Technical Data

Battery Charger
Article number
Rated voltage
Frequency
Output voltage
Charging current (max.)
Charging time
– PowerPack 300, approx.
– PowerPack 400, approx.
– PowerPack 500, approx.
Operating temperature
Storage temperature
Weight, approx.
Degree of protection
The values given are valid for a nominal voltage [U] of 230 V. For different voltages and models for specific countries, these values can vary.
Operation

Initial Operation

Connecting the charger to the mains (see figure A)
 Observe the mains voltage! The voltage of the power
supply must correspond with the data given on the name-
plate of the battery charger. Battery chargers marked with
230 V can also be operated with 220 V.
Plug the charger plug 3 of the power cord into the charger
socket 2 of the charger.
Connect the mains cable (country-specific) to the mains
supply.
Charging the removed battery (see figure B)
Switch the battery pack off and remove it from the holder of
the eBike. For this, read and observe the operating instruc-
tions of the battery pack.
 Place down the battery pack only on clean surfaces. In
particular, avoid soiling the charge socket and the con-
tacts, e. g. by means of sand or soil.
Insert the charger plug 5 of the battery charger into the socket
6 on the battery pack.
Charging the battery on the Bike (see figures C and D)
Switch the battery off. Clean the cover of the charge socket 7.
Prevent especially the charge socket and the contacts from
getting dirty, e.g. by sand or soil. Lift the cover of the charge
socket 7 and plug the charge connector 5 into the charge
socket 6.
Bosch eBike Systems
Standard Charger
(36–4/230)
0 275 007 907
V~
207...264
Hz
47...63
V
36
A
4
h
2.5
h
3.5
h
4.5
°C
–5 ...+40
°C
–10 ...+50
kg
0.8
IP 40
 Charge the battery only in accordance with all safety
instructions. If this is not possible, remove the battery
from the holder and charge it in a more suitable location.
When doing so, read and observe the operating instruc-
tions of the battery.
Charging with Two Battery Packs Inserted
If two battery packs are mounted on one eBike, both battery
packs can be charged using the unsealed connection. The
charging process will charge both battery packs alternately,
automatically switching between both battery packs numer-
ous times. The charging times add up.
Both battery packs are also discharged alternately during
operation.
If you take the battery packs out of the holders, you can
charge each battery pack individually.
Charging Procedure
The charging procedure begins as soon as the charger is
connected to the battery or the charge socket on the bike and
the main power supply.
Note: Charging is only possible if the temperature of the
eBike battery is within the permitted charging temperature
range.
Note: The drive unit is deactivated during the charging
procedure.
The battery can be charged with and without the on-board
computer. When charging without the on-board computer,
the charging procedure can be observed on the battery
charge-control indicator.
When the on-board computer is connected, a corresponding
message is shown on the display.
Standard Charger
Compact Charger
(36–4/100-230)
(36–2/100-240)
0 275 007 923
0 275 007 915
90...264
47...63
36
4
2.5
3.5
4.5
–5 ...+40
–10 ...+50
0.8
IP 40
0 275 007 XCX | (19.4.17)
English–2
90...264
47...63
36
2
5
6.5
7.5
–5 ...+40
–10 ...+50
0.6
IP 40