hit counter script
IBM Power Series Handbook

IBM Power Series Handbook

Finding parts, locations, and addresses
Hide thumbs Also See for Power Series:
Table of Contents

Advertisement

Power Systems
Finding parts, locations, and addresses
IBM

Advertisement

Table of Contents
loading

Summary of Contents for IBM Power Series

  • Page 1 Power Systems Finding parts, locations, and addresses...
  • Page 3 Power Systems Finding parts, locations, and addresses...
  • Page 4 Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 313, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. This edition applies to IBM Power Systems servers that contain the POWER7 processor and to all associated models.
  • Page 5: Table Of Contents

    . 181 5802 and 5877 addresses. . 181 5803 and 5873 addresses. . 182 5886 addresses . . 184 5887 addresses . . 184 5888 or EDR1 PCIe storage enclosure addresses . . 185 © Copyright IBM Corp. 2010, 2018...
  • Page 6 System parts . 186 8202-E4B or 8205-E6B system parts . . 186 8202-E4C, 8202-E4D, 8205-E6C, or 8205-E6D system parts . 194 Disk drive and solid-state drive system parts . . 200 Keyboard parts . . 203 8231-E2B system parts . .
  • Page 7: Safety Notices

    You should also refer to the safety information documentation any time you do not clearly understand any safety information in the U.S. English publications. Replacement or additional copies of safety information documentation can be obtained by calling the IBM Hotline at 1-800-300-8751.
  • Page 8 Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v Connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 9 Observe the following precautions when working on or around your IT rack system: v Heavy equipment–personal injury or equipment damage might result if mishandled. v Always lower the leveling pads on the rack cabinet. v Always install stabilizer brackets on the rack cabinet. v To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet.
  • Page 10 CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during relocation. Follow these general guidelines whenever you relocate a populated rack cabinet within a room or building: v Reduce the weight of the rack cabinet by removing equipment starting at the top of the rack cabinet.
  • Page 11 (L003) All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class 1 laser products. Outside the U.S., they are certified to be in compliance with IEC 60825 as a class 1 laser product.
  • Page 12 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call. (C003)
  • Page 13: Finding Parts, Locations, And Addresses

    The string of characters following the enclosure serial number identifies the FRU location within the enclosure: U7879.001.10ABCDE-P3-C31 In this example, P3-C31 is the location of the FRU to be replaced. Use the graphics and tables to locate the FRU and link to its removal and replacement procedure. © Copyright IBM Corp. 2010, 2018...
  • Page 14: What's New In Parts, Locations, And Addresses

    What's new in parts, locations, and addresses Read about new or significantly changed information in parts, locations, and addresses since the previous update of this topic collection. September 2013 The following updates are made to the content: v Added information for 8412-EAD locations. v Added information for 8412-EAD addresses.
  • Page 15: Part Locations And Location Codes

    Added information for 9117-MMB and 9179-MHB system parts. February 2010 ™ ® Added information for IBM Power Systems servers that contain the POWER7 processor. Part locations and location codes You can find part locations by using location codes. Illustrations are provided to help you map a location code to a position on the server or expansion unit.
  • Page 16 Location code topics Description “Location code format” on page 5 Provides descriptive information of the Un value in the location code string. For example, U789C.001. “Location code labels” on page 6 Provides a table that identifies and defines the location code labels.
  • Page 17 Another example follows: Un-P1-C9 is a memory DIMM (C9) that is plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in ®...
  • Page 18: 8202-E4B Or 8205-E6B Locations

    Location code labels The location code label represents a physical part of the server. The following table describes the prefixes of location code labels. Note: These labels apply to system units only. Table 2. Prefixes of location code labels for system units Prefix Description Example...
  • Page 19 Figure 1. Rack front view Figure 2. Rack top view Finding parts, locations, and addresses...
  • Page 20 Figure 3. Rack rear view Stand-alone views Figure 4. Stand-alone front view Finding parts, locations, and addresses...
  • Page 21 Figure 5. Stand-alone side view Figure 6. Stand-alone rear view Memory card locations Finding parts, locations, and addresses...
  • Page 22 Figure 7. Memory card locations PCIe SAS RAID and SSD adapter locations Figure 8. PCIe SAS RAID and SSD adapter locations The following table provides location codes for parts that comprise the server. Table 3. FRU location Failing item removal and replacement Failing item name Physical location code...
  • Page 23 Table 3. FRU location (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Fans Fan 1 Un-A1 See Fans. Fan 2 Un-A2 Fan 3 Un-A3 Fan 4 Un-A4 Power supplies Power supply 1 Un-E1 See Power supply.
  • Page 24 Table 3. FRU location (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Host Ethernet Adapter slot Un-P1-C3 See Host Ethernet adapter. Host Ethernet Adapter 4-Port 1 Gb card Un-P1-C3-T1 - Port 1 Host Ethernet Adapter 4-Port 1 Gb card Un-P1-C3-T2 - Port 2 Host Ethernet Adapter 4-Port 1 Gb card...
  • Page 25 Table 3. FRU location (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Memory card 1 Un-P1-C18 See Memory modules. Memory card 1 - DIMM 1 Un-P1-C18-C1 Memory card 1 - DIMM 2 Un-P1-C18-C2 Memory card 1 - DIMM 3 Un-P1-C18-C3 Memory card 1 - DIMM 4...
  • Page 26 Table 3. FRU location (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Memory card 3 - 20A memory VRM Un-P1-C16-C5 See Memory voltage regulator Memory card 3 - 80A memory VRM Un-P1-C16-C6 module for the 8202-E4B or 8205-E6B.
  • Page 27: 8202-E4C, 8202-E4D, 8205-E6C, Or 8205-E6D

    Table 3. FRU location (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Control panel Control panel Un -D1 See Control panel and signal cables for the 8202-E4B or 8205-E6B systems. Temperature sensor Un -D1 Control panel - USB port Un -D1-T1 Server firmware...
  • Page 28 Location code overview Servers (system unit and expansion units) use physical location codes to provide mapping of replaceable units. Location codes are produced by the server's firmware, which positions them so that they can be used to identify specific parts in a system. The location code format is the same for all servers. If you are working with a specific location code, the unit type and model immediately follow the first character (Utttt.mmm).
  • Page 29 Another example follows: Un-P1-C9 is a memory DIMM (C9) that is plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 30: 8202-E4C, 8202-E4D, 8205-E6C, Or 8205-E6D Locations

    Table 5. Prefixes of location code labels for system units (continued) Prefix Description Example Planar System backplane Port, external cable Unit Virtual planar Worldwide unique ID EIA value for an empty rack location Firmware FRU Worldwide unique identifier The location code label for the worldwide unique identifier consists of the prefix W followed by a maximum of 16 uppercase hexadecimal digits with no leading zeros.
  • Page 31 Figure 10. Rack upper view Figure 11. Rack rear view Stand-alone views for the 8202-E4C or 8205-E6D Finding parts, locations, and addresses...
  • Page 32 Figure 12. Stand-alone front view Figure 13. Stand-alone side view Finding parts, locations, and addresses...
  • Page 33 Figure 14. Stand-alone rear view Memory card locations Figure 15. Memory card locations PCIe SAS RAID and SSD adapter locations Finding parts, locations, and addresses...
  • Page 34 Figure 16. PCIe SAS RAID and SSD adapter locations The following table provides location codes for parts that comprise the server. Table 6. FRU location Failing item removal and replacement Failing item name Physical location code Identify LED procedures System unit Fans Fan 1 Un-A1...
  • Page 35 Table 6. FRU location (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures System port 2 Un-P1-T2 SPCN port 1 Un-P1-T3 SPCN port 2 Un-P1-T4 HMC port 1 Un-P1-T5 HMC port 2 Un-P1-T6 USB port 1 Un-P1-T7 USB port 2 Un-P1-T8...
  • Page 36 Table 6. FRU location (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures GX Dual-Port 12X Channel Attach Un-P1-C1 See GX++ 12X adapter slot 1 channel adapters. GX Dual-Port 12X Channel Attach Un-P1-C1-T1 adapter slot 1 IB-2 card - Port 1 GX Dual-Port 12X Channel Attach Un-P1-C1-T2 adapter slot 1 IB-2 card - Port 2...
  • Page 37 Table 6. FRU location (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Memory card 1 - DIMM 2 Un-P1-C18-C2 Note: The DIMM fault and identify Memory card 1 - DIMM 3 Un-P1-C18-C3 LED is not visible Memory card 1 - DIMM 4 Un-P1-C18-C4 when the system...
  • Page 38: 8231-E2B

    Table 6. FRU location (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Tape drive (USB) Un-P1-D2 Disk drive 1 Un-P2-D1 See Disk drives. Disk drive 2 Un-P2-D2 Disk drive 3 Un-P2-D3 Disk drive 4 Un-P2-D4 Disk drive 5 Un-P2-D5...
  • Page 39 Location code topics Description “Location code overview” Contains background information on the use of location codes. “Physical location codes” Provides a definition for physical location code. “Logical location codes” on page 28 Provides a definition of what a logical location code is. “Location code format”...
  • Page 40 Logical location codes If the physical location cannot be mapped to a physical location code, the server's firmware generates a logical location code. A logical location code is a sequence of location labels that identifies the path that the system uses to communicate with a given resource. Note: A resource has as many logical location codes as it has logical connections to the system.
  • Page 41: 8231-E2B Locations

    Table 7. Unit type and locations Unit type (Utttt.mmm) Link to location information U8231.E2B 8231-E2B Locations Location code labels The location code label represents a physical part of the server. The following table describes the prefixes of location code labels. Note: These labels apply to system units only.
  • Page 42 Figure 17. Front view of base model with six small-form factor (SFF) bays Figure 18. Front view of model with three SFF bays (optional) Figure 19. Top view Finding parts, locations, and addresses...
  • Page 43 Figure 20. Rear view Memory card locations Figure 21. Memory card locations PCIe SAS RAID and SSD adapter locations Finding parts, locations, and addresses...
  • Page 44 Figure 22. PCIe SAS RAID and SSD adapter locations The following table provides location codes for parts that comprise the server. Table 9. FRU location table Failing item removal and replacement Failing item name Physical location code Identify LED procedures System unit Fans Fan 1...
  • Page 45 Table 9. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Disk drive backplane Un-P3 See Disk drive backplane. Ports System port 1 Un-P1-T1 System port 2 Un-P1-T2 HMC port 1 Un-P1-T3 HMC port 2 Un-P1-T4...
  • Page 46 Table 9. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures GX++ 4X channel attach adapter slot 1 Un-P1-C1 GX++ 4X channel adapters. GX++ 4X channel attach adapter slot 1 Un-P1-C1-T1 IB-2 card - Port 1 GX++ 4X channel attach adapter slot 1 Un-P1-C1-T2...
  • Page 47: 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, Or 8268-E1D

    Table 9. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Tape drive (SAS) Un-P1-D1 Tape drive (USB) Un-P1-D2 Disk drive 1 Un-P3-D1 See Disk drives. Disk drive 2 Un-P3-D2 Disk drive 3 Un-P3-D3 Disk drive 4 Un-P3-D4...
  • Page 48 Location code topics Description “Location code overview” Contains background information about the use of location codes. “Physical location codes” Provides a definition for physical location code. “Logical location codes” on page 37 Provides a definition of what a logical location code is. “Location code format”...
  • Page 49 Logical location codes If the physical location cannot be mapped to a physical location code, the server's firmware generates a logical location code. A logical location code is a sequence of location labels that identifies the path that the system uses to communicate with a given resource. Note: A resource has as many logical location codes as it has logical connections to the system.
  • Page 50: 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, Or 8268-E1D Locations

    Table 10. Unit type and locations Unit type (Utttt.mmm) Link to location information U8231.E1C or U8231.E2C 8231-E1C or 8231-E2C locations Location code labels The prefixes in location code labels represent a physical part of the server. The following table describes the prefixes in location code labels.
  • Page 51 Figure 23. Front view of the base model with six small-form factor (SFF) bays Figure 24. Front view of the model with three SFF bays (optional) Figure 25. Top view Finding parts, locations, and addresses...
  • Page 52 Figure 26. Rear view Figure 27. Rear view with feature code EJ0G (optional) Memory card locations Figure 28. Memory card locations PCIe SAS RAID and SSD adapter locations Finding parts, locations, and addresses...
  • Page 53 Figure 29. PCIe SAS RAID and SSD adapter locations The following table provides location codes for parts in a server. Table 12. FRU location table Failing item removal and replacement Failing item name Physical location code Identify LED procedures System unit Fans Fan 1 Un-A1...
  • Page 54 Table 12. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Disk drive backplane Un-P3 See Disk drive backplane. Ports System port 1 Un-P1-T1 System port 2 Un-P1-T2 HMC port 1 Un-P1-T3 HMC port 2 Un-P1-T4...
  • Page 55 Table 12. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Cache battery card Un-P1-C13 See SAS RAID enablement and Battery on cache battery card Un-P1-C13-E1 cache battery RAID and cache storage controller Un-P1-C18 pack.
  • Page 56: 8233-E8B And 8236-E8C

    Table 12. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Tape drive (USB) Un-P1-D2 Disk drive 1 Un-P3-D1 See Disk drives. Disk drive 2 Un-P3-D2 Disk drive 3 Un-P3-D3 Disk drive 4 Un-P3-D4 Disk drive 5 Un-P3-D5...
  • Page 57 Location code topics that might be of interest Description “Location code overview” Contains background information on the use of location codes. “Physical location codes” Provides a definition for physical location code. “Logical location codes” on page 46 Provides a definition of what a logical location code is. “Location code format”...
  • Page 58 Another example follows:, Un-P1-C9 is a memory DIMM, with memory DIMM (C9) plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 59: 8233-E8B And 8236-E8C Locations

    Table 13. Unit type and locations Unit type (Utttt) Link to location information U8233.E8B 8233-E8B or 8236-E8C Locations Location code labels The location code label represents a physical part of the server. The following table describes the prefixes of location code labels. Note: These labels apply to system units only.
  • Page 60 Figure 30. Rack front view Figure 31. Rack top view Finding parts, locations, and addresses...
  • Page 61 Figure 32. Rack rear view Processor book Figure 33. Processor book Location codes The following table provides location codes for parts that comprise the server. Table 15. FRU location table Failing item removal and replacement Failing item name Physical location code Identify LED procedures System unit...
  • Page 62 Table 15. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Fan 1 Un-A1 See Fans. Fan 2 Un-A2 Fan 3 Un-A3 Fan 4 Un-A4 Power supplies Power supply 1 Un-E1 See Power supply.
  • Page 63 Table 15. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Quad 1 GB Ethernet port 3 (middle Un-P1-C6-T3 bottom RJ45 connector) Quad 1 GB Ethernet port 4 (bottom RJ45 Un-P1-C6-T4 connector) External SAS port Un-P2-T1...
  • Page 64 Table 15. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures GX adapters controller slot 1 (rear view - Un-P1-C8 See GX adapters. second slot from center) GX Dual-Port 12X Channel Attach Un-P1-C7 adapter controller slot 2 (rear view - first slot from center)
  • Page 65 Table 15. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Memory module 1 on processor 1 Un-P1-C13-C2 See Memory modules. Memory module 2 on processor 1 Un-P1-C13-C3 Memory module 3 on processor 1 Un-P1-C13-C4 Memory module 4 on processor 1 Un-P1-C13-C5...
  • Page 66: 8248-L4T, 8408-E8D, Or 9109-Rmd

    Table 15. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures SFF Disk drive 1 Un-P2-D3 See Disk drives. SFF Disk drive 2 Un-P2-D4 SFF Disk drive 3 Un-P2-D5 SFF Disk drive 4 Un-P2-D6 SFF Disk drive 5 Un-P2-D7...
  • Page 67 Location code topics Description “Worldwide unique identifier” on page 57 Provides a definition for the worldwide unique identifier. This group of digits follows the resource code labels and always begins with the letter W. Location code overview Servers (system units and expansion units) use physical location codes to provide mapping of replaceable units.
  • Page 68 Another example follows: Un-P1-C9 is memory DIMM (C9), which is plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 69: 8248-L4T, 8408-E8D, Or 9109-Rmd Locations

    Table 17. Prefixes of location code labels for system units Prefix Description Example Air-moving device Fan, blower Card connector IOP, IOA, DIMM, processor card Device Diskette, control panel Electrical Battery, power supply, ac charger Logical path SAS target Integrated drive electronics (IDE) address, Fibre Channel LUN Horizontal placement for an empty rack location Planar...
  • Page 70 Rear Finding parts, locations, and addresses...
  • Page 71 Memory card locations Table 18. FRU location table Failing item removal and Fault and replacement Failing item name Physical location code identify LED procedures System unit Fans Fan 1 Un-A1 See Fans. Fan 2 Un-A2 Fan 3 Un-A3 Fan 4 Un-A4 Fan 5 Un-A5...
  • Page 72 Table 18. FRU location table (continued) Failing item removal and Fault and replacement Failing item name Physical location code identify LED procedures Integrated 10 Gb port Un-P2-C8-T2 Integrated 10 Gb or 1 Gb Ethernet port Un-P2-C8-T3 Integrated 10 Gb or 1 Gb Ethernet port Un-P2-C8-T4 USB top port (integrated multifunction Un-P2-C8-T5...
  • Page 73 Table 18. FRU location table (continued) Failing item removal and Fault and replacement Failing item name Physical location code identify LED procedures Fan connector (second from right) Un-P3-T4 Fan connector (rightmost) Un-P3-T5 Vital product data (VPD) card Un-P2-C7 See VPD card. Service processor Service processor USB port Un-P1-C1-T1...
  • Page 74 Table 18. FRU location table (continued) Failing item removal and Fault and replacement Failing item name Physical location code identify LED procedures Memory card 1 Un-P3-C1 See Memory. Memory card 1 - DIMM 1 Un-P3-C1-C1 Memory card 1 - DIMM 2 Un-P3-C1-C2 Memory card 1 - DIMM 3 Un-P3-C1-C3...
  • Page 75 Table 18. FRU location table (continued) Failing item removal and Fault and replacement Failing item name Physical location code identify LED procedures Memory card 5 Un-P3-C6 See Memory. Memory card 5 - DIMM 1 Un-P3-C6-C1 Memory card 5 - DIMM 2 Un-P3-C6-C2 Memory card 5 - DIMM 3 Un-P3-C6-C3...
  • Page 76: 9117-Mmb And 9179-Mhb

    Table 18. FRU location table (continued) Failing item removal and Fault and replacement Failing item name Physical location code identify LED procedures Disk drive 1 Un-P2-C9-D1 Identify only See Disk drives or solid-state Disk drive 2 Un-P2-C9-D2 drives. Disk drive 3 Un-P2-C9-D3 Disk drive 4 Un-P2-C9-D4...
  • Page 77 Location code overview Servers (system unit and expansion units) use physical location codes to provide mapping of replaceable units. Location codes are produced by the server's firmware, which structures them so that they can be used to identify specific parts in a system. The location code format is the same for all servers. If you are working with a specific location code, the feature immediately follows the first character (U5886).
  • Page 78 Another example follows:, Un-P1-C9 is a memory DIMM, with memory DIMM (C9) plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 79: 9117-Mmb And 9179-Mhb Locations

    Table 20. Prefixes of location code labels for system units (continued) Prefix Description Example Planar System backplane Port Unit Virtual planar Worldwide unique ID EIA value for an empty rack location Firmware FRU Worldwide unique identifier The location code label for the worldwide unique identifier consists of the prefix W followed by a maximum of 16 uppercase hexadecimal digits with no leading zeros.
  • Page 80 Rear Finding parts, locations, and addresses...
  • Page 81 Midplane I/O card Finding parts, locations, and addresses...
  • Page 82 System processor assembly Table 21. FRU location table Failing item removal and replacement Failing item name Physical location code Identify LED procedures System unit Fans Fan 1 Un-A1 See Fans. Fan 2 Un-A2 Fan 3 Un-A3 Fan 4 Un-A4 Fan 5 Un-A5 Power supplies Power supply 1...
  • Page 83 Table 21. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Integrated 10 Gb or 1 Gb ethernet port Un-P2-C8-T3 Integrated 10 Gb or 1 Gb ethernet port Un-P2-C8-T4 USB top port (HEA Card) Un -P2-C8-T5 USB bottom port (HEA Card) Un -P2-C8-T6...
  • Page 84 Table 21. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Service processor FSP cable A connector Un-P1-C1-T1 FSP cable Drawer 4 connector Un-P1-C1-T1 FSP cable Drawer 3 connector Un-P1-C1-T2 FSP cable Drawer 1, 2 connector Un-P1-C1-T3 FSP cable Drawer 5 connector Un-P1-C1-T4...
  • Page 85: 8412-Ead, 9117-Mmc, 9117-Mmd, 9179-Mhc, Or 9179-Mhd

    Table 21. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Memory module 10 Un-P3-C11 Memory module 11 Un-P3-C12 Memory module 12 Un-P3-C13 Memory module 13 Un-P3-C17 Memory module 14 Un-P3-C18 Memory module 15 Un-P3-C19 Memory module 16...
  • Page 86 Location code topics that might be of interest Description “Location code labels” on page 75 Provides a table that identifies and defines the location code labels. The location code labels begin with an alphabetic character and follow the system serial number. For example, U7879.001.10ABCDE-P3-C31-T2-L23.
  • Page 87 Another example follows: Un-P1-C9 is memory DIMM (C9), which is plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 88: 8412-Ead, 9117-Mmc, 9117-Mmd, 9179-Mhc, Or 9179-Mhd Locations

    Note: These labels apply to system units only. Table 23. Prefixes of location code labels for system units Prefix Description Example Air-moving device Fan, blower Card connector IOP, IOA, DIMM, processor card Device Diskette, control panel Electrical Battery, power supply, ac charger Logical path SAS target Integrated drive electronics (IDE) address, Fibre Channel LUN...
  • Page 89 Rear Top (9117-MMC or 9179-MHC with two-processor system unit) Finding parts, locations, and addresses...
  • Page 90 Top (8412-EAD, 9117-MMD, 9179-MHC with four-processor system unit, or 9179-MHD) Table 24. FRU location table Failing item removal and replacement Failing item name Physical location code Identify LED procedures System unit Fans Fan 1 Un-A1 See Fans. Fan 2 Un-A2 Fan 3 Un-A3 Fan 4...
  • Page 91 Table 24. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Small form factor SAS disk drive Un-P2-C9 backplane with embedded SAS adapters Ports Integrated 10 Gb or 1 Gb Ethernet port Un-P2-C8-T1 Integrated 10 Gb or 1 Gb Ethernet port Un-P2-C8-T2...
  • Page 92 Table 24. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Processor Voltage Regulator Module 1 Un-P3-C22 (Proc2 VRM) Processor Voltage Regulator Module 2 Un-P3-C25 (Proc2 VRM) Processor Voltage Regulator Module 3 Un-P3-C26 (Proc2 VRM) Processor Voltage Regulator Module 4...
  • Page 93 Table 24. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures HMC 2 connector Un-P1-C1-T7 SPCN 0 connector Un-P1-C1-T8 SPCN 1 connector Un-P1-C1-T9 Ambient temperature sensor Un-D1 Adapters PCIe adapter in slot 1 Un-P2-C1 PCIe adapter in slot 2 Un-P2-C2...
  • Page 94: 9119-Fhb

    Table 24. FRU location table (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Memory module 3 Un-P3-C3 Memory module 4 Un-P3-C4 Memory module 5 Un-P3-C7 Memory module 6 Un-P3-C8 Memory module 7 Un-P3-C9 Memory module 8 Un-P3-C10 Memory module 9...
  • Page 95 Location code topics Description “Location code overview” Contains background information on the use of location codes. “Physical location codes” Provides a definition for physical location code. “Logical location codes” Provides a definition for a logical location code. “Location code format” on page 84 Provides descriptive information of the Un value in the location code string.
  • Page 96 Another example follows: Un-P1-C9 is a memory DIMM (C9) that is plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 97: 9119-Fhb Locations

    Location code labels The location code label represents a physical part of the server. The following table describes the prefixes of location code labels. Note: These labels apply to system units only. Table 26. Prefixes of location code labels for system units Prefix Description Example...
  • Page 98 Figure 34. Front and rear views Figure 35. Emergency power off (EPO) Finding parts, locations, and addresses...
  • Page 99 Figure 36. Light strip views Figure 37. Bulk power assembly (BPA). Front is Un-P1 and back is Un-P2. Figure 38. Light strip views Finding parts, locations, and addresses...
  • Page 100 Figure 39. Node locations Finding parts, locations, and addresses...
  • Page 101 Figure 40. GX++ card locations (upper nodes) Figure 41. GX++ card locations (lower nodes) The following table provides location codes for parts that make up the server. Note: To remove and replace a failing item, see 9119-FHB removal and replacement procedures. Finding parts, locations, and addresses...
  • Page 102 Table 27. Bulk power assembly (BPA) locations and failing components Failing item name Identify LED Physical location code System unit bulk power assembly (BPA) Bulk power distribution (BPD) Bulk power regulator (BPR) A, front of frame Un-P1 Bulk power regulator (BPR) 4A, top Un-P1–E1 Bulk power regulator (BPR) 3A Un-P1–E2...
  • Page 103 Table 27. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Identify LED Physical location code Connector J10, MDA 1 and 3, Y cable powers Un-Px-C1–J10 2 MDAs Connector J11, MDA 2 and 4, Y cable powers Un-Px-C1–J11 2 MDAs Bulk power distribution (BPD) connectors...
  • Page 104 Table 27. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Identify LED Physical location code Processor book 0, plugs into midplane Un-P2 Processor book 1 Un-P6 Processor book 2 Un-P3 Processor book 3 Un-P7 Processor book 4 Un-P4 Processor book 5 Un-P8...
  • Page 105 Table 27. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Identify LED Physical location code DIMM U-M1-A Un-Pm-C6 DIMM U-M1-B Un-Pm-C7 DIMM U-M1-C Un-Pm-C8 DIMM U-M1-D Un-Pm-C9 DIMM U-M0-A Un-Pm-C10 DIMM U-M0-B Un-Pm-C11 DIMM U-M0-C Un-Pm-C12 DIMM U-M0-D Un-Pm-C13 DIMM V-M0-D...
  • Page 106: 9125-F2C

    Table 27. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Identify LED Physical location code Connector J5, SPCN connector Un-P1–Cm-T5 Book connectors Super UPIC power connector J01 Un-Pn-J01 Super UPIC power connector J02 Un-Pn-J02 Motor drive assembly (MDA) 1 Un-A2–E1 MDA 2 Un-A4–E1...
  • Page 107 Using location codes Use the following table to link to a specific topic that you need additional information about when reading your location code. Location code topics Description “Location code overview” Contains background information about the use of location codes. “Physical location codes”...
  • Page 108 Logical location codes If the physical location cannot be mapped to a physical location code, the server's firmware generates a logical location code. A logical location code is a sequence of location labels that identifies the path that the system uses to communicate with a given resource. Note: A resource has as many logical location codes as it has logical connections to the system.
  • Page 109: 9125-F2C Locations

    Table 28. Unit type and locations Unit type (Utttt.mmm) Link to location information U78A9.001 9125-F2C Locations Location code labels The location code label represents a physical part of the server. The following table describes the prefixes of location code labels. Note: These labels apply to system units only.
  • Page 110 Figure 42. Front and rear view of frame Figure 43. Bulk power control and communications hub (BPCH) and Bulk power distribution (BPD) locations Finding parts, locations, and addresses...
  • Page 111 Figure 44. Memory card locations Finding parts, locations, and addresses...
  • Page 112 Figure 45. Bulk power assembly (BPA) connector locations Figure 46. Bulk power fan (BPF) locations Finding parts, locations, and addresses...
  • Page 113 Figure 47. Distributed converter and control assembly (DCCA) and PCIe riser locations Table 30. Bulk power assembly (BPA) locations and failing components Failing item name Physical location code Frame UEPO panel Un-D1 Connector T1 for BPA -A connection (upper BPA) Un-D1-T1 Connector T2 for BPA-B connection (lower BPA) Un-D1-T2...
  • Page 114 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Un-P2-A3 Un-P2-A4 Bulk power control and communications hub (BPCH) BPCH Un-P2-C1 BPCH connectors Connector T1 Un-P2-C1-T1 Connector T2 Un-P2-C1-T2 Connector T3 Un-P2-C1-T3 Connector T4 Un-P2-C1-T4 Connector T5 Un-P2-C1-T5...
  • Page 115 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Connector T36 Un-P2-C1-T36 Connector T37 Un-P2-C1-T37 Connector T38 Un-P2-C1-T38 Connector T39 Un-P2-C1-T39 Connector T40 Un-P2-C1-T40 Connector T41 Un-P2-C1-T41 Connector T42 Un-P2-C1-T42 Bulk power distribution (BPD) Un-P2-C2 BPD connectors Connector T1...
  • Page 116 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code BPR 4 Un-P1-E1 BPR 2 Un-P1-E2 BPR 12 Un-P1-E3 BPR 10 Un-P1-E4 BPR 8 Un-P1-E5 BPR 6 Un-P1-E6 Bulk power fan (BPF) Un-P1-A1 Un-P1-A2 Un-P1-A3 Un-P1-A4...
  • Page 117 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Connector T28 Un-P1-C1-T28 Connector T29 Un-P1-C1-T29 Connector T30 Un-P1-C1-T30 Connector T31 Un-P1-C1-T31 Connector T32 Un-P1-C1-T32 Connector T33 Un-P1-C1-T33 Connector T34 Un-P1-C1-T34 Connector T35 Un-P1-C1-T35 Connector T36 Un-P1-C1-T36...
  • Page 118 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Connector T23 Un-P1-C2-T23 Connector T24 Un-P1-C2-T24 Connector T25 Un-P1-C2-T25 Connector T26 Un-P1-C2-T26 Water cooling Manifold left Un-M1 Manifold right Un-M2 Rear door heat exchanger (RDHX) Un-M3 Water conditioning unit (WCU) WCU 1...
  • Page 119 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Connector Un-C148-T4 HMC1 connector (FSP) Un-C148-T2 HMC2 connector (FSP) Un-C148-T3 Battery Un-C148-E1 System VPD System VPD card Un-P1-C146 Memory DIMM Memory DIMM Un-P1-C18 Memory DIMM Un-P1-C19 Memory DIMM...
  • Page 120 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Memory DIMM Un-P1-C51 Memory DIMM Un-P1-C52 Memory DIMM Un-P1-C53 Memory DIMM Un-P1-C54 Memory DIMM Un-P1-C55 Memory DIMM Un-P1-C56 Memory DIMM Un-P1-C57 Memory DIMM Un-P1-C58 Memory DIMM Un-P1-C59...
  • Page 121 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Memory DIMM Un-P1-C91 Memory DIMM Un-P1-C92 Memory DIMM Un-P1-C93 Memory DIMM Un-P1-C94 Memory DIMM Un-P1-C95 Memory DIMM Un-P1-C96 Memory DIMM Un-P1-C97 Memory DIMM Un-P1-C98 Memory DIMM Un-P1-C99...
  • Page 122 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Memory DIMM Un-P1-C131 Memory DIMM Un-P1-C132 Memory DIMM Un-P1-C133 Memory DIMM Un-P1-C134 Memory DIMM Un-P1-C135 Memory DIMM Un-P1-C136 Memory DIMM Un-P1-C137 Memory DIMM Un-P1-C138 Memory DIMM Un-P1-C139...
  • Page 123 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code HUB 0 L-Link 20 Un-P1-R1-R16 HUB 0 L-Link 21 Un-P1-R1-R17 HUB 0 L-Link 16 Un-P1-R1-R18 HUB 0 L-Link 17 Un-P1-R1-R19 HUB 0 L-Link 12 Un-P1-R1-R20 HUB 0 L-Link 13 Un-P1-R1-R21...
  • Page 124 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code HUB 1 D-Link 1 Un-P1-R2-R15 HUB 1 L-Link 20 Un-P1-R2-R16 HUB 1 L-Link 21 Un-P1-R2-R17 HUB 1 L-Link 16 Un-P1-R2-R18 HUB 1 L-Link 17 Un-P1-R2-R19 HUB 1 L-Link 12 Un-P1-R2-R20...
  • Page 125 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code HUB 2 D-Link 3 Un-P1-R3-R14 HUB 2 D-Link 1 Un-P1-R3-R15 HUB 2 L-Link 20 Un-P1-R3-R16 HUB 2 L-Link 21 Un-P1-R3-R17 HUB 2 L-Link 16 Un-P1-R3-R18 HUB 2 L-Link 17 Un-P1-R3-R19...
  • Page 126 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code HUB 3 D-Link 5 Un-P1-R4-R13 HUB 3 D-Link 3 Un-P1-R4-R14 HUB 3 D-Link 1 Un-P1-R4-R15 HUB 3 L-Link 20 Un-P1-R4-R16 HUB 3 L-Link 21 Un-P1-R4-R17 HUB 3 L-Link 16 Un-P1-R4-R18...
  • Page 127 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code HUB 4 D-Link 7 Un-P1-R5-R12 HUB 4 D-Link 5 Un-P1-R5-R13 HUB 4 D-Link 3 Un-P1-R5-R14 HUB 4 D-Link 1 Un-P1-R5-R15 HUB 4 L-Link 20 Un-P1-R5-R16 HUB 4 L-Link 21 Un-P1-R5-R17...
  • Page 128 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code HUB 5 D-Link 9 Un-P1-R6-R11 HUB 5 D-Link 7 Un-P1-R6-R12 HUB 5 D-Link 5 Un-P1-R6-R13 HUB 5 D-Link 3 Un-P1-R6-R14 HUB 5 D-Link 1 Un-P1-R6-R15 HUB 5 L-Link 20 Un-P1-R6-R16...
  • Page 129 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code HUB 6 D-Link 11 Un-P1-R7-R10 HUB 6 D-Link 9 Un-P1-R7-R11 HUB 6 D-Link 7 Un-P1-R7-R12 HUB 6 D-Link 5 Un-P1-R7-R13 HUB 6 D-Link 3 Un-P1-R7-R14 HUB 6 D-Link 1 Un-P1-R7-R15...
  • Page 130 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code HUB 7 D-Link 13 Un-P1-R8-R9 HUB 7 D-Link 11 Un-P1-R8-R10 HUB 7 D-Link 9 Un-P1-R8-R11 HUB 7 D-Link 7 Un-P1-R8-R12 HUB 7 D-Link 5 Un-P1-R8-R13 HUB 7 D-Link 3 Un-P1-R8-R14...
  • Page 131 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code QCM 1 or P7-0 Un-P1-R16 QCM 2 or P7-2 Un-P1-R17 QCM 2 or P7-1 Un-P1-R18 QCM 2 or P7-3 Un-P1-R19 QCM 2 or P7-0 Un-P1-R20 QCM 3 or P7-2 Un-P1-R21...
  • Page 132 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code PCIe riser8 Un-P1-C8 PCIe8 Un-P1-C8-C1 PCIe riser9 Un-P1-C9 PCIe9 Un-P1-C9-C1 PCIe riser10 Un-P1-C10 PCIe10 Un-P1-C10-C1 PCIe riser11 Un-P1-C11 PCIe11 Un-P1-C11-C1 PCIe riser12 Un-P1-C12 PCIe12 Un-P1-C12-C1 PCIe riser13...
  • Page 133 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Optical HUB 7 Un-P1-T3-T2 Optical HUB 6 Un-P1-T3-T3 Optical HUB 6 Un-P1-T3-T4 Optical HUB 5 Un-P1-T3-T5 Optical HUB 5 Un-P1-T3-T6 Optical HUB 4 Un-P1-T3-T7 Optical HUB 4 Un-P1-T3-T8...
  • Page 134 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Optical HUB 7 Un-P1-T8-T2 Optical HUB 6 Un-P1-T8-T3 Optical HUB 6 Un-P1-T8-T4 Optical HUB 5 Un-P1-T8-T5 Optical HUB 5 Un-P1-T8-T6 Optical HUB 4 Un-P1-T8-T7 Optical HUB 4 Un-P1-T8-T8...
  • Page 135 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Optical HUB 3 Un-P1-T14-T1 Optical HUB 3 Un-P1-T14-T2 Optical HUB 2 Un-P1-T14-T3 Optical HUB 2 Un-P1-T14-T4 Optical HUB 1 Un-P1-T14-T5 Optical HUB 1 Un-P1-T14-T6 Optical HUB 0 Un-P1-T14-T7...
  • Page 136 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code DCA UPIC Connector Un-E2-T2 System backplane Un-P1 Un-P1-A1 Un-P1-A2 Un-P1-A3 Un-P1-A4 Un-P1-A5 Un-P1-A6 Un-P1-A7 Un-P1-A8 Un-P1-A9 Un-P1-A10 Un-P1-A11 Un-P1-A12 Carrier Un-P1-C1 Drive Un-P1-C1-D1 Drive Un-P1-C1-D2 Drive...
  • Page 137 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Drive Un-P1-C6-D1 Drive Un-P1-C6-D2 Drive Un-P1-C6-D3 Drive Un-P1-C6-D4 Carrier Un-P1-C7 Drive Un-P1-C7-D1 Drive Un-P1-C7-D2 Drive Un-P1-C7-D3 Drive Un-P1-C7-D4 Carrier Un-P1-C8 Drive Un-P1-C8-D1 Drive Un-P1-C8-D2 Drive Un-P1-C8-D3...
  • Page 138 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Drive Un-P1-C14-D1 Drive Un-P1-C14-D2 Drive Un-P1-C14-D3 Drive Un-P1-C14-D4 Carrier Un-P1-C15 Drive Un-P1-C15-D1 Drive Un-P1-C15-D2 Drive Un-P1-C15-D3 Drive Un-P1-C15-D4 Carrier Un-P1-C16 Drive Un-P1-C16-D1 Drive Un-P1-C16-D2 Drive Un-P1-C16-D3...
  • Page 139 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Drive Un-P1-C22-D1 Drive Un-P1-C22-D2 Drive Un-P1-C22-D3 Drive Un-P1-C22-D4 Carrier Un-P1-C23 Drive Un-P1-C23-D1 Drive Un-P1-C23-D2 Drive Un-P1-C23-D3 Drive Un-P1-C23-D4 Carrier Un-P1-C24 Drive Un-P1-C24-D1 Drive Un-P1-C24-D2 Drive Un-P1-C24-D3...
  • Page 140 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Drive Un-P1-C30-D1 Drive Un-P1-C30-D2 Drive Un-P1-C30-D3 Drive Un-P1-C30-D4 Carrier Un-P1-C31 Drive Un-P1-C31-D1 Drive Un-P1-C31-D2 Drive Un-P1-C31-D3 Drive Un-P1-C31-D4 Carrier Un-P1-C32 Drive Un-P1-C32-D1 Drive Un-P1-C32-D2 Drive Un-P1-C32-D3...
  • Page 141 Table 30. Bulk power assembly (BPA) locations and failing components (continued) Failing item name Physical location code Drive Un-P1-C46-D1 Drive Un-P1-C46-D2 Drive Un-P1-C46-D3 Drive Un-P1-C46-D4 Carrier Un-P1-C47 Drive Un-P1-C47-D1 Drive Un-P1-C47-D2 Drive Un-P1-C47-D3 Drive Un-P1-C47-D4 Carrier Un-P1-C48 Drive Un-P1-C48-D1 Drive Un-P1-C48-D2 Drive Un-P1-C48-D3...
  • Page 142: 5786, 5787, 7031-D24, And 7031-T24

    Related reference: “9125-F2C system parts” on page 275 Indexed drawings show system part numbers of each part. Related information: Removing and replacing parts 5786, 5787, 7031-D24, and 7031-T24 The information provided in this topic defines specific sections of a location code string. Use this information to understand the meaning of a location code.
  • Page 143 v If the location code begins with UTMPx, the expansion I/O unit's machine type, model number and serial number have not been set yet and this is a temporary unit identifier. To identify the unit, do the following: 1. Examine the display panels on all of the I/O enclosures that are connected to the server until you find one with the same characters in the first 5 digits of the top line in the enclosure's display.
  • Page 144 To review a list of location codes for your I/O enclosure, refer to “5786, 5787, 7031-D24, and 7031-T24” on page 130. Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 145: 5786, 5787, 7031-D24, And 7031-T24 Locations

    Table 33. Prefixes of location code labels for I/O enclosure and system units (continued) Prefix Description Example Port System unit or enclosure integrated connector Unit Usually consists of the machine type Virtual planar Worldwide unique ID This group of digits follows the resource code labels and always begins with the letter W Electronic industries alliance (EIA) spacing value Standardized unit of measure used to identify the...
  • Page 146 Figure 48. I/O enclosure (drawer model, front) or (stand-alone model on its side, front) Figure 49. I/O enclosure (drawer model, back) Finding parts, locations, and addresses...
  • Page 147 Figure 50. I/O enclosure (stand-alone model, back) 7031-T24 Table 34. FRU locations and failing components Failing item removal and replacement Failing item name Physical location code Identify LED procedures Disk drive backplane 1 Un-P1 Disk drive backplane 2 Un-P2 Power distribution backplane Un-P3 Fan 1 (left) Un-A1...
  • Page 148 Table 34. FRU locations and failing components (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures SCSI repeater card 1 (upper Un-C2 See SCSI repeater left) card. SCSI repeater card 2 (upper Un-C3 right) SCSI repeater card 3 (lower Un-C4 left)
  • Page 149: 5796 And 7314-G30

    Table 34. FRU locations and failing components (continued) Failing item removal and replacement Failing item name Physical location code Identify LED procedures Disk drive 1 (back) Un-P2-D01 (logical location Un-Px- See Disk drives. Ty-L5-L0 - single or Un-Px-Ty-L13-L0 - dual Disk drive 2 (back) Un-P2-D02 (logical location Un-Px- Ty-L4-L0 - single or Un-Px-Ty-L12-L0 -...
  • Page 150 Using location codes Use the following table to link to a specific topic that you need additional information on when reading your location code. Table 35. Location code topics Location code topics Description “Location code overview” Contains background information on the use of location codes.
  • Page 151 Physical location codes Physical location codes provide a mapping of logical functions and components (such as backplanes, removable modules, connectors, ports, cables, and devices) to their specific locations within the physical structure of the server. Logical location codes If the physical location cannot be mapped to a physical location code, the server's firmware generates a logical location code.
  • Page 152: 5796 And 7314-G30 Locations

    Another example follows:, Un-P1-C9 is a dual in-line memory module (DIMM), with memory DIMM (C9) plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 153 Figure 51. Rear view of unit. Figure 52. Front view of unit. The following table provides location codes for parts that comprise the server. Table 38. FRU locations and failing components Failing item name Symbolic failing item Physical location code Identify LED Failing item name...
  • Page 154: 5802 And 5877

    Table 38. FRU locations and failing components (continued) Failing item name Symbolic failing item Physical location code Identify LED Failing item name removal and replacement procedures Power supply 1, from Un-E1 See Power front view it is left supply. Power supply 2, from Un-E2 front view it is right Backplane...
  • Page 155 Location code topics that might be of interest Description “Location code format” on page 144 Provides descriptive information of the Un value in the location code string. For example U5886.001. “Location code labels” on page 145 Provides a table that identifies and defines the location code labels.
  • Page 156 Another example follows:, Un-P1-C9 is a memory DIMM, with memory DIMM (C9) plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 157: 5802 And 5877 Locations

    Location code labels The location code label represents a physical part of the server. The following table describes the prefixes of location code labels. Note: These labels apply to system units only. Table 40. Prefixes of location code labels for system units Prefix Description Example...
  • Page 158 Figure 53. 5802 front view Figure 54. 5802 rear view Figure 55. 5877 front view Finding parts, locations, and addresses...
  • Page 159 Figure 56. 5877 rear view The following table provides location codes for parts that make up the server. Table 41. Bulk power assembly (BPA) locations, and failing components Failing item name Symbolic FRU CCIN Failing item removal and name replacement procedures Ux-E1 2C43 OCA UPIC connector...
  • Page 160 Table 41. Bulk power assembly (BPA) locations, and failing components (continued) Failing item name Symbolic FRU CCIN Failing item removal and name replacement procedures Ux-P1-C10 IB riser port Ux-P1-T1 IB riser port Ux-P1-T2 EMC card Enclosure management Ux-P2 50A6 See EMC card. controller (EMC) card Ux-P2-T1 SPCN 9 pin D-shell...
  • Page 161: 5803 And 5873

    Table 41. Bulk power assembly (BPA) locations, and failing components (continued) Failing item name Symbolic FRU CCIN Failing item removal and name replacement procedures Media bay connector Ux-P4-T5 Midplane Midplane Ux-P5 50AA Related reference: “5802 and 5877 system parts” on page 294 Indexed drawings show system part numbers.
  • Page 162 If the location code begins with UTMPx, the expansion I/O unit's machine type, model and serial number have not been set yet and this is a temporary unit identifier. To identify the unit, examine the display panels on all of the expansion I/O units connected to the server until you find one with the same characters in the first 5 digits of the top line in the unit's display.
  • Page 163 Another example follows:, Un-P1-C9 is a memory DIMM, with memory DIMM (C9) plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 164: 5803 And 5873 Locations

    Table 43. Prefixes of location code labels for system units (continued) Prefix Description Example Firmware FRU Worldwide unique identifier The location code label for the worldwide unique identifier consists of the prefix W followed by a maximum of 16 uppercase hexadecimal digits with no leading zeros. A location code might not consist of a worldwide unique identifier.
  • Page 165 Figure 58. Rear view The following table provides location codes for parts that make up the server. Table 44. Bulk power assembly (BPA) locations, and failing components Failing item name Symbolic FRU name CCIN Un-E1 2C44 DCA UPIC connector Un-E1-T1 DCA UPIC connector Un-E1-T2 Un-E2...
  • Page 166 Table 44. Bulk power assembly (BPA) locations, and failing components (continued) Failing item name Symbolic FRU name CCIN IOA slot Un-Px-C10 IB Riser Port Un-Px-T1 IB Riser Port Un-Px-T2 DASD DASD backplane Un-P3 50A7 PORT card 1 Un-P3-C1 50A4 PORT card 2 Un-P3-C2 50A4 PORT card 3...
  • Page 167 Table 44. Bulk power assembly (BPA) locations, and failing components (continued) Failing item name Symbolic FRU name CCIN SAS connector Un-P4-T4 Media bay connector Un-P4-T5 Media bay connector Un-P4-T6 Midplane Midplane Un-P5 50A8 5886 The information provided in this topic defines specific sections of a location code string. Use this information to understand the meaning of a location code.
  • Page 168 If the location code begins with UTMPx, the expansion I/O unit's machine type, model and serial number have not been set yet and this is a temporary unit identifier. To identify the unit, examine the display panels on all of the expansion I/O units connected to the server until you find one with the same characters in the first 5 digits of the top line in the unit's display.
  • Page 169 Another example follows:, Un-P1-C9 is a memory DIMM, with memory DIMM (C9) plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 170: 5886 Locations

    Worldwide unique identifier The location code label for the worldwide unique identifier consists of the prefix W followed by a maximum of 16 uppercase hexadecimal digits with no leading zeros. A location code might not consist of a worldwide unique identifier. When present, the worldwide unique identifier location label follows the location label of the resource that interfaces with the resource that has the worldwide unique identifier, usually a port.
  • Page 171 Table 47. FRU locations and failing components (continued) Failing item name Physical location code Identify LED Failing item removal and replacement procedures ESM A Un-C1 See Enclosure services manager. ESM B Un-C2 Power supplies Power supply Un-E1 See Power supply. Power supply Un-E2 Midplane...
  • Page 172 Location code topics that might be of interest Description “Location code labels” on page 161 Provides a table that identifies and defines the location code labels. The location code labels begin with an alphabetic character and follow the system serial number. For example, U7879.001.10ABCDE-P3-C31-T2-L23.
  • Page 173 Another example follows: Un-P1-C9 is a memory DIMM, with memory DIMM (C9) plugged into a backplane (P1), which is inside the unit (Un). Note: For devices, certain error conditions might cause an IBM i device to display the device location in an AIX format.
  • Page 174: 5887 Locations

    Table 49. Prefixes of location code labels for system units Prefix Description Example Air-moving device Fan, blower Card connector IOP, IOA, DIMM, processor card Device Diskette, control panel Electrical Battery, power supply, ac charger Logical path SAS target Integrated drive electronics (IDE) address, Fibre Channel LUN Horizontal placement for an empty rack location Planar...
  • Page 175 Figure 60. Front view Figure 61. Rear view The following table provides location codes for parts that make up the server. Table 50. FRU locations and failing components Failing item name Physical location code Identify LED Failing item removal and replacement procedures System unit Event Services Manager...
  • Page 176: 5888 Or Edr1 Pcie Storage Enclosure

    Table 50. FRU locations and failing components (continued) Failing item name Physical location code Identify LED Failing item removal and replacement procedures Midplane Un-P1 See Removing and installing a midplane. Device physical locations Disk drive 1 Un-P1-D1 See Removing and installing a disk Disk drive 2 Un-P1-D2...
  • Page 177 Location code topics Description “Location code overview” Contains background information on the use of location codes. “Physical location codes” Provides a definition for physical location code. “Logical location codes” on page 166 Provides a definition of what a logical location code is. “Location code format”...
  • Page 178 Logical location codes If the physical location cannot be mapped to a physical location code, the server's firmware generates a logical location code. A logical location code is a sequence of location labels that identifies the path that the system uses to communicate with a given resource. Note: A resource has as many logical location codes as it has logical connections to the system.
  • Page 179: 5888 Or Edr1 Pcie Storage Enclosure Locations

    Location code labels The location code label represents a physical part of the server. The following table describes the prefixes of location code labels. Note: These labels apply to system units only. Table 51. Prefixes of location code labels for system units Prefix Description Example...
  • Page 180 Figure 62. Front and rear view The following table provides location codes for parts of a server. Table 52. FRU locations and failing components Failing item removal and Failing item name Physical location code Fault and identify LED replacement procedures System unit Midplane Midplane...
  • Page 181 Table 52. FRU locations and failing components (continued) Failing item removal and Failing item name Physical location code Fault and identify LED replacement procedures Power supply (left) Un-P1-E1 Fault only (5888 PCIe For 5888 PCIe storage storage enclosure) enclosure, see Removing and installing a power Yes (EDR1 PCIe storage supply.
  • Page 182: Addresses

    Table 52. FRU locations and failing components (continued) Failing item removal and Failing item name Physical location code Fault and identify LED replacement procedures Solid-state drive (SSD) 1 Un-P1-D1 For 5888 PCIe storage enclosure, see Removing SSD 2 Un-P1-D2 and installing a solid-state SSD 3 Un-P1-D3 drive.
  • Page 183: 8202-E4B Or 8205-E6B Addresses

    You can cross-reference a disk drive physical location code to the address. Use the address to find the location for the system, and then go to “8202-E4B or 8205-E6B” on page 3 to find additional location information. Table 53. IOA and device address information running IBM i Position Possible failing item...
  • Page 184: 8202-E4C, 8202-E4D, 8205-E6C, Or 8205-E6D Addresses

    Use the address to find the location for the system, and then go to “8202-E4C, 8202-E4D, 8205-E6C, or 8205-E6D” on page 15 to find additional location information. Table 54. IOA and device address information running IBM i Position Possible failing item...
  • Page 185: 8231-E2B Addresses

    8231-E2B addresses You can cross-reference a disk drive physical location code to the address. Use the address to find the location for the system, and then go to “8231-E2B” on page 26 to find additional location information. Table 55. IOA and device address information Position Possible failing item DSA (BBBBCcbb)
  • Page 186: 8233-E8B And 8236-E8C Addresses

    You can cross-reference a disk drive physical location code to the address. Use the address to find the location for the system, and then go to “8233-E8B and 8236-E8C” on page 44 to find additional location information. Table 57. IOA, and device address information, running IBM i Position Possible failing item...
  • Page 187: 8408-E8D Or 9109-Rmd Addresses

    Table 57. IOA, and device address information, running IBM i (continued) Position Possible failing item DSA (BBBBCcbb) Unit address Un -P1-C2 PCI-E adapter 02050000 Not applicable Un -P1-C3 PCI-E adapter 02070000 Not applicable Un -P1-C4 PCI-X adapter 02021000 Not applicable...
  • Page 188: 9117-Mmb And 9179-Mhb Addresses

    Table 58. IOA and device address information for running IBM i (continued) Position Possible failing item Direct select address (DSA) (BBBBCcbb) Unit address Un-P2-C9-D3 Disk drive 3 02080000 or 02090000 000000FF Un-P2-C9-D4 Disk drive 4 02080000 or 02090000 000500FF Un-P2-C9-D5...
  • Page 189 Table 59. IOA, and device address information for running IBM i (continued) Position Possible failing item DSA (BBBBCcbb) Unit address Un -P2-C5 PCI adapter 0202-10-00 (primary) Not applicable 0222-10-00 (secondary 1) 0242-10-00 (secondary 2) 0262-10-00 (secondary 3) Un -P2-C6 PCI adapter...
  • Page 190: 8412-Ead, 9117-Mmc, 9117-Mmd, 9179-Mhc, Or 9179-Mhd Addresses

    Table 59. IOA, and device address information for running IBM i (continued) Position Possible failing item DSA (BBBBCcbb) Unit address Un-P2-C9-D7 IDE drive 1 0200-20-00 (primary) 000000FF 0220-20-00 (secondary 1) 0240-20-00 (secondary 2) 0260-20-00 (secondary 3) 8412-EAD, 9117-MMC, 9117-MMD, 9179-MHC, or 9179-MHD addresses You can cross-reference a disk drive physical location code to the address.
  • Page 191 Table 60. IOA and device address information for running IBM i (continued) Position Possible failing item DSA (BBBBCcbb) Unit address Un-P2-C5 PCI adapter 0202-10-00 (primary) Not applicable 0222-10-00 (secondary 1) 0242-10-00 (secondary 2) 0262-10-00 (secondary 3) Un-P2-C6 PCI adapter 0207-00-00 (primary)
  • Page 192: 5786, 5787, 7031-D24, And 7031-T24 Addresses

    Table 60. IOA and device address information for running IBM i (continued) Position Possible failing item DSA (BBBBCcbb) Unit address Un-P2-C9-D7 Serial Advanced 0200-20-00 (primary) 000000FF Technology Attachment 0220-20-00 (secondary 1) (SATA) drive 1 0240-20-00 (secondary 2) 0260-20-00 (secondary 3) 5786, 5787, 7031-D24, and 7031-T24 addresses Use the table to cross reference a disk drive physical location code to that of the SCSI cable address.
  • Page 193: 5796 And 7314-G30 Addresses

    You can cross-reference a disk drive physical location code to the address. Use the address to find the location for the system, then go to “5802 and 5877” on page 142 to find additional location information. Table 63. IOA, and device address information, running IBM i Position Possible failing item...
  • Page 194: 5803 And 5873 Addresses

    Table 63. IOA, and device address information, running IBM i (continued) Position Possible failing item DSA (BBBBCcbb) Unit address Ux-P3-D8 DASD drive 8 (5802 The disk unit has the same DSA as the 000D00FF or 040D00FF only) storage IOA controlling it.
  • Page 195 Table 64. IOA, and device address information, running IBM i (continued) Position Possible failing item DSA (BBBBCcbb) Unit address Un-P3-D3 DASD drive 3 (5803 The disk unit has the same DSA as the 000800FF or 040800FF only) storage IOA controlling it.
  • Page 196: 5886 Addresses

    Table 64. IOA, and device address information, running IBM i (continued) Position Possible failing item DSA (BBBBCcbb) Unit address Un-P3-D26 DASD drive 26 (5803 The disk unit has the same DSA as the 001200FF or 041200FF only) storage IOA controlling it.
  • Page 197: 5888 Or Edr1 Pcie Storage Enclosure Addresses

    Table 66. Device address information (continued) Physical location code Unit address Un-P1-D7 0x0600FF or 00xx06FF Un-P1-D8 0x0700FF or 00xx07FF Un-P1-D9 0x0800FF or 00xx08FF Un-P1-D10 0x0900FF or 00xx09FF Un-P1-D11 0x0A00FF or 00xx0AFF Un-P1-D12 0x0B00FF or 00xx0BFF Un-P1-D13 0x0C00FF or 00xx0CFF Un-P1-D14 0x0D00FF or 00xx0DFF Un-P1-D15 0x0E00FF or 00xx0EFF...
  • Page 198: System Parts

    Table 67. Device address information (continued) Physical location code Unit address Un-P1-D13 0x0C00FF Un-P1-D14 0x0D00FF Un-P1-D15 0x0E00FF Un-P1-D16 0x0F00FF Un-P1-D17 0x1000FF Un-P1-D18 0x1100FF Un-P1-D19 0x1200FF Un-P1-D20 0x1300FF Un-P1-D21 0x1400FF Un-P1-D22 0x1500FF Un-P1-D23 0x1600FF Un-P1-D24 0x1700FF Un-P1-D25 0x1800FF Un-P1-D26 0x1900FF Un-P1-D27 0x1A00FF Un-P1-D28 0x1B00FF...
  • Page 199 Rack final assembly Table 68. Cover assembly part numbers Index CCIN Part number Units per Description number assembly 46K5096 EIA bracket (left) 46K5097 EIA bracket (right) 09P3744 Attaching screw for EIA bracket 59Y4919 Slide rail assembly 49Y5312 Attaching screw for slide rail assembly 74Y7445 Top access cover assembly 59Y4822...
  • Page 200 Stand-alone final assembly Table 69. Stand-alone assembly part numbers Index CCIN Part number Units per Description number assembly 46K4642 Side cover (left) 74Y5228 Left side cover (OEM) Service access cover 74Y4942 Top handle cap 74Y4941 Top handle assembly 46K4641 Side cover (right) Attaching screw for side cover (right) Finding parts, locations, and addresses...
  • Page 201 System assembly detail Table 70. System assembly part numbers Index CCIN Part number Units per Description number assembly 2BCD 74Y5481 Control panel assembly 46K4646 Control panel cable (rack) 46K4645 Control panel cable (stand-alone) 74Y6301 Fan cage assembly 74Y5220 120 mm fan assembly Tape drive.
  • Page 202 Table 70. System assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 266F 74Y2003 Host Ethernet Adapter Dual 10 Gb copper card 5288 74Y2094 PCIe2 2-port 10 GbE copper card 5287 74Y2095 PCIe2 2-port 10 GbE fiber card 46K5029 External SAS cable assembly 46K5415...
  • Page 203 System assembly detail, continued Table 71. System assembly part numbers Index CCIN Part number Units per Description number assembly 537B 74Y6151 8 core 3.0 GHz processor module (8202-E4B) 537C 74Y6150 6 core 3.0 GHz processor module (8202-E4B) 537D 74Y6149 4 core 3.0 GHz processor module (8202-E4B) 539E 74Y6155 4 core 3.72 GHz processor module (8205-E6B)
  • Page 204 Table 71. System assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 74Y5985 Power supply assembly 74Y6714 Interlock switch with cable 2BFB 46K7505 System backplane (8205-E6B) 2BFC 46K7877 System backplane (8202-E4B) Attaching screw for system backplane Memory card assembly Table 72.
  • Page 205 Table 73. Cables (continued) Feature code Description Part number 3124 3.7-meter cable 88G4771 3125 8-meter cable 88G4772 3652 1-meter SAS EE cable 44V4147 3653 3-meter SAS EE cable 44V4148 3654 6-meter SAS EE cable 44V4149 3661 3-meter SAS X cable 44V4154 3662 6-meter SAS X cable...
  • Page 206: 8202-E4C, 8202-E4D, 8205-E6C, Or 8205-E6D System Parts

    Attaching screw for EIA bracket 00E5669 Slide rail assembly 49Y5312 Attaching screw for slide rail assembly 74Y9017 Top access cover assembly (IBM) 74Y9018 Top access cover assembly (OEM) 68Y7211 Cable management arm assembly 46K4640 Front bezel (8202-E4C or 8202-E4D) (rack)
  • Page 207 Table 75. Cover assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 74Y4858 Front bezel (OEM) (stand-alone) System assembly detail Table 76. System assembly part numbers Index CCIN Part number Units per Description number assembly 2BCD 74Y3964 Control panel assembly 46K4646...
  • Page 208 Table 76. System assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 2B50 00E7160 Processor VRM (8205-E6C and 8205-E6D) 51CE 00E7162 Processor VRM (low wattage) (8202-E4C and 8202-E4D) 2C1E 00E2822 GX adapter 2BDA 00E0646 GX adapter 46K5415 Air divider 46K5417...
  • Page 209 System assembly detail, continued Table 77. System assembly part numbers Index CCIN Part number Units per Description number assembly 543E 74Y8586 8 core 3.0 GHz processor module (8202-E4C) 543F 74Y8583 6 core 3.0 GHz processor module (8202-E4C) 544A 74Y8580 4 core 3.0 GHz processor module (8202-E4C) 543C 74Y8598 1 - 2...
  • Page 210 Table 77. System assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 52DB 00E0942 System VPD card (8202-E4C or 8205-E6C) 521E 00E1672 System VPD card (8202-E4D or 8205-E6D) 2B46 00E7187 Power supply assembly (8202-E4C or 8205-E6C) 2BED 00E7237 Power supply assembly (8202-E4D or 8205-E6D)
  • Page 211 Table 78. Memory card assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 31FB 78P1915 1 - 32 16 GB, 1066 MHz DDR3 DIMM (8202-E4D or 8205-E6D) 31F7 78P1539 1 - 32 32 GB, 1066 MHz DDR3 DIMM (8202-E4D or 8205-E6D) 2C1C 00E0638...
  • Page 212: Disk Drive And Solid-State Drive System Parts

    00LY323* 775 GB (528 block size) small form factor solid-state SAS drive 198B 00E6165* 69 GB 15K small form factor SAS disk drive (IBM i) 44V4429** 6600 42R8391** 73 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 213 00E9972* 300 GB 15K small form factor SAS disk drive (AIX and Linux) 19A3 74Y4897* 571 GB 10K small form factor SAS disk drive (IBM i) 59CE 00E8648* 571 GB 15K small form factor SAS disk drive (IBM i) 59E4...
  • Page 214 00LY328* 775 GB (528 block size) small form factor solid-state SAS drive 19B0 00E6171* 139 GB 15K small form factor SAS disk drive (IBM i) 46K4804** 19B0 00E6173* 146 GB 15K small form factor SAS disk drive (AIX and Linux)
  • Page 215: Keyboard Parts

    **Not designed to comply with RoHS requirement Keyboard parts Keyboard parts information. Table 85. Keyboard parts Description Part number Keyboard, Arabic 10N9442 Keyboard, Belgium, and UK 10N9427 Keyboard, Brazilian Portuguese 10N9421 Keyboard, Bulgaria 10N9430 Keyboard, China 10N9424 Keyboard, Czechoslovakian 10N9439 Keyboard, Danish 10N9429 Keyboard, Dutch...
  • Page 216: 8231-E2B System Parts

    8231-E2B system parts Indexed drawings show system part numbers of each part. Rack final assembly Table 86. Rack assembly part numbers Index CCIN Part number Units per Description number assembly 74Y5193 EIA bracket (left) 39J0199 Attaching screw for EIA bracket (left) 59Y4919 Slide rail assembly 74Y7446...
  • Page 217 387 GB small form factor solid-state SAS drive 19A3 74Y4897 1-6 or 1-3 571 GB 10K small form factor SAS disk drive (IBM i) 74Y4900 1-6 or 1-3 600 GB 10K small form factor SAS disk drive Finding parts, locations, and addresses...
  • Page 218 19A4 74Y9271 1-6 or 1-3 857 GB 10K small form factor SAS disk drive (IBM i) 74Y9272 1-6 or 1-3 900 GB 10K small form factor SAS disk drive 2BE7 74Y2024 Disk drive backplane (supports three disk drives...
  • Page 219 Rack assembly detail, continued Table 88. Rack assembly part numbers Index CCIN Part number Units per Description number assembly 74Y6275 Fan cage assembly (front) Memory card cage assembly Attaching screw for memory card cage assembly VRM bracket (left) Attaching screw for VRM bracket (left) Divider VRM guide (right) Attaching screw, VRM guide (right)
  • Page 220 2D1E 74Y2022 Interposer card assembly 74Y7205 Interlock switch ® 74Y5197 Front Bezel (IBM Power 710 Express) 74Y5198 Front Bezel (IBM Power 730 Express) 74Y5199 Front Bezel (OEM) Table 89. Cables Feature code Description Part number 3124 3.7-meter cable 88G4771 3125...
  • Page 221: 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, Or 8268-E1D System Parts

    Table 90. Miscellaneous parts (continued) CCIN Description Part number Removable media See Managing devices. PCI adapters See Managing PCI adapters. 58B2 1.8-inch 177 GB small form factor solid-state drive on PCIe SAS 43W7749 RAID and SSD adapter Cache battery pack for cache battery card and RAID and cache 74Y6773 storage controller Cable configuration...
  • Page 222 Table 91. Rack assembly part numbers Index CCIN Part number Units per Description number assembly 74Y5193 EIA bracket (left) 90P1959 Attaching screw for EIA bracket (left) 00E5669 Rail kit (includes two slides) 74Y9068 Top access cover assembly 74Y9063 Cable management arm assembly 74Y5194 EIA bracket (right) 90P1959...
  • Page 223 Table 92. Rack assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 2BD7 74Y3352 Disk drive and media backplane (supports six disk drives and one DVD drive) 6B1E 74Y5222 60 mm fan assembly 2BE3 00E0635 1 - 4 Memory card assembly 31F8 78P1011...
  • Page 224 Rack assembly detail, continued Table 93. Rack assembly part numbers Index CCIN Part number Units per Description number assembly 74Y3353 Fan cage assembly (front) 52DC 00E0940 System VPD card (8231-E1C or 8231-E2C) 521F 00E1674 System VPD card (8231-E1D, 8231-E2D, or 8268-E1D) 2B4B 00E1765...
  • Page 225 Table 93. Rack assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 54AF 00E7469 1 - 2 8- core 3.61 GHz processor module (only 8231-E2D) 54AC 00E7470 1 - 2 6 core 4.28 GHz processor module (only 8231-E1D, 8231-E2D, or 8268-E1D) 54AB 00E7472...
  • Page 226: Disk Drive And Solid-State Drive System Parts

    00LY323* 775 GB (528 block size) small form factor solid-state SAS drive 198B 00E6165* 69 GB 15K small form factor SAS disk drive (IBM i) 44V4429** 6600 42R8391** 73 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 227 00E9972* 300 GB 15K small form factor SAS disk drive (AIX and Linux) 19A3 74Y4897* 571 GB 10K small form factor SAS disk drive (IBM i) 59CE 00E8648* 571 GB 15K small form factor SAS disk drive (IBM i) 59E4...
  • Page 228 00LY328* 775 GB (528 block size) small form factor solid-state SAS drive 19B0 00E6171* 139 GB 15K small form factor SAS disk drive (IBM i) 46K4804** 19B0 00E6173* 146 GB 15K small form factor SAS disk drive (AIX and Linux)
  • Page 229: Keyboard Parts

    Keyboard parts Keyboard parts information. Table 100. Keyboard parts Description Part number Keyboard, Arabic 10N9442 Keyboard, Belgium, and UK 10N9427 Keyboard, Brazilian Portuguese 10N9421 Keyboard, Bulgaria 10N9430 Keyboard, China 10N9424 Keyboard, Czechoslovakian 10N9439 Keyboard, Danish 10N9429 Keyboard, Dutch 10N9433 Keyboard, French 10N9415 Keyboard, French Canadian 10N9425...
  • Page 230 Rack final assembly Table 101. Rack final assembly part numbers Index CCIN Part number Units per Description number assembly 44V4790 Left rack mounting bracket 09P3744 Screw 44V3349 Left rail 46K5086 Rack top cover 44V3352 Right rail 44V4793 Right rack mounting bracket 09P3744 Screw 46K5453...
  • Page 231 Rack assembly detail Table 102. Rack assembly detail part numbers Index CCIN Part number Units per Description number assembly 2A16 74Y2244 Media backplane 58B8 74Y9524 387 GB small form factor solid-state SAS (Gen1) drive 58B9 74Y9526 387 GB small form factor solid-state SAS (Gen2) drive 58B0 44V6821...
  • Page 232 44V6833 300 GB 10 K small form factor SAS disk drive 19A3 74Y4897 571 GB 10K small form factor SAS disk drive (IBM i) 74Y4900 600 GB 10K small form factor SAS disk drive 19A4 74Y9271 857 GB 10K small form factor SAS disk drive...
  • Page 233 Table 103. Rack assembly detail, continued part numbers Index CCIN Part number Units per Description number assembly 44V3776 PCI divider 44V3298 RAID base card 46K6109 RAID cache card 74Y5667 RAID cache card battery 46Y3513 TPMD card 1817 46K6564 GX IB 12x adapter 45D3912 GX IB 12x adapter 52B4...
  • Page 234 Rack assembly detail, continued Table 104. Rack assembly detail part numbers Index CCIN Part number Units per Description number assembly 44V3458 AC line cord box NONUM Fan cage 44V3455 Fan lattice 44V3454 530D 74Y1833 8 core 3.55 GHz processor card assembly (8233-E8B) 530E 74Y1845...
  • Page 235 Units per Description number assembly 538B 74Y2453 8 core 3.3 GHz processor card assembly (8233-E8B and 8236-E8C) Note: See the IBM Prerequisite Web site at http://www-912.ibm.com/e_dir/ eServerPrereq.nsf for minimum system firmware requirements. 538C 74Y2457 8 core 3.0 GHz processor card assembly...
  • Page 236 Rack assembly detail, continued Table 105. Rack assembly detail part numbers Index CCIN Part number Units per Description number assembly 74Y1825 System backplane NONUM Backplane screw NONUM Front processor support NONUM Screw NONUM Card support divider NONUM Screw 42R5751 SAS cable, Disk drive backplane to bulkhead connector (external) 44V5252 SAS cable, Disk drive backplane to bulkhead...
  • Page 237 Rack assembly detail, continued Table 106. Rack assembly detail part numbers, continued. Index CCIN Part number Units per Description number assembly DIMM duct plate Note: The DIMM duct plate is part of the processor card assembly FRU and cannot be ordered separately.
  • Page 238 Table 106. Rack assembly detail part numbers, continued. (continued) Index CCIN Part number Units per Description number assembly 2A2C 46K6300 Processor voltage regulator 30 A Table 107. Cables CCIN/CIN Description Part number 0.6 meter InfiniBand cable 42V2129 1 meter SAS cable 44V4147 1.5 meter GX Dual-Port 12X Channel Attach adapter to GX cable 15R8139...
  • Page 239: 8248-L4T, 8408-E8D, Or 9109-Rmd System Parts

    Table 108. Miscellaneous parts (continued) CCIN Description Part number PCI adapters See Managing PCI adapters. 52B6 VPD card (8233-E8B) 46K6943 52CB VPD card (8236-E8C) 46K8089 Wrap plug 12R9314 Wrap plug 03N6070 Wrap plug 87H3439 Wrap plug 87H3442 Wrap plug 93H5270 Wrap plug 87H3588 Wrap plug...
  • Page 240 Cover assemblies Table 109. Cover assembly part numbers Index CCIN Part number Units per Description number assembly 00FW143 Front cover assembly (8248-L4T only) 00E6545 Front cover assembly (8408-E8D only) 00E8047 Front cover assembly (9109-RMD only) 00E7085 Front cover assembly (OEM) 46K6362 Rack rail kit Finding parts, locations, and addresses...
  • Page 241 Final assembly (front) Table 110. Final assembly (front) Index CCIN Part number Units per Description number assembly 00E7691 Fan assembly (single fan) 2B61 00E1385 System processor assembly 2B62 00E0957 Midplane 00E8717 System processor assembly guide rail kit 00E6658 Midplane light pipe 2BBE 00E7753 Small form factor SAS disk drive backplane with...
  • Page 242 Table 110. Final assembly (front) (continued) Index CCIN Part number Units per Description number assembly 2BC2 00E5681 175 MB cache RAID and dual storage IOA enablement card Note: If feature code 5662 is installed, the embedded SAS adapters report CCINs of 57CF. 1 - 6 See Disk drive and solid-state drive system parts.
  • Page 243 Table 111. Final assembly part numbers (rear) (continued) Index CCIN Part number Units per Description number assembly 2B56 00E0778 Twinaxial - 2 x 1 GbE and 2 x 10 GbE integrated multifunction card 2C4D 74Y3843 Optical - 2 x 10 GbE and 2 x 10 GbE integrated multifunction card 2C4C 74Y3832...
  • Page 244 Final assembly Finding parts, locations, and addresses...
  • Page 245: Disk Drive And Solid-State Drive System Parts

    Table 112. Final assembly part numbers Index CCIN Part number Units per Description number assembly 54A1 00E8721 1 - 4 8 core 3.50 GHz processor card FRU kit (8408-E8D or 8248-L4T only) 54A3 00E8720 1 - 4 8 core 4.06 GHz processor card FRU kit (8408-E8D or 8248-L4T only) 548C 00E8718...
  • Page 246 00LY323* 775 GB (528 block size) small form factor solid-state SAS drive 198B 00E6165* 69 GB 15K small form factor SAS disk drive (IBM i) 44V4429** 6600 42R8391** 73 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 247 00LY328* 775 GB (528 block size) small form factor solid-state SAS drive 19B0 00E6171* 139 GB 15K small form factor SAS disk drive (IBM i) 46K4804** 19B0 00E6173* 146 GB 15K small form factor SAS disk drive (AIX and Linux)
  • Page 248: Keyboard Parts

    00E8689* 600 GB 15K small form factor SAS disk drive (AIX and Linux) 19B4 74Y9285* 857 GB 10K small form factor SAS disk drive (IBM i) 19B4 74Y9286* 900 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 249: Wrap Plug Parts

    Table 118. Keyboard parts (continued) Description Part number Keyboard, Italian 10N9416 Keyboard, Japanese 10N9420 Keyboard, Korea 10N9423 Keyboard, Latin American (Spanish) 10N9441 Keyboard, Norwegian 10N9432 Keyboard, Portuguese 10N9434 Keyboard, Polish 10N9437 Keyboard, Russian 10N9444 Keyboard, Slovak 10N9438 Keyboard, Slovenia 10N9445 Keyboard, Spanish 10N9419 Keyboard, Sweden, and Finland...
  • Page 250 Cover assemblies Table 120. Cover assembly part numbers Index CCIN Part number Units per Description number assembly 44V7403 Front cover assembly (9117-MMB) 46K6220 Front cover assembly (9179-MHB) 46K6362 Rack rail kit 46K5179 FSP cover plate Finding parts, locations, and addresses...
  • Page 251 Final assembly (front) Table 121. Final assembly (front) Index CCIN Part number Units per Description number assembly 46K4939 Fan assembly (single fan) 497B 74Y5976 System processor assembly FRU kit (9117-MMB and 9179-MHB) 74Y1747 Mid-plane 46K4625 Mid-plane light pipe 2BBE 74Y5511 Small form factor SAS disk drive backplane with embedded SAS adapters Note: If feature code 5662 is not installed, the...
  • Page 252 Table 121. Final assembly (front) (continued) Index CCIN Part number Units per Description number assembly 2BC2 74Y6441 175 MB cache RAID and dual storage IOA enablement card Note: If feature code 5662 is installed the embedded SAS adapters report CCINs of 57CF. 1 - 6 See Disk drive and solid-state drive system parts.
  • Page 253 Finding parts, locations, and addresses...
  • Page 254 Table 122. Final assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 536C 74Y4915 6 core 3.5 GHz processor card FRU kit (9117-MMB) 536D 74Y4914 8 core 3.1 GHz processor card FRU kit (9117-MMB) 536E 74Y4913 8 core 3.86 GHz processor card FRU kit (9179-MHB) 2BC7...
  • Page 255 Table 123. Assembly Index CCIN Part number Units per Description number assembly 2BC3 45D7063 IO Hub 12X adapter card 74Y4926 Power supply 1725 W 52B7 46K8127 VPD card 2BC4 46K5965 4 x 1 GbE Host Ethernet Adapter card 2BDC 46K5538 Optical - 2 x 1 GbE and 2 x 10 GbE Host Ethernet Adapter card 2BC6...
  • Page 256: Disk Drive And Solid-State Drive System Parts

    00LY323* 775 GB (528 block size) small form factor solid-state SAS drive 198B 00E6165* 69 GB 15K small form factor SAS disk drive (IBM i) 44V4429** 6600 42R8391** 73 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 257 00E9974* 600 GB 15K small form factor SAS disk drive (AIX and Linux) 19A4 74Y9271* 857 GB 10K small form factor SAS disk drive (IBM i) 19A4 74Y9272* 900 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 258: Keyboard Parts

    Table 128. 5887 disk drive and solid-state drive system parts (continued) CCIN Part number Description 19B1 74Y6497* 283 GB 15K small form factor SAS disk drive (IBM i) 19B1 74Y6498* 300 GB 15K small form factor SAS disk drive (AIX and Linux) 19B7 00E6170*...
  • Page 259 Table 130. Keyboard parts (continued) Description Part number Keyboard, Brazilian Portuguese 10N9421 Keyboard, Bulgaria 10N9430 Keyboard, China 10N9424 Keyboard, Czechoslovakian 10N9439 Keyboard, Danish 10N9429 Keyboard, Dutch 10N9433 Keyboard, French 10N9415 Keyboard, French Canadian 10N9425 Keyboard, German/Austrian 10N9417 Keyboard, Greek 10N9435 Keyboard, Hebrew 10N9436 Keyboard, Hungarian...
  • Page 260: Wrap Plug Parts

    Wrap plug parts Wrap plug information. Table 131. Wrap plug Description Part number Wrap plug 12R9314 12R9315 42R4761 6165899 73H2508 87H3311 87H3439 87H3442 93H5270 03N6070 8412-EAD, 9117-MMC, 9117-MMD, 9179-MHC, or 9179-MHD system parts Indexed drawings show system part numbers. Note: When upgrading, make sure that the Dual inline memory module (DIMM) is compatible with the firmware level of the system.
  • Page 261 Cover assemblies Table 132. Cover assembly part numbers Index CCIN Part number Units per Description number assembly 00FW205 Front cover assembly (8412-EAD) 74Y9542 Front cover assembly (9117-MMC and 9117-MMD) 74Y9543 Front cover assembly (9179-MHC and 9179-MHD) 74Y9544 Front cover assembly (OEM) 00J0038 ESD shield assembly 46K6362...
  • Page 262 Final assembly (9117-MMC or 9179-MHC with two-processor system unit) Table 133. Final assembly (front) Index CCIN Part number Units per Description number assembly 74Y9391 Fan assembly (single fan) 497B 00E0699 System processor assembly FRU kit (9117-MMC and 9179-MHC with two-processor system unit) 2BBD 74Y3890 Mid-plane...
  • Page 263 Table 133. Final assembly (front) (continued) Index CCIN Part number Units per Description number assembly 2BC2 00E5681 175 MB cache RAID and dual storage IOA enablement card Note: If feature code 5662 is installed, the embedded SAS adapters report CCINs of 57CF. See Disk drive and solid-state drive system parts.
  • Page 264 Table 134. Final assembly (front) (continued) Index CCIN Part number Units per Description number assembly 2BBE 74Y9514 Small form factor SAS disk drive backplane with embedded SAS adapters Note: If feature code 5662 is not installed, the embedded SAS adapters report CCINs of 57C7. If feature code 5662 is installed, the embedded SAS adapters report CCINs of 57CF.
  • Page 265 Final assembly (9117-MMC or 9179-MHC with two-processor system unit) Finding parts, locations, and addresses...
  • Page 266 Table 135. Final assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 544C 74Y8855 6 core 3.724 GHz processor card FRU kit (9117-MMC) 544E 74Y8860 8 core 3.304 GHz processor card FRU kit (9117-MMC) 544B 74Y8865 8 core 3.920 GHz processor card FRU kit (9179-MHC with two-processor system unit) 2BC7...
  • Page 267 Final assembly (8412-EAD, 9117-MMD, 9179-MHC with four-processor system unit, or 9179-MHD) Finding parts, locations, and addresses...
  • Page 268 Table 136. Final assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 53A5 74Y9242 6 core 3.444 GHz processor card FRU kit (9179-MHC four-processor system unit) AAF4 00E7180 3 core 4.228 GHz processor card FRU kit (8412-EAD, 9117-MMD, or 9179-MHD) AAF6 00E7181...
  • Page 269 Final assembly (rear) Table 137. Assembly Index CCIN Part number Units per Description number assembly 2BC3 74Y0532 I/O hub 12X adapter card 2B94 00E1457 GX++ 2-port PCIe2 x8 adapter 2BED 00J0439 Power supply 1925 W 560B 00E3232 VPD card (8412-EAD) 52CF 00E0944 VPD card (9117-MMC or 9179-MHC)
  • Page 270: Disk Drive And Solid-State Drive System Parts

    Table 137. Assembly (continued) Index CCIN Part number Units per Description number assembly 2BBB 00E1662 FSP card (drawers 1 and 2) (8412-EAD, 9117-MMD, or 9179-MHD) 2BBC 74Y2861 FSP Passthru card (drawers 3 and 4) Table 138. Cables Description Part number SMP cable 1 (outer left - outer left, span two drawers) 74Y7525 SMP cable 2 (outer right - outer right, span two drawers)
  • Page 271 00LY323* 775 GB (528 block size) small form factor solid-state SAS drive 198B 00E6165* 69 GB 15K small form factor SAS disk drive (IBM i) 44V4429** 6600 42R8391** 73 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 272 00LY328* 775 GB (528 block size) small form factor solid-state SAS drive 19B0 00E6171* 139 GB 15K small form factor SAS disk drive (IBM i) 46K4804** 19B0 00E6173* 146 GB 15K small form factor SAS disk drive (AIX and Linux)
  • Page 273: Keyboard Parts

    00E8689* 600 GB 15K small form factor SAS disk drive (AIX and Linux) 19B4 74Y9285* 857 GB 10K small form factor SAS disk drive (IBM i) 19B4 74Y9286* 900 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 274: Wrap Plug Parts

    Table 144. Keyboard parts (continued) Description Part number Keyboard, Italian 10N9416 Keyboard, Japanese 10N9420 Keyboard, Korea 10N9423 Keyboard, Latin American (Spanish) 10N9441 Keyboard, Norwegian 10N9432 Keyboard, Portuguese 10N9434 Keyboard, Polish 10N9437 Keyboard, Russian 10N9444 Keyboard, Slovak 10N9438 Keyboard, Slovenia 10N9445 Keyboard, Spanish 10N9419 Keyboard, Sweden, and Finland...
  • Page 275: 9119-Fhb System Parts

    9119-FHB system parts Indexed drawings show system part numbers of each part. Table 146. Final assembly (assembly 1) Index number CCIN Part number Units Description 45D3406 Cover assembly (left) Finding parts, locations, and addresses...
  • Page 276 Table 146. Final assembly (assembly 1) (continued) Index number CCIN Part number Units Description 2665528 Screw 42V2119 J-bracket assembly, side cover 2665528 Screw 45D4167 Acoustic rear cover 45D3405 Cover assembly (right) 2665528 Screw 2665525 Screw 41V2376 Latch bracket 45D7950 Acoustic front cover Table 147.
  • Page 277 Table 147. Final assembly (assembly 2) (continued) Index number CCIN Part number Units Description 77G0599 Screw 2C34 45D2991 Bulk power hub (BPH) 2C32 41U9484 As required Bulk power distribution (BPD) assembly 31L8609 As required BPD filler assembly 2C19 45D8506 Bulk power controller (BPC) assembly 2C7B 45D7780 As required...
  • Page 278 Table 148. Final assembly (assembly 3) Index number CCIN Part number Units Description 45D5694 Light strip, front 45D2986 Actuator assembly (top and bottom) 45D2965 Node lock assembly Finding parts, locations, and addresses...
  • Page 279 Table 148. Final assembly (assembly 3) (continued) Index number CCIN Part number Units Description 44P2994 As required Filler plate 77G0599 Screw 74F1823 Nut clip 44P2462 As required Filler plate 77G0599 Screw 74F1823 Nut clip 45D9112 Node locking bracket assembly (front) 73Y4218 As required Node assembly, unpopulated...
  • Page 280 Table 149. Final assembly (assembly 4) (continued) Index number CCIN Part number Units Description 45D5201 Actuator assembly (lower left) 52C4 73Y4020 System VPD card 52D3 73Y3768 Controlled system VPD card (Tier 3) 2C17 73Y3847 System controller (FSP) 2C00 73Y3804 Clock card 2BAA 73Y3800 System backplane...
  • Page 281 Table 150. Final assembly (assembly 5) Index number CCIN Part number Units Description Lubricated node locking bracket assembly (rear) Finding parts, locations, and addresses...
  • Page 282 Table 150. Final assembly (assembly 5) (continued) Index number CCIN Part number Units Description 44P2994 As required Filler plate 44P2462 As required Filler plate 77G0599 Screw 74F1823 Nut clip 74Y0996 As required MDA-EZ assembly 15R8873 As required Blower assembly 46K3997 Light strip (rear) 45D2818 Connector cover...
  • Page 283 Table 151. Final assembly (assembly 6) (continued) Index number CCIN Part number Units Description 539C 73Y4114 As required Processor assembly, 6 core 41V0922 As required Book filler assembly 295B 45D9096 As required I/O hub card 2B74 73Y8782 As required GX++ 2-port 10 Gb FCoE CNA SR optical adapter 2B9B 73Y8776...
  • Page 284 Table 152. Cables (continued) CCIN Part number Description 036A 39J5820 3-meter SPCN cable 22R5219 6-meter SPCN cable 22R5221 15-meter SPCN cable 22R5222 30-meter SPCN cable 39J2561 10-meter HSL2 cable 42V2129 .6-meter 12X IB cable 42V2131 2.5-meter 12X IB cable 42R6160 8-meter 12X IB cable 32N1311 2-meter external cable...
  • Page 285 Table 153. Keyboards (continued) CCIN Part number Description 10N6968 Keyboard, French Canadian 32N1216 Keyboard, French Canadian 10N6973 Keyboard, French/German 10N6959 Keyboard, German 32N1208 Keyboard, German 10N6977 Keyboard, Greek 32N1226 Keyboard, Greek 10N6978 Keyboard, Hebrew 32N1227 Keyboard, Hebrew 10N6964 Keyboard, Hungarian 32N1213 Keyboard, Hungarian 10N6958...
  • Page 286 Door key 45D8467 Frame cover for 9119-FHA to 9119-FHB slim conversion (front) 45D4063 Frame cover for acoustic powered expansion rack cover set with IBM logos (rear) 45D4169 Frame cover for Slimline non-powered, bolt on expansion rack door without IBM logo (rear)
  • Page 287: 9125-F2C System Parts

    Table 154. Miscellaneous parts (continued) CCIN Part number Description 45D2624 SCM interposer cover 45D7265 SCM module 44V8405 SCM module handle 54G2882 Screw 45D2288 Tailgate 45D3627 Tailgate assembly 45D1986 Vertical bracket (left) 45D1987 Vertical bracket (right) 45D1677 Weight distribution plate kit 03N6070 Wrap plug 12R9314...
  • Page 288 Cover assembly Finding parts, locations, and addresses...
  • Page 289 Table 155. Cover assembly part numbers Index CCIN Part number Units per Description number assembly 41U7736 Rear door heat exchanger 74Y0502 Rear cover hinge (upper) Note: The rear, front cover hinges, latch brackets, and attaching screws are part of the front or rear door hardware-mounting kit field-replacement unit (FRU) and cannot be ordered separately.
  • Page 290 Table 155. Cover assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 74Y0502 Attaching screw for front cover hinge Note: The rear, front cover hinges, latch brackets, and attaching screws are part of the front or rear door hardware-mounting kit field-replacement unit (FRU) and cannot be ordered separately.
  • Page 291 Final assembly Table 156. Final assembly part numbers Index CCIN Part number Units per Description number assembly 41T8007 Bulk power and control enclosure (BPCE) 46K3779 Disk enclosure 45D9496 Disk enclosure rail (right) 45D9466 Disk enclosure rail (left) 2 - 12 Node assembly 45D9467 Rail for node assembly (right)
  • Page 292 Bulk power and control enclosure Table 157. BPR assembly part numbers Index CCIN Part number Units per Description number assembly 2C81 46K3802 Bulk power regulator (BPR) 2C82 41U7874 Bulk power control and communications hub (BPCH) 41U8369 Bulk power fan (BPF) 45D9113 Mounting bracket (front) 46K4159...
  • Page 293 Disk enclosure Table 158. Final assembly part numbers Index CCIN Part number Units per Description number assembly 46K3785 SAS expander card 46K3232 2 - 16 2 port disk enclosure (DE) SAS expander card 2A4A 46K3230 2 - 16 4 port DE SAS expander card Disk assembly 41U9323 Disk enclosure chassis...
  • Page 294 Table 158. Final assembly part numbers (continued) Index CCIN Part number Units per Description number assembly 74Y5497 1 - 4 200 GB small form factor SAS, solid-state drive (SSD) 6600 74Y9528 1 - 4 2.5 inch 400 GB SAS, SSD 2A4C 41U8213 SAS drive carrier...
  • Page 295 Table 159. CEC assembly part numbers Index CCIN Part number Units per Description number assembly 2C84 15R9510 Distributed converter and control assembly (DCCA) 31D7 45D9443 1 - 32 8 GB DIMM 31D0 45D9446 1 - 32 16 GB DIMM 42R4696 1 - 32 DIMM filler assembly 52C6...
  • Page 296 Fill and drain toolkit Table 160. Fill and drain toolkit parts Index number Part number Description 45D6928 Fill and drain tool (FDT) kit Finding parts, locations, and addresses...
  • Page 297 Table 160. Fill and drain toolkit parts (continued) Index number Part number Description 46K3778 FDT MDA card 45D2124 BTA water container (with water) 45D3063 BTA water container (without water) 45D6312 BTA spill kit 45D8560 FDT customer water plastic bottle 45D8561 FDT hose assembly.
  • Page 298: 5786, 5787, 7031-D24, And 7031-T24 System Parts

    For external cable FRU part number and description for your I/O enclosure, see the Site and hardware planning, order number SA76-0091. v For procedures on cabling your I/O enclosure, see Customer-Installable Features for the IBM p 570 (9117-MMA), order number SA76-0104. and go the topic "Connecting the 5786, 5787, 7031-D24 or 7031-T24 SCSI disk drive enclosure".
  • Page 299 v Throughout this topic, the abbreviation RoHS is used. RoHS refers to European Union Directive 2002/95/EC on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Site and hardware planning All part numbers are suitable for the 7031-T24, 7031-D24, 5786, and 5787 unless otherwise indicated.
  • Page 300 Table 163. I/O enclosure assembly (front view) Index CCIN Part number Units per Description number assembly 41U0299 Rack configured chassis assembly (includes chassis, disk drive backplane, VPD card). Removal and replacement procedures are sent with the FRU. 41U0301 Stand-alone configured chassis assembly (includes chassis, disk drive backplane, VPD card).
  • Page 301 300 GB Ultra320 10K rpm 80 pin SCSI disk 80P3157 drive/carrier 4326 39J3695 1-12 per side 3.5 inch 35 GB SCSI disk drive, 15K RPM (IBM i) 4327 39J3696 1-12 per side 3.5 inch 70 GB SCSI disk drive, 15K RPM (IBM i) 4328...
  • Page 302 Table 164. I/O enclosure assembly (back view) Index CCIN Part number Units per Description number assembly Chassis assembly (refer to table 2 for part number) Disk drive assemblies (refer to table 2 for part number) 506E 12R9042 SCSI repeater card assembly single 12R7477 506D 12R9040...
  • Page 303: 5796 And 7314-G30 System Parts

    5796 and 7314-G30 system parts Indexed drawings show system part numbers. Cover assemblies Table 165. Cover assembly part numbers Index CCIN Part number Units per Description number assembly 04N6587 Screw 80P5960 Front bezel 80P5955 Service label 39J5190 Rail assembly 39J5190 Rail assembly 80P6903 Air flow block...
  • Page 304 Table 166. Assembly Index CCIN Part number Units per Description number assembly 44V4294 300 W power supply 80P5880 Chassis assembly, includes power cables 42R4007 PCI adapter cassette, Gen 3 single wide (handle at bottom), long 42R4008 PCI adapter cassette, Gen 3 double wide (handle at bottom), long 10N7690 EMC shield assembly...
  • Page 305 Table 167. Final assembly part numbers Index CCIN Part number Units per Description number assembly 10N8782 GX card with hardware 10N7774 GX card with hardware 07P6949 Fabrication assembly 80P5940 Strain relief assembly (green) 03N5871 Strain relief assembly (olive) 520D 46K6826 SPCN card with hardware 03N5660 Hold down bracket...
  • Page 306: 5802 And 5877 System Parts

    Table 169. Miscellaneous parts (continued) CCIN Description Part number Cable configuration See Enclosures and expansion units. PCI filler bracket 39J0260 Wrap plug 87H3439 Wrap plug 87H3442 Wrap plug 87H3311 Wrap plug 73H2508 Wrap plug 93H5270 5802 and 5877 system parts Indexed drawings show system part numbers.
  • Page 307 Part number Units per Description number assembly 198B 00E6165* 0 - 18 69 GB 15K small form factor SAS disk drive (IBM 44V4429** 6600 42R8391** 0 - 18 73 GB 10K small form factor SAS disk drive (AIX and Linux) 198B...
  • Page 308 Back assembly Table 171. Back assembly part numbers Index CCIN Part number Units per Description number assembly 45D5321 PCI cage multicard assembly Comes with PCI cage multicard assembly and is not a separate FRU 45D5229 EMC card assembly 44V5743 EMC filler bracket 44V5739 Power cable assembly 45D5008...
  • Page 309: 5803 And 5873 System Parts

    387 GB small form factor solid-state SAS drive 59C0 00E8702* 0 - 26 775 GB small form factor solid-state SAS drive 198B 00E6165* 0 - 26 69 GB 15K small form factor SAS disk drive (IBM 44V4429** Finding parts, locations, and addresses...
  • Page 310 73 GB 15K small form factor SAS disk drive (AIX and Linux) 44V4426** 198C 00E6166* 0 - 26 139 GB 15K small form factor SAS disk drive (IBM i) 44V6844** 169C 42R8392** 0 - 26 146 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 311 2.5 meter IB cable 45D4787 3 meter IB cable 45D5271 8 meter IB cable 45D4788 4 meter SAS AE1 cable for IBM 7226 Multimedia Storage 46C2900 Enclosure Model 1U3 (7226-1U3) 3 meter SAS YE1 cable for 7226-1U3 46C2902 Table 177. Miscellaneous parts...
  • Page 312: 5886 System Parts

    Table 177. Miscellaneous parts (continued) CCIN Description Part number Cable configuration See Enclosures and expansion units. 5886 system parts Indexed drawings show system part numbers. Assembly Table 178. I/O backplane and cabling assembly part numbers Index number CCIN Part number Units Description 509A...
  • Page 313: Disk Drive And Solid-State Drive System Parts

    Table 179. Cables (continued) CCIN Part number Description 44V4147 1 meter SAS 4x EE cable 44V4148 3 meter SAS 4x EE cable 44V4149 6 meter SAS 4x EE cable 44V4151 3 meter SAS 2x cable 44V4152 6 meter SAS 2x cable 44V4157 1.5 meter SAS YO cable 44V4158...
  • Page 314 00LY323* 775 GB (528 block size) small form factor solid-state SAS drive 198B 00E6165* 69 GB 15K small form factor SAS disk drive (IBM i) 44V4429** 6600 42R8391** 73 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 315 00LY328* 775 GB (528 block size) small form factor solid-state SAS drive 19B0 00E6171* 139 GB 15K small form factor SAS disk drive (IBM i) 46K4804** 19B0 00E6173* 146 GB 15K small form factor SAS disk drive (AIX and Linux)
  • Page 316: 5887 System Parts

    00E8689* 600 GB 15K small form factor SAS disk drive (AIX and Linux) 19B4 74Y9285* 857 GB 10K small form factor SAS disk drive (IBM i) 19B4 74Y9286* 900 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 317 Final assembly Table 185. Final assembly part numbers Index number CCIN Part number Units Description 45W8836 Rail kit (left slide rail assembly) Attaching screw for the left slide rail assembly 45W8836 Rail kit (right slide rail assembly) Attaching screw for the right slide rail assembly Right bezel Left bezel...
  • Page 318 System assembly Table 186. System assembly part numbers Index number CCIN Part number Units Description 1 – 24 See Disk drive and solid-state drive system parts. Midplane assembly Attaching screw for the midplane assembly 50B0 45W9576 Midplane Attaching screw for the midplane 50B1 45W7653 Enclosure Services Manager (ESM)
  • Page 319: Disk Drive And Solid-State Drive System Parts

    00LY323* 775 GB (528 block size) small form factor solid-state SAS drive 198B 00E6165* 69 GB 15K small form factor SAS disk drive (IBM i) 44V4429** 6600 42R8391** 73 GB 10K small form factor SAS disk drive (AIX and Linux)
  • Page 320 00E9972* 300 GB 15K small form factor SAS disk drive (AIX and Linux) 19A3 74Y4897* 571 GB 10K small form factor SAS disk drive (IBM i) 59CE 00E8648* 571 GB 15K small form factor SAS disk drive (IBM i) 59E4...
  • Page 321 00LY328* 775 GB (528 block size) small form factor solid-state SAS drive 19B0 00E6171* 139 GB 15K small form factor SAS disk drive (IBM i) 46K4804** 19B0 00E6173* 146 GB 15K small form factor SAS disk drive (AIX and Linux)
  • Page 322: 5888 Or Edr1 Pcie Storage Enclosure System Parts

    5888 or EDR1 PCIe storage enclosure system parts Indexed drawings show system part numbers. System assembly Table 193. System assembly part numbers Index number CCIN Part number Units Description 46K3617 Top access cover assembly 45D4772 Attaching screw for top access cover assembly (upper) 45D4772 Attaching screw for top access cover assembly...
  • Page 323 Table 193. System assembly part numbers (continued) Index number CCIN Part number Units Description 73Y9667 Cable management bracket 46C6380 Attaching screw for cable management bracket 41T8061 Slide rail assembly (right) 12J5289 Attaching screw for slide rail assembly (right) 58BB 00V5433 6 - 30 1.8 inch 387 GB solid-state drive (SSD) 59BE...
  • Page 324 Finding parts, locations, and addresses...
  • Page 325: Notices

    All statements regarding the manufacturer's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only. The manufacturer's prices shown are the manufacturer's suggested retail prices, are current and are subject to change without notice. Dealer prices may vary. © Copyright IBM Corp. 2010, 2018...
  • Page 326: Trademarks

    IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at www.ibm.com/legal/copytrade.shtml.
  • Page 327 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 328 VCCI Statement - Japan The following is a summary of the VCCI Japanese statement in the box above: This is a Class A product based on the standard of the VCCI Council. If this equipment is used in a domestic environment, radio interference may occur, in which case, the user may be required to take corrective actions.
  • Page 329 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 330: Class B Notices

    Tel: 914-499-1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland GmbH Technical Regulations, Abteilung M372 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 7032 15 2941 email: lugi@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A.
  • Page 331 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment.
  • Page 332 Japanese Electronics and Information Technology Industries Association (JEITA) Confirmed Harmonics Guideline with Modifications (products greater than 20 A per phase) IBM Taiwan Contact Information Electromagnetic Interference (EMI) Statement - Korea Germany Compliance Statement Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse B EU-Richtlinie zur Elektromagnetischen Verträglichkeit...
  • Page 333: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 334 IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed. You may not download, export or re-export this information except in full compliance with all applicable laws and regulations, including all United States export laws and regulations.
  • Page 335 Notices...
  • Page 336 IBM® Printed in USA...

Table of Contents