Mechanical ambient conditions
SIMOTION D410 meets the following standards for mechanical stress:
• Vibration load: DIN EN 60721-3-3, Class 3M4
• Shock load: DIN EN 60721-3-3, Class 3M4
• Free fall: DIN EN 60721-3-2, Class 2M1 and 2M2
• Toppling: DIN EN 60721-3-2, Class 2M1
The mechanical ambient conditions for SIMOTION D410 are listed in the following table in
the form of sinusoidal vibrations.
Table 6-8
Mechanical ambient conditions
Ambient conditions
Vibration tested in accordance with
DIN EN 60068-2-6
Shock resistance tested in accordance with
DIN EN 60068-2-27
Vibration reduction
If SIMOTION D410 is subjected to larger shocks or vibrations, you must use suitable
measures to reduce the acceleration or the amplitude.
We recommend installation on shock-absorbing material (e.g., rubber-metal vibration
dampers).
Climatic ambient conditions
SIMOTION D410 may not be used under the following climatic ambient conditions:
Table 6-9
Climatic ambient conditions
Ambient conditions
Temperature
Relative humidity
Air pressure
Pollutant concentration
D410
Manual, 03/2007 Edition
Operation
10 to 57 Hz: 0.35 mm
58 to 200 Hz: 50 m/s²
10 g peak value, 6 ms duration
100 shocks in each axis vertical with
respect to each other
Application range
From 0 to 40 °C
From 5 to 95 %
From 1080 to 795 hPa
SO
: <0.5 ppm;
2
Relative humidity <60 %, no condensation
H
S: <0.1 ppm;
2
Relative humidity <60 %, no condensation
6.5 Mechanical and climatic ambient conditions
Transport (in packaging)
5 to 9 Hz: 3.5 mm
9 to 200 Hz: 10 m/s²
10 g peak value, 6 ms duration
100 shocks in each axis vertical with
respect to each other
Remarks
Oil mist, ice formation, moisture condensation,
dripping water, spraying water, splashing water and
water jets are not permitted (EN 60204, Part 1)
Without condensation, corresponds to a relative
humidity (RH) severity level 2 according to
IEC 1131-2
-
Test:
10 ppm; 4 days
1 ppm; 4 days
Technical data