Hydraulic Fluid Leak Detector Kit
Greensmaster
Model No. 04730
This product contains a chemical or chemicals known to the State of California
Installation
Loose Parts
Use the chart below to verify that all parts have been shipped.
Procedure
1
2
3
© 2017—The Toro® Company
8111 Lyndale Avenue South
Bloomington, MN 55420
®
3300/3400 Series TriFlex
Proposition 65 Warning
to cause cancer, birth defects, or reproductive harm.
Description
No parts required
Wire harness
Cable tie
Indicator light
Audio alarm
Spout
Leak detector tank
Oil level sensor
O-ring
Valve hose
Tank valve hose
Hex-head bolt (1/4 x 2 inches)
Shield bracket
Hose clamp
Solenoid valve assembly
Straight fitting
90° hydraulic fitting
90° hydraulic fitting (beaded)
Delay timer (diesel model only)
Screw (5/8 inch)
Locknut
Oil level cover (diesel model only)
Oil level cover (gasoline model only)
Overflow hose
Worm-drive clamp
Register at www.Toro.com.
WARNING
CALIFORNIA
Qty.
1
8
1
1
1
1
1
1
1
1
2
1
4
1
1
2
1
1
1
1
1
1
1
2
Form No. 3419-997 Rev A
®
Traction Unit
Installation Instructions
Use
Prepare the machine for installation.
Prepare to install the leak detector tank.
Install the leak detector tank.
Original Instructions (EN)
All Rights Reserved *3419-997* A
Printed in the USA.

Advertisement

loading

Summary of Contents for Toro 04730

  • Page 1 Hydraulic Fluid Leak Detector Kit Greensmaster ® 3300/3400 Series TriFlex ® Traction Unit Model No. 04730 Installation Instructions WARNING CALIFORNIA Proposition 65 Warning This product contains a chemical or chemicals known to the State of California to cause cancer, birth defects, or reproductive harm.
  • Page 2: Preparing The Machine

    Procedure Description Qty. Plug Complete the leak detector tank installation. Dipstick Ensure that the leak detector is – No parts required operating correctly. the oil level sensor and solenoid valve leads are near the main hydraulic tank (diesel model only). Refer to Figure 1 for an overview of the...
  • Page 3 g236699 Figure 4 1. Plug 2. Spout Insert the spout into the rubber grommet (Figure g016172 Figure 2 1. Console arm frame 3. Threaded ring 2. Audio alarm Connect the audio alarm to the main wire Installing the Leak Detector harness (gasoline model only) or to the kit wire harness (diesel model only).
  • Page 4 There are 2 different oil-level covers in the kit, 1 for gasoline machines and the other for diesel machines. The cover for the diesel machine is longer than the cover for the gasoline machine and may have a “D” etched in it. Use the screw (5/8 inch) and locknut to install the delay timer on the oil-level cover (diesel model only);...
  • Page 5: Completing The Installation

    g016176 g016177 Figure 8 Figure 9 1. Straight hydraulic fitting 2. Leak detector tank 1. Remove plug from main 2. Indicator arrow on nut (2) hydraulic tank here. Secure 1 end of the valve hose to the 90° Slide the O-ring onto the hydraulic-oil-level hydraulic fitting connected to the back of the sensor and install the sensor into the hydraulic solenoid valve with a worm-drive clamp.
  • Page 6 Fill the leak detector tank with hydraulic fluid until the fluid level is at the middle of the sight window. • If your leak detector tank does not have a sight window: Fill the leak detector tank with hydraulic fluid until the fluid level is at the middle of the fill marks on the dipstick;...
  • Page 7 Checking the Leak Detector No Parts Required Understanding the Leak Detector System The leak detector system is designed to assist in early detection of hydraulic-fluid-system leaks. If the fluid g229109 Figure 14 level in the main hydraulic reservoir is lowered by 118 to 177 ml (4 to 6 fl oz), the float switch in the tank Normal Operation (fluid warm) will close.
  • Page 8 Checking the the machine to stand for 1 to 2 minutes to allow the fluid levels to stabilize. Then start the machine and Leak-Detector-System Operation operate it in a non-sensitive area to confirm that no Move the ignition switch to the O position.