Quick-view parameter list
The following values are factory settings:
Value/setting
Parameter-
number
Man.
RMC
50
00.
70
01.
85
02.
70
03.
50
04.
02
05.
15
06.
60
07.
5,0
08.
03
09.
F0
10.
F0
11.
30
12.
09
13.
03
14.
00
*
Payment machines:
487 18 39 01 - 300/500/750 - GB
Parameter programming
Man.
*Coin
*CP
Time
10
11/51
12
30
31/71
32
85
85
85
70
70
70
50
50
50
02
02
02
15
15
15
60
60
60
5,0
5,0
5,0
03
03
03
--
--*
--*
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Parameters 09-14 cannot be set.
Will run without payment (bypassing the control panel)
if the machine code is set to 43
Machine types.
W/o rev.
Standard and condensate versions.
W/ rev.
Programme with high temperature.
Programme with medium temperature.
Low temperature
Temperature hysteresis
Time interval,
running time per pulse (per coin or push)
Max. time or time interval for "coin 2"
Running time between reversals
Cooling time
Moisture level: P1 (extra dry)
Moisture level: P2 (ready to put away)
Moisture level: P3 (ironing dry)
Extra drying time: P1
Extra drying time: P2
Extra drying time: P3