2.3
Cable Connections and Pin Assignments
The LCD-monitor has been tested and set-up in the factory. Before use, the power supply
and the input signals should be connected to the provided sockets. Connections to the
monitor should adhere to EMC regulations.
A high-quality 75-ohm coaxial cable must be used for the VGA-signals. Low quality cables
can result in interference and shadowing on the display.
2.3.1
DVI Interface
The DVI interface is a 29-pin DVI-connector.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
LCD-Monitor SCD 1597-I
Signal
TMDS-Data 2 -
TMDS-Data 2 +
TMDS-Data Shield 2 (GND)
-
-
DDC-CLK
DDC-DATA
Analogue V-Sync.
TMDS-Data 1 -
TMDS-Data 1 +
TMDS-Data Shield 1 (GND)
-
-
+5 V Power (In)
GND
Hot Plug Detect
TMDS-Data 0 -
TMDS-Data 0 +
TMDS-Data Shield 0 (GND)
-
-
TMDS-CLK Shield (GND)
TMDS-CLK +
TMDS-CLK -
Page 31 / 41