hit counter script
Honeywell Enviracaire Elite UV100E Product Data

Honeywell Enviracaire Elite UV100E Product Data

Ultraviolet air treatment system

Advertisement

whole-house air quality system
APPLICATION
When installed in forced air heating and cooling systems, the
UV100E Ultraviolet Air Treatment System kills airborne and
surface micro-organism contaminants.
® U.S. Registered Trademark
Copyright © 2002 Honeywell • All Rights Reserved
UV100E Ultraviolet
Air Treatment System
FEATURES
• UV-C light kills airborne and surface bacteria.
• Continuously emits ultraviolet energy.
• UV lamp does not produce ozone.
• Sealed unit design prevents accidental installer and
homeowner contact with the voltage and with the
ultraviolet rays.
• Safe design prevents lamps from lighting unless the
base is correctly mounted on the HVAC duct.
• Light pipe to safely view the lamp operation.
• Power cord that plugs into 120 Vac electrical outlet.
• Quick and easy lamp replacement.
• Easy lamp maintenance.
• AIRWATCH™ Indicator can be installed to remind
customers when to change lamp.
• To capture and minimize micro-organism pass-through
in residential heating, ventilation and air conditioning
(HVAC) systems, combine the Ultraviolet Air Treatment
System with a high-efficiency air filtration system that
includes an electronic air cleaner.
• Bold Enviracaire Elite look with blue and white styling.
• Five-year limited warranty.
PRODUCT DATA
68-0249-1

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Enviracaire Elite UV100E

  • Page 1 System with a high-efficiency air filtration system that includes an electronic air cleaner. • Bold Enviracaire Elite look with blue and white styling. • Five-year limited warranty. ® U.S. Registered Trademark Copyright © 2002 Honeywell • All Rights Reserved 68-0249-1...
  • Page 2: Specifications

    Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
  • Page 3: Installation

    UV100E ULTRAVIOLET AIR TREATMENT SYSTEM INSTALLATION When Installing this Product… IMPORTANT If mounting options are limited, protect plastic or rub- 1. Read these instructions carefully. Failure to follow them ber material listed in CAUTION with ultraviolet-resis- could damage the product or cause a hazardous tant material such as aluminum foil duct tape.
  • Page 4 UV100E ULTRAVIOLET AIR TREATMENT SYSTEM CONDENSER COOLING AIR CONDITIONED AIR TO ROOM COIL IRRADIATION UNIT LOCATION REMOTE CONDENSER SECTION (HIGH SIDE) RETURN CONDENSATE DRAIN SINGLE-LAMP REFRIGERANT PIPING AND DUAL-LAMP UNIT LOCATION FURNACE HEAT EXCHANGER ELECTRONIC AIR CLEANER HIGH EFFICIENCY M13529A AIR CLEANER Fig.
  • Page 5 UV100E ULTRAVIOLET AIR TREATMENT SYSTEM COIL IRRADIATION 3-1/2 (89) (25) (178) 2-1/4 (57) 4 (102) 14-7/8 (379) 3-1/2 (89) 4-1/2 (114) M17661A 7 (178) SINGLE-LAMP 3-1/2 (89) (25) (178) 2-1/4 (57) 7-7/16 (188) 4 (102) 3-1/2 (89) 4-1/2 (114) M17662A 7 (178) 5 (127) 3-1/2 (89)
  • Page 6 UV100E ULTRAVIOLET AIR TREATMENT SYSTEM 3. Place the appropriate template for your model on the duct surface, centering the lamp hole(s) on the duct. See Fig. 3 (below and next page) for the template for your model. ALIGN EITHER OF THESE LINES AS CLOSE AS POSSIBLE TO DUCT CENTER LINE CENTER OF 2 IN.
  • Page 7 UV100E ULTRAVIOLET AIR TREATMENT SYSTEM 68-0249-1...
  • Page 8: Mercury Notice

    UV100E ULTRAVIOLET AIR TREATMENT SYSTEM 14. Plug the cord into the nearby 120 Vac electrical outlet. CAUTION 15. Reconnect the power to the HVAC system. 16. Choose a location on the adjacent HVAC equipment for Breakable Glass Hazard. the HVAC maintenance label included in the air Can cause personal injury.
  • Page 9: Maintenance

    UV100E ULTRAVIOLET AIR TREATMENT SYSTEM MAINTENANCE UV LAMP CLEANING REMINDER SCHEDULE How You Can Maintain Your Ultraviolet , (year) INSTALLATION DATE: (month) Air Treatment System YEAR Your should regularly clean your ultraviolet lamps to maintain your air treatment system. And once every year, you must remember to replace your ultraviolet lamps.
  • Page 10: Replacing Your Lamps (Annually)

    UV100E ULTRAVIOLET AIR TREATMENT SYSTEM 7. Rotate the lamp clockwise until it snaps into place with CAUTION the lamp light indicator aligned with the raised button on the unit cover. UV Lamp Burn Hazard. Harmful to bare skin. Can cause severe burns. Disconnect power 15 minutes before removing the ultraviolet lamp(s).
  • Page 11: Uv100E Parts List

    UV100E ULTRAVIOLET AIR TREATMENT SYSTEM UV100E Parts List. Unit Description Replacement Lamps Wattage UV100E1001 Single-Lamp UC100E1006 Return Air Unit UV100E1019 Dual-Lamp UC100E1014 (twin pack) 36W each lamp Return Air Unit (two lamps provided) UV100E1035 Coil Irradiation Unit UC100E1030 UC100E1014 UC100E1030 UC100E1006 UV100E1001 SINGLE LAMP UV100E1019 DUAL LAMP...
  • Page 12 UV100E ULTRAVIOLET AIR TREATMENT SYSTEM M18621 Automation and Control Solutions Automation and Control Solutions Honeywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled 68-0249-1 G.H.

This manual is also suitable for:

Uv100a

Table of Contents