hit counter script
Download Print this page
Fujitsu UTY-XCBXZ2 Installation Manual
Fujitsu UTY-XCBXZ2 Installation Manual

Fujitsu UTY-XCBXZ2 Installation Manual

Air conditioner optional parts, external connect kit

Advertisement

Quick Links

AIR CONDITIONER
OPTIONAL PARTS
External connect kit
For authorized service personnel only.
Supplemental Manual
OPTIONAL KIT INSTALLATION (OPTION)
This air conditioner can be connected with the following optional kits.
• Wired remote controller
• Simple remote controller
• External connect kit
BEFORE INSTALL WIRED REMOTE CONTROLLER
• When you use wired remote controller, some functions may not be used.
• Before installing, be sure to disconnect all power supply.
• Don't touch the heat exchanger.
• During installing or removing operation, be sure not to have wire caught by parts or
draw it hard. Or it may result troubles to the air-conditioner.
• Avoid place in direct sunlight.
• Select place that will not be affected by the heat from a stove, etc
• Before setting up the optional kit, please con¿ rm whether air-conditioner can receive
the signal.
• Do not connect the wired remote controller to the terminal for power supply.
• When connecting the wired remote controller with the indoor unit, use the connecting
cable (supplied with wired remote controller or simple remote controller).
• Recommended cable length of wired remote controller is 32 ft. (10 m). Make sure to
do insulate of connecting part when extended the cable.
Do not connect power supply with the terminal.
INDOOR UNIT
TERMINAL
INSTALLATION WORK
Remote controller cord modi¿ cation
(1) Use a tool to cut off the terminal on the end of the remote controller cord, and then
remove the insulation from the cut end of the cord.
(2) Connect the remote controller cord and connecting cord.
(supplied with wired remote controller)
Important: Be sure to insulate the connection between the cords.
Remote
controller cord
Remote
controller cord
Installing wired remote controller terminal /
external connect kit terminal (sold separately)
(1) Remove the screw on the control box as shown on the top right of the figure below.
(2) Release both bottom clasps at the sides in the direction of the arrow as circled in
the bottom left of the figure below. Pull and remove the cover.
En-1
CAUTION
PCB
Connecting cord
White
Red
Black
White
Red
Insulated
connection
Black
Cover
(2)
(3) Connect the wired remote controller terminal / external connect kit terminal (sold
separately) to the specified terminal on the board as shown below. Please connect
to the connector with necessary function according to the actual usage.
(4) After connecting each terminal, thread the cables through the notch as circled on
the bottom right of the figure below.
(3) Wired remote controller
connector
: CNC01(White) *
(3) Control input (Operation/
Stop or Forced stop) con-
nector
: CNA01(White) *
* : Symbol indicating the location printed on the board
(5) Install the control box cover as shown below.
(Align the cover with the upper and lower right corners as indicated by the triangular
symbols on the figure.
Insert the clasps on the cover into both sides at the bottom of the two dotted
circles.)
• When installing the control box cover, make sure that the cables are not caught as
shown in the detail view.
(6) Install one screw.
(7) Screw the earth wire of wired remote controller as shown in the figure.
(AUSTRALIA model only).
Cover
(6)
(5)
Installing communication box
Removing intake grille
(1) Remove the screws (x4). (Use the same screws when installing.)
(2) Pull the control box cover towards you and remove.
(1)
(1)
(1)
(1)
(3) Remove the connectors (x4).
• Remove and pull off the lock at the side of the connector insertion part.
(1)
(3) Error Status output
connector
: CNB02(Black) *
(3) Operation status
output connector
: CNB01(White) *
(4)
Detail view
(5)
(7)
(2)

Advertisement

loading

Summary of Contents for Fujitsu UTY-XCBXZ2

  • Page 1 AIR CONDITIONER OPTIONAL PARTS Cover External connect kit For authorized service personnel only. Supplemental Manual (3) Connect the wired remote controller terminal / external connect kit terminal (sold separately) to the specified terminal on the board as shown below. Please connect to the connector with necessary function according to the actual usage.
  • Page 2 Installing communication box CAUTION (1) Install the communication box on the main unit and secure it with the provided screw at the location shown below. • Be careful not to damage the parts on the board. View A (Detail view) Otherwise, it will cause malfunction.
  • Page 3 (7) Tighten with screws to prevent the cover of the control box from falling off. (When installing, reuse the screws that was removed in Removing control box.) (8) Paste protect seals (2 locations) to prevent the wires from sticking out. (3) Fasten the earth wires of the heat exchanger together as shown in the left figure above.