Self Diagnostic Function - Sony TRINITRON KV-DA322M64 Service Manual

Table of Contents

Advertisement

The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER lamp will automatically
begin to flash.
The number of times the lamp flashes translates to a probable source of the problem. If an error symptom cannot be
reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past
problems and how often these problems occur.
1. DIAGNOSTIC TEST INDICATORS
When an error occurs, the STANDBY/TIMER lamp will flash a number of times to indicate the possible cause of the
problem. If there is more than one error, the lamp will identify the first of the problem areas.
Result for all of the following diagnostic items are displayed on screen. No error has occured if the screen displays a "0".
Diagnostic
No. of times
Item
STANDBY/TIMER
Description
lamp flashes
• Power does not
Does not light
turn on
• +B overcurrent
2 times
(OCP)
• Horizontal
deflection failure
• +B overvoltage
3 times
(OVP)
• Vertical deflection
4 times
failure
• White balance
5 times
failure (no
PICTURE)
• 5V/9V failure
8 times
• Micro reset
2. STANDBY INDICATOR BLINKING PROCESS
Lamp ON 300ms
Lamp OFF 300ms
Lamp OFF 3 seconds
The example above represents for 4 times blink

SELF DIAGNOSTIC FUNCTION

Self-diagnostic
display/Diagnostic
result
002:000 or
002:001~255
003:000 or
003:001~255
004:000 or
004:001~255
005:000 or
005:001~255
008:000 or
008:001~225
101:00 or
101:001~225
Probable
Cause
Location
• Power cord is not plugged
in.
• Fuse is burned out F1601
(F1 Board)
• H.OUT Q6802 is shorted.
• PH6602 faulty.
D6644 faulty
• 11V is not supplied.
(D board)
• V.OUT IC6801 faulty
D6827 faulty
D6817 faulty
• G2 is improperly adjusted.
• CRT problem.
• Video OUT IC9001, 9002,
9003 are faulty. (C board)
• IC4301 CXA2170Q (A
board) are faulty.
• 5V regulator (IC2601) faulty.
• 9V regulator (IC2600) faulty.
• CRT Discharge (C Board)
• Static discharge
• External noise
3. STANDBY INDICATOR ON TV FRONT PANEL
Standby indicator
– 3 –
KV-DA322M64/M66
Detected
Symptoms
• Power does not turn on.
• No power is supplied to the
TV.
• AC power supply is faulty.
• Power does not turn on.
• Load on power line is
shorted.
• H pulse output is too high.
• Power does not come on.
• Vertical deflection pulse is
stopped.
• Vertical size is too small.
• Vertical deflection stopped.
• No raster is generated.
• CRT cathode current
detection reference pulse
output is small.
• TV Blank
• No Raster
• Power is shut down shortly,
after this return back to
normal.
• Detect Micro latch up.
RM-GA001