Chapter 2. Prerequisites for the TS7620 Appliance Express,
ProtecTIER V3.3.2
|
|
|
Verify that the system is at the correct code level for the TS7620
Appliance Express, ProtecTIER V3.3.2
© Copyright IBM Corp. 2012, 2013
The following prerequisites must be met before you upgrade the software:
v The microcode level is 3.2 or greater.
v The system reports no existing errors that might prevent a successful upgrade.
v All ProtecTIER services are started.
Note: The SM2 base unit can increase capacity from 6 TB to 12 TB. If you need
capacity beyond 12 TB, purchase an SM2 expansion unit to increase capacity to 23
TB. You can increase capacity of an SM2 to 35 TB with two SM2 expansion units.
You must verify that the 3959 SM2 server is at the correct code level and size to
increase the storage capacity.
About this task
This task must be completed before you increase the storage capacity of the 3959
SM2 server.
Procedure
To verify that theProtecTIER level is at the correct code level on the server, and
that the system is the correct size for increasing the capacity, perform the following
steps:
1. Log in to the system with user name ptconfig and password ptconfig. The
ProtecTIER Service menu opens.
------------------------------------------------------------------------------
ProtecTIER Service Menu running on rassmx
------------------------------------------------------------------------------
1) ProtecTIER Configuration (...)
2) Manage ProtecTIER services (...)
3) Health Monitoring (...)
4) Problem Alerting (...)
5) Version Information (...)
6) Generate a service report
7) Generate a system view
8) Update ProtecTIER code
E) Exit
------------------------------------------------------------------------------
>>> Your choice?
2. Select the Version information option. Type the corresponding number and
press Enter. The Version information menu opens.