Technical data
9.2 Electrical specifications
Variable
Combined error F
Min. initial loading E
Maximum working load L
Break load L
Supply voltage U
Maximum supply voltage 18 V DC
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
Output resistance R
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
Sensor material
Degree of protection according to EN 60 529
Cable connection cable length
1) Type approval according to OIML available soon
2) Output is current-calibrated
9.2
Electrical specifications
Permissible ambient temperature range
-20 °C ≤ Ta ≤ +40 °C
Zone 0 and 20 in type of protection "ia/ib" intrinsic safety
Only connect the transmitter, in accordance with the certificate of compliance, to devices
certified as intrinsically safe. deleted
Be sure to observe the respective values.
For SIWAREX WL230, WL250, WL260, WL270 CP-S SA, WL270 CP-S SB
Maximum values of the auxiliary power supply and signal circuit
U
= 20 V DC
i
L
= 40 μH
i
64
comb
min
u
d
SR
Rated
o
i
o
is
tn
tu
ts
I
= 600 mA
i
C
= 12 nF
i
Value
≤± 0.0230 % Cn for C3
≤± 0.0175 % Cn for C4
0 kg
150% E
max
300% E
max
5 ... 12 V DC
3.0 ± 0.008 mV/V
2)
≤ ± 1.0% C
n
700 ± 7 Ω
703 ± 4 Ω
5000 MΩ at 50 V DC
-10 to +40 °C
-35 to +65 °C
-40 to +80 °C
Steel, nickel-plated
IP67
Four-core, shielded
9 m
P
= 6 W
i
Operating Instructions, 07/2016, A5E02199611B-03
SIWAREX WL200