 ..48 VDC or PM E- 24..48 VDC/24 ..230 VAC
● For configuring the GSD file SI0380E0.GSx as from 10/2006.
Note
You do not require a GSD file for option handling in
● STEP 7 V5.3 SP 3 with HSP0102
You can find the description for option handling in the STEP 7 Online Help or SIMOTION
SCOUT.
5.2.3
Example of use without reserve modules
Configuration variants
Below is an example of the use of option handling without RESERVE modules.
Note: A "0" in the control interface means that this slot number is deactivated in the
configuration and thus does not exist.
70
One of these power modules must be included in the configuration at least once.
STEP 7 as from:
Basic Functions for Modular Machines
Function Manual, 04/2014