Siemens HiPath 3000 Series Service Documentation page 1038

Table of Contents

Advertisement

service.fm
Service
Guided Maintenance
Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
Error Class 09 - Hardware Module Messages
09-000 !microprocessor
fault on, common
09-001 !microprocessor
fault off, common
09-002 !loadware memo-
ry fault on, com-
mon
09-003 !loadware memo-
ry fault off, com-
mon
09-029 !line interruption
(error on)
09-030 !short circuit (er-
ror on)
09-031 !under voltage
(error on)
09-032 !thermal over-
load (error on)
09-036 !slip detected on
(STMD)
12-64
Meaning
Microprocessor er-
ror.
The microproces-
sor error has been
corrected.
Error in loadware
memory.
Error in loadware
memory has been
corrected.
Line interruption
Short circuit on the
board specified.
Under voltage.
The specified
board is overheat-
ed.
A bit slip has oc-
curred on an ISDN
line.
Required Measures
Check power at the power
supply unit.
If this error persists, re-
place the central control
board.
None
Replace the board if nec-
essary.
None
Check the line and termi-
nal.
Check the line, terminal,
and port.
Check the power and line
at the terminal's power
supply unit.
Check the fan and air sup-
ply in the 19" housing.
Note the ambient tempera-
ture.
Check the S
line.
0
If necessary, reload the
board or perform a hard re-
start.
If the error persists, set up
an ISDN trace.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
Note
The problem
may be caused
by asynchro-
nous internal
and external
clock rates.
Data loss possi-
ble/connection
may be terminat-
ed.