4.2.1.18 Configure Total System

Meaning
With this call, the desired total configuration is transferred to the CP 142-2 and
saved on the CP 142-2 as the desired configuration.
This configures the CP 142-2.
The following data are transferred:
The list of configured slaves specifying the slaves that can be activated
±
by the CP 142-2 in the protected mode.
The list of configuration data specifying the ID codes and I/O configurations the slaves must
±
have.
The list of parameters saved in non-volatile memory on the CP. This is transferred to the slaves
±
during the startup of the CP 142-2.
The flags that determine the operating mode of the CP 142-2.
±
The call is not executed in the protected mode.


Structure of the job data in the send buffer
Bit 7
Byte 0
1 H
Byte 1
Byte 2
LPS slave 0 to 3
Byte 3
LPS slave 8 to 11
Byte 4
LPS slave 16 to 19
Byte 5
LPS slave 24 to 27
Byte 6
ID code slave 0
Byte 7
ID code slave 1
Byte 8
ID code slave 2
Byte 9
ID code slave 3
Byte 10
ID code slave 4
Byte 11
ID code slave 5
Byte 12
ID code slave 6
Byte 13
ID code slave 7
Byte 14
ID code slave 8
Byte 15
ID code slave 9
Byte 16
ID code slave 10
Byte 17
ID code slave 11
Byte 18
ID code slave 12
Byte 19
ID code slave 13
Byte 20
ID code slave 14
Byte 21
ID code slave 15
Byte 22
ID code slave 16
Byte 23
ID code slave 17
Byte 24
ID code slave 18
Bit 4
Bit 3
Bit 0
A H
LPS slave 4 to 7
LPS slave 12 to 15
LPS slave 20 to 23
LPS slave 28 to 31
I/O conf. slave 0
I/O conf. slave 1
I/O conf. slave 2
I/O conf. slave 3
I/O conf. slave 4
I/O conf. slave 5
I/O conf. slave 6
I/O conf. slave 7
I/O conf. slave 8
I/O conf. slave 9
I/O conf. slave 10
I/O conf. slave 11
I/O conf. slave 12
I/O conf. slave 13
I/O conf. slave 14
I/O conf. slave 15
I/O conf. slave 16
I/O conf. slave 17
I/O conf. slave 18