Transponder
7.6 SIMATIC RTLS PCB OEM AC
Unauthorized opening of and improper repairs to the device may cause substantial risks to the
user. As soon as the device was opened without permission, warranty and liability of the
Siemens AG are rendered null and void.
Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
7.6.3
Technical specifications
Table 7-15
Technical specifications of the transponder RTLS PCB OEM AC
Product name
PULSE radio frequencies (localization)
Wireless method
Transmission speed
Operating frequency rated value
Transmit power
Range
Accuracy of the localization
Antennas
PHASE radio frequencies (data transfer and optional locali‐
zation)
Wireless method
Transmission speed
Operating frequency rated value
Transmit power
Range
Accuracy of the localization
Antennas
Bandwidth
Supply voltage, power consumption
Supply voltage
Energy intake
Permitted ambient conditions
Ambient temperature
Design, dimensions, weights and connectors
170
SIMATIC RTLS PCB OEM AC
IEEE 802.15.4-2011 UWB
6.8 Mbps
3100 MHz ... 4800 MHz
6000 MHz ... 7000 MHz
0.037 mW (-41.3 dBm/MHz)
Max. 30 m
0.2 m
UWB antenna integrated
IEEE 802.15.4
1 Mbps
2.40 ... 2.48 GHz ISM band
Max. 4 dBm (can be set)
Max. 50 m
1 m
2.4 GHz antenna integrated
2 MHz; data transmission on 802.15.4; channels can be set
3.3 V DC (±100 mV)
Max. 0.5 A
0 to +50 °C
System Manual, 04/2019, C79000-G8976-C577-01
6GT2700-8DF00-0AX1