KV-AR292N90
RM-W150
e. OTHER FUNCTION VIA REMOTE COMMANDER
7, -
All the data becomes the values in memory.
8, -
All user control goes to the standard state.
Display, -
Service data initialization (Be sure not to use usually.)
2, 5
Select Device or Category (Up, Down)
3-2. ADJUSTMENT METHOD
Item Number 000 HPOS
This explanation uses H POSITION as an example.
1. Select "000 HPOS" with the
2. Raise/lower the data with the
3. Select the optimum state. (The standard is IF for PAL reception.)
4. Write with the [MUTING] button. (The display changes to WRITE.)
5. Execute the writing with the
SERVICE.)
Example on screen display :-
Use the same method for all Items. Use
[MUTING], then execute the write with
Note : 1. In [WRITE], the data for all items are written into memory together.
2. For adjustment items that have different standard data between 50Hz or 60Hz, be sure to use the respective
input signal after adjustment.
and
buttons, or
and
1
4
2
and
buttons.
3
6
button. (The WRITE display will be changed to red color while excuting, and back to
-
GREEN
GEOM 00 HPOS 039 SERVICE 50 VIDEO 1
Adjusted with 3 and 6 buttons
GREEN
GEOM 00 HPOS 039 WRITE 50 VIDEO 1
Write with [MUTING]
RED
GEOM 00 HPOS 039 WRITE 50 VIDEO 1
Write executed with -
and
to select the adjustment item, use
1
4
.
-
– 14 –
.
5
The WRITE display
then returns to green
SERVICE.
3
and
to adjust, write with
6