Mitsubishi Electric MXZ-6F122VF Installation Manual

Mitsubishi Electric MXZ-6F122VF Installation Manual

Split-type air-conditioner

Advertisement

Quick Links

Split-type Air-Conditioner
MXZ-6F122VF
English is original.
Übersetzung des
Originals
Traduction du texte
d'origine
Vertaling van het
origineel
Traducción del
original
Traduzione
dell'originale
Μετάφραση του
αρχικού
Tradução do
original
Oversættelse af
den originale tekst
Översättning från
originalet
Orijinalin çevirisi
Оригиналът е текстът
на английски език
Językiem oryginału
jest język angielski
Originalspråket er
engelsk
Installation Manual
• This manual only describes the installation of outdoor unit.
When installing the indoor unit, refer to the installation manual of indoor unit.
Installationsanleitung
• Diese Installationsanleitung gilt nur für die Installation des Außengerätes.
Zur Installation des Innengeräts siehe die Installationsanleitung für Innengeräte.
Notice d'installation
• Cette notice ne décrit que l'installation de l'appareil extérieur.
Lors de l'installation de l'appareil intérieur, consultez la notice d'installation de
cet appareil.
Installatiehandleiding
• Deze handleiding beschrijft alleen de installatie van de buitenunit.
Raadpleeg de installatiehandleiding van de binnenunit wanneer u deze
installeert.
Manual de instalación
• En este manual sólo se describe la instalación de la unidad exterior.
Para instalar la unidad interior, consulte el manual de instalación de dicha
unidad.
Manuale per l'installazione
• Questo manuale descrive solo l'installazione dell'unità esterna.
Per l'installazione dell'unità interna, fare riferimento al relativo manuale di
installazione.
Εγχειρίδιο εγκατάστασης
• Στο παρόν εγχειρίδιο περιγράφεται μόνο η εγκατάσταση της μονάδας εξωτερικού χώρου.
Για την εγκατάσταση της μονάδας εσωτερικού χώρου, ανατρέξτε στο εγχειρίδιο
εγκατάστασης της μονάδας εσωτερικού χώρου.
Manual de Instalação
• Este manual descreve apenas a instalação da unidade exterior.
Quando proceder à instalação da unidade interior, consulte o manual de instalação
da unidade interior.
Installationshåndbog
• Denne håndbog beskriver kun, hvordan udendørsenheden installeres.
Vedrørende installation af indendørsenheden henvises til installationshåndbogen
for indendørsenheden.
Installationsanvisning
• Denna installationsanvisning beskriver endast installation av utomhusenheten.
Se den separata installationsanvisningen för inomhusenheten.
Kurulum Kılavuzu
• Bu kılavuzda yalnızca dış ünitenin kurulumu açıklanmaktadır.
İç ünite kurulum işlemini yaparken iç ünite kurulum kılavuzuna bakın.
Ръководство за монтаж
• Това ръководство описва само монтажа на външното тяло.
При монтиране на вътрешното тяло вижте ръководството за монтаж на
вътрешното тяло.
Instrukcja montażu
• Niniejsza instrukcja zawiera tylko opis instalacji jednostki zewnętrznej.
W przypadku instalowania jednostki wewnętrznej należy odnieść się do instrukcji
montażu jednostki wewnętrznej.
Installasjonshåndbok
• Denne håndboken beskriver installasjonen av den utvendige enheten.
Når den innvendige enheten skal installeres, se installasjonshåndboken til den
innvendige enheten.
For INSTALLER
Für INSTALLATEUR
Destinée à l'INSTALLATEUR
Voor de INSTALLATEUR
Para el INSTALADOR
Per il TECNICO INSTALLATORE
Για τον ΤΕΧΝΙΚΟ
Para o INSTALADOR
Til INSTALLATØREN
För INSTALLATÖREN
TESİSATÇI İÇİN
За ИНСТАЛАТОРА
DLA INSTALATORA
For INSTALLATØR
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
Português
Dansk
Svenska
Türkçe
Български
Polski
Norsk

Advertisement

loading

Summary of Contents for Mitsubishi Electric MXZ-6F122VF

  • Page 1 Split-type Air-Conditioner MXZ-6F122VF For INSTALLER Installation Manual English is original. English • This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of indoor unit. Für INSTALLATEUR Installationsanleitung Übersetzung des Deutsch Originals •...
  • Page 2 Manual Download http://www.mitsubishielectric.com/ldg/ibim/ EN Go to the above website to download manuals, select model name, then choose language. DE Besuchen Sie die oben stehende Website, um Anleitungen herunterzuladen, wählen Sie den Modellnamen und dann die Sprache aus. FR Rendez-vous sur le site Web ci-dessus pour télécharger les manuels, sélectionnez le nom de modèle puis choisissez la langue. NL Ga naar de bovenstaande website om handleidingen te downloaden, de modelnaam te selecteren en vervolgens de taal te kiezen.
  • Page 3: Table Of Contents

    Required Tools for Installation CONTENTS Phillips screwdriver Flare tool for R32, R410A Level Gauge manifold for R32, R410A 1. BEFORE INSTALLATION ............1 Scale Vacuum pump for R32, R410A 2. OUTDOOR UNIT INSTALLATION ..........7 Utility knife or scissors Charge hose for R32, R410A 3.
  • Page 4 / for multi system multi-system 3-core 4-core MXZ-6F122VF 220-230-240 V 50 Hz 32 A 25 m / 80 m 15 m 25 / 80 55 dB (A) 57 dB (A) 4.0 mm 1.0 / 1.5 mm...
  • Page 5 FREE SPACE REQUIRED AROUND OUTDOOR UNIT Obstacles above Front (blowing) side open When there is no obstacle in front and As long as space indicated 100 or more on the sides of the unit, it is allowed in the figure is provided, it 200 or more to install the unit where an obstacle is is allowed to install the unit...
  • Page 6 1-4-1. Minimum installation area for Outdoor units If you unavoidably install a unit in a space where all four sides are blocked or there are depressions, confirm that one of these situations (A, B or C) is satisfied. Note: These countermeasures are for keeping safety not for specification guarantee. A) Secure sufficient installation space (minimum installation area Amin).
  • Page 7 1-4-2. Minimum installation area for Indoor units Install in a room with a floor area of Amin or more, corresponding to refrigerant quantity M (factory-charged refrigerant + locally added refrigerant). Install the indoor unit so that the height from the floor to the bottom of the indoor unit is h0; for wall mounted: 1.8 m or more;...
  • Page 8 1-5. INSTALLATION DIAGRAM After the leak test, apply insulat- ing material tightly so that there ACCESSORIES is no gap. Check the following parts before installation. (1) Drain socket When the piping is to be attached to (2) Drain cap a wall containing metals (tin plated) or metal netting, use a chemically treated wooden piece 20 mm or PARTS TO BE PROVIDED AT YOUR SITE...
  • Page 9: Outdoor Unit Installation

    2. OUTDOOR UNIT INSTALLATION 2-1. INSTALLING THE UNIT • Be sure to fix the unit’s legs with bolts when installing it. • Be sure to install the unit firmly to ensure that it does not fall by an earthquake or a gust. •...
  • Page 10: Flaring Work And Pipe Connection

    3. FLARING WORK AND PIPE CONNECTION 3-1. PRECAUTIONS FOR DEVICES THAT USE R32 REFRIGERANT • Use ester oil, ether oil, alkylbenzene oil (small amount) as the refrigeration oil applied to the flared sections. • Use C1220 copper phosphorus, for copper and copper alloy seamless pipes, to connect the refrigerant pipes. Use refrigerant pipes with the thicknesses specified in the table to the below.
  • Page 11: Purging Procedures, Leak Test, And Test Run

    4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN 4-1. PURGING PROCEDURES AND LEAK TEST 1) Remove service port cap of stop valve on the side of the outdoor unit gas pipe. Compound pressure gauge (for R32, R410A) (The stop valves are fully closed and covered in caps in their initial state.) –0.101MPa *4 to 5 turns (–760 mmHg)
  • Page 12 4-3. LOCKING THE OPERATION MODE OF THE AIR CONDITIONER (COOL, DRY, HEAT) • Description of the function: With this function, once the operation mode is locked to either COOL/DRY mode or HEAT mode, the air conditioner operates in that mode only. * Changing the setting is required to activate this function.
  • Page 13: Pumping Down

    4-7. TEST RUN • Test runs of the indoor units should be performed individually. See the installation manual coming with the indoor unit, and make sure all the units operate properly. • If the test run with all the units is performed at once, possible erroneous connections of the refrigerant pipes and the indoor/outdoor unit connecting wires cannot be detected.
  • Page 14 Information of spec name plate...
  • Page 15 EG-DEKLARATION OM ÖVERENSSTÄMMELSE KUUTUS MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD 700/406 MOO 7, TAMBON DON HUA ROH, AMPHUR MUANG, CHONBURI 20000, THAILAND hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das häusliche, kommerzielle und leicht-industrielle Umfeld wie unten beschrieben:...
  • Page 16 Travellers Lane, Hatfield, Herts., AL10 8XB, England, U.K. Polish Branch Krakowska 50, PL-32-083 Balice, Poland MITSUBISHI ELECTRIC TURKEY ELEKTRİK ÜRÜNLERI A.Ş. Şerifali Mah. Kale Sok. No: 41 34775 Ümraniye, İstanbul / Turkey HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN...