Page 1
Owner’s Manual SPLIT-TYPE ROOM AIR CONDITIONER Climate 5000 RAC 2,6-2 IBW / OU- OUE RAC 3,5-2 IBW / OU- OUE RAC 5,3-2 IBW / OU- OUE RAC 7-2 IBW / OU- OUE IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
Safety Precautions Table of Content Safety Precautions Read Safety Precautions Before Installation Safety Precautions ............2 Incorrect installation due to ignoring instructions can cause serious Unit Specifications and Features......... 4 damage or injury. Unit Parts ............... 4 Achieving Optimal Performance ......... 4 The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.
Page 3
Safety Precautions CAUTION • If the air conditioner is used together with burners or other heating source, thoroughly ventilate the room to avoid oxygen deficiency. • Turn off the air conditioner and isolate the unit if you are not going to use it for a long time.
Unit Specifications and Features Unit Specifications and Features Unit Parts Front Panel Power Cable (Some Units) Remote Control Remote Control Holder (Some Units) Louver Display window (A) Display window (B) Display window (C) defrost timer defrost timer “defrost” when DEFROST feature is activated. “run”...
Unit Specifications and Features Inverter Split Type Other Features • Auto-Restart COOL mode HEAT mode DRY mode If the unit loses power, it will automatically restart with the prior settings once power has been restored. Room 17°C - 32°C 0°C - 30°C 10°C - 32°C Temperature •...
Page 6
Unit Specifications and Features SLEEP Operation +/- 1°C +/- 1°C 7 hours temperature 1 hr 1 hr timer off Saving energy during sleep Fig. 4. Fig. 2. CAUTION Do not put your fingers in or near the blower and suction side of the unit. The high-speed fan inside the unit may cause injury.
Manual Operation (Without Remote) Manual Operation (Without Remote) Care and Maintenance How to operate your unit without the remote control Cleaning Your Indoor Unit In the event that your remote control fails to work, your unit can be WARNING operated manually with the MANUAL CONTROL button located on the indoor unit.
Care and Maintenance CAUTION • Any maintenance and cleaning of outdoor unit should be performed by Qualified Personnel or a licensed service provider. • Any unit repairs should be performed by Qualified Personnel or a licensed service provider. Filter Tab Maintenance – Long Periods of Non-Use If you plan not to use your air conditioner for an extended period of time, do the following: Remove air freshening filter from back...
Troubleshooting Troubleshooting CAUTION SAFETY PRECAUTIONS If ANY of the following conditions occur, isolate immediately! • The power cord is damaged or abnormally warm • You smell a burning odour • The unit emits loud or abnormal sounds • A power fuse blows or the circuit breaker frequently trips •...
Page 10
Troubleshooting Troubleshooting When troubles occur, please check the following points before contacting a repair company. Problem Possible Causes Solution Poor Cooling Performance Temperature setting may be higher than ambi- Lower the temperature setting ent room temperature The heat exchanger on the indoor or outdoor Clean the affected heat exchanger unit is dirty The air filter is dirty...
European Disposal Guidelines European Disposal Guidelines This appliance contains refrigerant and other potentially hazardous materials. When disposing of this appliance, the law requires special collection and treatment. Do not dispose of this product as household waste or unsorted municipal waste. When disposing of this appliance, you have the following options: •...
Page 12
Bosch Thermotechnology Ltd Cotswold Way Warndon Worcester WR4 9SW mailto: Commercial.enquiry@uk.bosch.com Contact Number 03301233004 Web address www.bosch-industrial.co.uk...