4.5
Pin mapping of modular connector
4.6
Power supply terminal clamps
Security Products
The 6-pole Modularjack on the backside of the device is wired parallel to the 9-pole
Sub-D-Connector and designated for connection on the Videomatrix-System
SIMATRIX NEO. Only one jack should be connected at a time.
Pin
TTY
1
GND
2
TTY-OUT-
3
TTY-OUT+
4
TTY-IN-
5
TTY-IN+
6
12 V DC
* RS232 must not be connected on a cable longer than 5 meters
1
Fig. 4
Terminal clamps
1
Terminal clamps
Connecting an external power supply is not needed when videomatrix can supply
the HMI device (see mapping of TTY inferface) or a PoE LAN connection is used.
Videomatrix VKS648 can supply power for two SUT50, SIMATRIX NEO not more
than four devices. VM1000-CPU is cabable to provide power supply for all 16
connectable devices.
Do not exceed maximum load of videomatrix by powering more SUT50 than described above!
In all other cases the attached external wall power supply can be used, which is
connected to the 9-pole Sub-D connector. If the Sub-D connector is already in use
the power supply can be connected to the internal terminal clamps. (see Fig. 4)
RS485
RS232*
GND
GND
TxD-
RxD
TxD+
TxD
RxD-
n.c.
RxD+
GND
12 V DC
12 V DC
Setting-up for operation
11
UM_SUT50_EN.doc
06.2014