hit counter script
Download Print this page

C.R. Laurence C9ASA Installation Instructions

Counter-top communicators

Advertisement

Quick Links

C.R. LAURENCE CO., INC.
INSTALLATION INSTRUCTIONS FOR COUNTER-TOP COMMUNICATORS
B
EXTERIOR UNIT
X
D
G
F
E
1. Unpack the Interior Unit ( ) and Exterior Unit (B). Check to be sure all parts shown on this diagram are included.
2. Use the supplied Security Torx Bit (C) to remove the screws in the lower back corners (D) of both the Interior and
Exterior Units.
3. Remove the Mounting Plates (E) from the underside of the Interior and Exterior Units.
4. Position the Mounting Plates on the interior and exterior side of the glass or other partition. The Mounting Plates
are typically installed flush against the partition. Depending on the condition of the partition, the optional rubber
bumpers (F) can be applied to the back of the Mounting Plates if needed.
5. Using a pen or a center punch, mark the counter for the locations of the Mounting Screws (G) and the access holes for
the 2-wire Power Cable (H) and the 5-wire Communication Cable (I). The interior side needs access for both cables.
The exterior side only needs access for the Communication Cable (I).
6. Move the Mounting Plates and pre-drill the counter for the supplied screws. If the counter is made of a solid material
such as granite, drill for installing the optional Screw Anchors (J). Also, drill access holes for the Power Cable (H) and
the Communication Cable (I).
One end of the Communication Cable (I) has the five inner wires exposed. Keep 9" - 12" (227mm -305mm) of this end on
7.
the interior unit side, and feed the Communication Cable through its access hole. On the exterior unit side, cut off excess
cable so that about 9" - 12" (227mm -305mm) projects from the hole. Strip the outer gray insulation sheath back to
expose approximately 1-1/2" (38mm) of the five inner wires. Peel the shielding foil away as well. Do not cut the
silver-colored shielding wire. The remaining four wires each have a different color insulation sheath. Strip each sheath
back to expose approximately 1/8" – 3/16" (3mm - 5mm) of bare wire.
crlaurence.com • Phone Toll Free (800) 421-6144 • Fax Toll Free (800) 458-7496
FOR MODELS: C9ASA C9ABL
F
J
H
SPEAKER
D
T
M
O
K
L
I
N
INTERIOR UNIT
S
Q
R
P
G
F
E
J
C
D
F
AVD3992 10/13

Advertisement

loading

Summary of Contents for C.R. Laurence C9ASA

  • Page 1 C.R. LAURENCE CO., INC. FOR MODELS: C9ASA C9ABL INSTALLATION INSTRUCTIONS FOR COUNTER-TOP COMMUNICATORS INTERIOR UNIT SPEAKER EXTERIOR UNIT 1. Unpack the Interior Unit ( ) and Exterior Unit (B). Check to be sure all parts shown on this diagram are included.
  • Page 2 8. One end of the Power Cable has the two inner wires exposed. Keep 9" - 12" (227mm -305mm) of this end on the inner unit side and feed the Power Cable through its access hole toward where the unit will be plugged into a wall outlet. Cut off an appropriate amount of excess Power Cable, considering the length of the cable attached to the Transformer (L).

This manual is also suitable for:

C9abl