Setting-up for operation
4
Setting-up for operation
4.1
Power supply
4.2
Environmental Conditions
8
Security Products
The wall power supply is only provided for operation in TN networks (according
–
to VDE 0100, part 300 or EN 60950-1). For safe operation the device must be
protected by an external overcurrent protection rated no more than 16 A.
The supplied wall power supply can be connected to electrical supplies with
–
voltages of 100 to 240 VAC (+10% / -15%) at 50/60 Hz
Only use wall plug adapters or wall power supplies complying with local
–
permissions or regulations
Comply with the environmental conditions specified by the manufacturer
–
– operating temperature: + 5C to 45C
– relative humidity: 30 to 85 %, non-condensing
Protect the device from moisture and fluids
–
Do not expose the device to direct thermal radiation (e.g. heating devices)
–
Do not operate the device in very dusty environments
–
Do not operate the device in the neighbourhood of a strong source of
–
electromagnetic waves
Do not expose the device to mechanical shocks
–