hit counter script
Hide thumbs Also See for DVP-NS72HP:
Table of Contents

Advertisement

DVP-NS72HP/NS77H/NS77HP/NS78H/NS78HP
(6)
Error code list
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mecha move error (5 Changer)
26: Mecha move stack error
30: DC Motor adjustment error
31: DPD offset adjustment error
32: TE Balance adjustment error
33. TE Sensor adjustment error
34. TE loop gain adjustment error
35. FE loop gain adjustment error
36. Bad jitter after adjustment
40. Focus NG
42. Focus Layer Jump NG
50. Open kick spindle error
51: Spindle stop error
60: Focus on error
61: Seek fail error
62: read Qdata/ID error
70: Lead In Data Read Fail
71: TOC read time out (CD)
80: Can't Buffering
81: Unknown media type
(7)
Error code parameters
Example of Error code
1. 01 05 04 04
00 00 00 00
r
This is the detailed contents of error information
(For design used only)
(8)
Laser hours at error happend.
Example of Error code
1. 01 05 04 04
00 00 00 00
This is Laser hours when an error happened.
(9)
How to Clear laser hours
Press [DISPLAY], [CLEAR] keys in this order.
Both CD and DVD data are cleared.
Emg. History Check
Laser Hours
CD
DVD
1. 01 05 04 04
00 00 00 00
2. 02 02 01 01
00 00 00 00
[Next] Next Page [Prev] Prev Page
- Return to Top Menu
00 92 46 00
00 00 23 45
00 92 46 00
00 00 23 45
r
0 h
0min
0 h
0min
00 92 46 00
00 00 23 45
00 A9 4B 00
00 00 23 45
(10) How to Clearing Emergency code
Press [TOPMENU], [CLEAR] keys in this order.
All emergency code are cleared.
Emg. History Check
Laser Hours
CD
DVD
1. 00 00 00 00
00 00 00 00
2. 00 00 00 00
00 00 00 00
[Next] Next Page [Prev] Prev Page
Return to Top Menu
-
(11) Press - key, return to TOP MENU.

6-3. INITIALIZING SETUP DATA

How to initializing setup data.
(1) In standby mode, press [TOP MENU], [CLEAR], [POWER] to
enter Remocon Diagnosis Mode.
(2) Select "3. Emergency History".
Emg. History Check
Laser Hours
CD
DVD
1. 01 05 04 04
00 00 00 00
2. 02 02 01 01
00 00 00 00
[Next] Next Page [Prev] Prev Page
- Return to Top Menu
(3) Initializing setup data
Press [MENU], [CLEAR] keys in this order.
The data have been initialized when "Initialize setup data..."
mesage is displayed.
Emg. History Check
Laser Hours
CD
DVD
Initialize setup data ...
[Next] Next Page [Prev] Prev Page
- Return to Top Menu
6-2
999h
59min
999h
59min
00 00 00 00
00 00 00 00
00 00 00 00
00 00 00 00
999h
59min
999h
59min
00 92 46 00
00 00 23 45
00 A9 4B 00
00 00 23 45
999h
59min
999h
59min

Advertisement

Table of Contents
loading

Table of Contents