HMCS45C,HMCS45CL------------------------------------------------------
INT,
INTo
IFO, IF1 : Set has priority over reset.
Figure 20 Interrupt Circuit Block Diagram
• RESET FUNCTION
The reset is performed by setting the RESET pin to "1"
("High" level) and the HMCS45C gets into operation by setting
it to "0" ("Low" level). Refer to Figure 21. Moreover, the
HMCS45C has the automatic reset function (ACL; Built-in Reset
Circuit). The Built-in Reset Circuit restricts the rise condition of
the power supply. Refer to Figure 22. When the Built-in Reset
Circuit is used, RESET should be connected to
V
ss.
Internal state of the HMCS45C are specified as follows by the
(Reset Statel
Vee
reset function.
Program Counter (PC) is set to 3F address on 31 page (31-
3F).
IIRI, IIRT, liE and CF are reset to "0".
IFO, IFI and TF are set to "1".
Reset/Set of I/O latch and register (Do to 0
15 ,
RO to R6) are
set to "1".
Note that other blocks (Status, Register, Timer/Counter,
RAM, etc.) are not cleared.
(Reset Statel
tfRST
• tRsn includes the time required from the power ON until the operation gets
into the constant state .
• tRST2 is applied when the operation is in the constant state.
Figure 21
RESET Timing
O.2V
V c c - - - - " I
tOFF specifies the period when the power supply is OFF in the case that a short break
of the power supply occurs and the power supply ON/OFF is repeated.
Figure 22 Power Supply Timing for Built-in Reset Circuit
• HALT FUNCTION
When the HLT pin is set to "0" ("Low" level), the internal
clock stops and all the internal statuses (RAM, the Registers, the
Carry F/F, the Status F/F, the Program Counter, and all the in-
ternal statuses) are held. Because all internal logic operation stop,
power consumption is reduced. There are two input/output
statuses in the Halt State. The user should specify either "En-
able" or "Disable" using a mask option at the time of ordering
ROM.
"Enable"1output ........ The Status before the Halt State
is held.
Pull up MOS ... ON
76
LInput. ......... No relation to "Halt"
Since Pull up MOS is ON, Pull up MOS current
flows with output "0" ("Low" level) in the Halt
State (NMOS;ON). When an input signal changes,
transmission current flows into an input circuit.
Also, current flows into Pull up MOS. These cur-
rents are added to the Stand-by Supply Current
(or Halt Current).
"Disable" 10utput ........ High Impedance
(NMOS, PMOS: OFF)
Pull up MOS ... OFF
Input. ......... Input Circuit: OFF