DT8360CM-SN / DT8360ACM-SN DUAL TEC® Ceiling
Mount Motion Sensor

Installation Instructions

1. Select the Mounting Location
Mounting location guidelines:
The range is obtained at a mounting height of 2.4m (8') to 8m (26'). Max. detection range at 8m (26') is Ø 21m (70').
Allow a clear line-of-sight to all areas to protect.
Avoid mounting anything within 30cm (12") in front of the sensor.
Do not directly face windows.
Avoid close proximity to moving machinery, fluorescent lights, and heating/cooling sources. Avoid use in turbulent air.
Not for use in applications with pets.
2. Open the Sensor
1.
Turn the arrow to point to the Unlock symbol.
2.
Press firmly on housing latch.
3.
Gently separate the front and rear housing.
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell DUAL TEC DT8360ACM-SN

  • Page 1: Installation Instructions

    DT8360CM-SN / DT8360ACM-SN DUAL TEC® Ceiling Mount Motion Sensor Installation Instructions 1. Select the Mounting Location Mounting location guidelines: • The range is obtained at a mounting height of 2.4m (8’) to 8m (26’). Max. detection range at 8m (26’) is Ø 21m (70’). •...
  • Page 2: Mount The Sensor

    3. Mount the Sensor [A] = Fixed mounting holes [B] = Adjustable mounting slots from 61mm-85mm (2.4”-3.3”) [C] = Tamper hole *This accessory is not covered by the approval. 4. Wire the Sensor For new polling loop installations, always use shielded twisted pair wiring.
  • Page 3 6. Walk Test the Sensor and Adjust as Needed Close the sensor and apply power to the sensor. Initialization is Trouble complete when the LED stops flashing slowly (about 30 seconds). Power Walk Test Anti-Mask Normal Walk through the detection area and observe the LED. [15 min.] Fault (DT8360ACM-SN...
  • Page 4: Detection Patterns

    7. Detection Patterns Note: Attention detection beams go across access points such as windows, doors during sensor installation - 4 -...
  • Page 5 8. Coverage Pattern Masking (DT8300-CPM) A set of 60° masks are provided for masking undesired areas. Attach the masks on the outside of the detector. With the supplied masks, you can mask 60°, 120°, 180° or 240°. Refer to the following examples: Note: To mask a certain area, attach the mask on the opposite side of the sensor, referring to the following examples.
  • Page 6: Troubleshooting

    • Microwave supervision failure: The sensor is check the device functionalities work normally. operating in PIR mode only. • Access https://www.honeywell.com/contact- • PIR self-test failure: The sensor is disabled. us/vulnerability-reporting to report any vulnerability. • Temperature compensation failure: The temperature compensation is disabled.
  • Page 7 (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable. To protect the environment, a detailed installation guide is available on the Honeywell website – Please consider before printing the document! ...