Page 1
TLP-MT1 — S U M M A R Y — TLP-MT1 is based on TLP450E and TLP450U. This service manual covers only different portions from service manual (File No. 333-9904) for TLP450E and TLP450U. PRINTED IN JAPAN, Dec., 1999 CS...
Page 2
The following parts list covers only the different parts from the base models. For the other parts, please refer to the service manual (File No. 330-9904) of the base models. Location Part No. Description A400 23064069 Case A302 23550982 Rating Label A300 23550983 Front Tag...
Page 3
FILE NO. 330-9904 SERVICE MANUAL 3LCD DATA PROJECTOR TLP450E, TLP451E TLP650E, TLP651E TLP450U, TLP451U TLP650U, TLP651U TLP451, TLP651 PRINTED IN JAPAN, Oct., 1999...
CONTENTS SAFETY PRECAUTIONS .............. I IMPORTANT PRECAUTIONS ............ I IMPORTANT SAFETY INSTRUCTIONS ......II SECTION 1 PART REPLACEMENT AND ADJUSTMENT PROCEDURES 3-11. Input PC Board ............... 1-6 1 . LOCATION OF MAIN PARTS ......... 1 - 1 2 . LOCATION OF PC BOARDS ........... 1 - 1 3-12.
SECTION 1 PART REPLACEMENT AND ADJUSTMENT PROCEDURES 1. LOCATION OF MAIN PARTS TLP451/651 E200 Optical Engine PC300 Camera Unit Assembly B180 Lamp House P800 Power Unit Z101 Fan SC01 Arm Position Detection Switch P100 Thermal Lead Switch LCD Block Projection Lens Filter Fig.
CAUTIONS BEFORE STARTING SERVICING Electronic parts are susceptible to static electricity and may easily damaged, so do not forget to take a proper grounding treatment as required. Many screws are used inside the unit. To prevent missing, dropping, etc. of the screws, always use a magnetized screwdriver in servicing.
3-3. Front Cover and Top Cover Screws (4) Main PC board (1) Connectors (2) 1. Remove two screws (1) and remove the front cover (2) by sliding the portion A pushed with a thin bar in the arrow B direction. 2.
3-6. Handle and Fan Assembly 3-7. Power Supply Unit 1. Pull out the handle (1) upward. 1. Remove two screws (1) and then remove the shield plate (2) and the socket (3). (Do not lose the shield 2. Remove two screws (2) and fan assembly (3). plate (2).) 3.
Temperature 3-8. Filter Assembly Screw (4) sensor switch (5) 1. Remove the filter cover (1) from the suction fan Screw (1) holder (2). 2. Remove the filters (3) and (4) from the filter cover (1). Lamp house (3) (When replacing and/or cleaning the filter, note the arrangement of the filters.
Page 10
3-11. Input PC Board 3-13. Mirror Box 1. Remove five screws (1). 1. Remove three screws (1) and then remove the mirror box (2). 2. Remove the input PC board (2) by turning the arrow direction. Screws (1) Screws (1) Input PC board (2) Mirror box (2) Fig.
Page 11
3-14. LCD Block and LCD Panel 3. Mount a holder support for the service holder at the location of the panel holder removed. (Use screws 1. Remove three screws (1) and remove the LCD block (2). removed in step 2.) (Refer to Fig. 1-3-16 for the 2.
Page 12
< Holder fixing > 2. Tighten the S adjusting screws with a wrench for servicing and fix the Z rotation plate. (Refer to Fig. 1- 1. Apply screw lock to the S adjusting screws. 3-17.) If the focus adjusted is upset when fixing, 2.
Page 13
3-15. CAM SW PC Board 3-16. Arm Assembly (Only for TLP451/651) (Only for TLP451/651) 1. Remove one screw (1) and remove the cover (2). 1. Remove three screws (1) and remove the arm assem- bly (2). 2. Remove four connectors (4) connected to the CAM SW PC board (3).
Page 14
3-17. Switch (Only for TLP451/651) 3-19. Lamp PC Board (TLP451/651) 1. Remove two screws (1) and remove the base plate (2). 1. Remove the lamp cover (1). 2. Remove one screw (3) and remove the switch (4). 2. Pull out the lamp PC board (2) in the arrow direction. 3.
Page 15
(2) Adjustment software usage 4. ELECTRICAL ADJUSTMENT The electrical adjustment is carried out by using the < Test Equipments and Test Jigs > adjustment software. For the adjustment command items • Oscilloscope in the adjustment procedures, set the command by •...
Page 16
4-1. LCD Drive Adjustment • Save the data in each step. Table 1-4-1 ( ) : confirmation only. Test Adjust Adjust Items Input Signal Equip- Test Point Adjust Value Note mode ment 1. Input level check 1-1. Input level 16-stairstep Oscillo- TP701 (R) •...
Page 17
Table 1-4-2 Test Adjust Adjust Items Input Signal Equip- Test Point Adjust Value Note mode ment 5. Gamma correction at 10th stairstep video input 5-1. Video bias 10-stairstep Oscillo- TP402 (R) • Adjust the 10th adjustment waveform scope TP502 (G) stairstep wave- TP602 (B) form for following...
Page 18
Table 1-4-3 Test Adjust Adjust Items Input Signal Equip- Test Point Adjust Value Note mode ment 7. White balance All white 50% Color Shown • Shown below. adjustment signal lumi- below nance 10-stairstep meter video signal (BM-5) 16-stairstep RGB signal 1.
Page 19
Special All data read (X command) Timer Initialize Read Option TOSHIBA logo Keystone format (Deg) 0 (High-temp) Send CMD Receive CMD Fig. 4 4. Place TLP450/451/650/651 to be adjusted horizontally on a flat table and click “0” of keystone format (Deg) on the menu and store the data at the horizontal position.
Page 20
5. LED DISPLAY X: Lighting off, Color: Contents shown by lighting in the color, (Color): Contents shown by blinking in the color Table 1-5-1 Normal operation Status Power Lamp Temp Contents Remarks Additional notice Normal Orange Standby status At normal power off Normal Green Power on...
SECTION 2 SERVICING DIAGRAMS 1. PART CONFIGURATION AND THEIR SYMBOLS 1-1. Replacing Subminiature "CHIP" Parts 1-1-4. Removal (Transistors, Diodes, etc.): 1. Melt the solder of one lead. 1-1-1. Required Tools: 1. Fine tipped, well insulated soldering “pencil”, about TWEEZERS 30 Watts. 2.
1-2. Precautions for Part Replacement • In the schematic diagram, parts marked (ex. • Using the parts other than those specified shall F801) are critical part to meet the safety regulations, violate the regulations, and may cause troubles such so always use the parts bearing specified part codes as operation failures, fire etc.
The panel driving timing signal is generated in the 2. EACH SIGNAL FLOW timing generator IC (Q203) with a clock signal and HD/ VD signal supplied from the digital circuit. The Up/Down 2-1. Operation at RGB Signal Input and Left/Right display inversion on the LCD panel (for The RGB signal is entered from PB001 on the RGB PC ceiling mounting and rear projection status) is carried out board and sent to the main PC board after passing...
2-3. Operation at Y/Pb/Pr Signal and 2-5. Camera Overlay Signal The camera overlay signal usually enters the A/D HDTV Signal Input converter for Y/Cb/Cr signal (Y/Pb/Pr) through an Y/Cb/Cr signal (DVD player output) or HDTV signal exclusive connector in the same way as that of camera enters from PB001 and reaches the A/D converter input.
3-2. Input Block Diagram QA01 S-Video To main board QA02 QA03 Video Video QA06 Audio QA10 QA09 Vol. & Tone Power Amp Selector Audio (PC) Speaker from RGB board QA14 QA15 To main board QA16 (Emitter Follower) Camera Fig. 2-3-2...
3-3. Main Block Diagram 3-3. Digital Block Diagram QD407 QD406 PLL for Memory for QD001 Overlay Overlay 24.567 MHz Tilt PLL circuit for Sensor Q407 overlay Timing Signal Video QD200 Level Shift S - Video VIDEO Video Data (8bit) QD401 QD405 DECODER Timing Signal for LCD Panel...
6-4. RGB PC Board Fig. 2-6-7 U0021 RGB PC Board (Top Side) Fig. 2-6-8 U0021 RGB PC Board (Bottom Side) 6-5. LED PC Board 6-6. Sub Digital PC Board Fig. 2-6-9 U0032 LED PC Board (Top Side) Fig. 2-6-11 U007 Sub Digital PC Board (Top Side) Fig.
SECTION 3 PARTS LIST SAFETY PRECAUTION The parts identified by mark are critical for safety. Replace only with part number specified. The mounting position of replacement is to be identical with originals. The substitute replacement parts which do not have the same safety characteristics as specified in the parts list may create shock, fire or other hazards.