WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
4. Check the scope of delivery by comparing your order to the shipping documents for correctness and completeness. WARNING Using a damaged or incomplete device Risk of explosion in hazardous areas. • Do not use damaged or incomplete devices. SITRANS FS230 A5E38755607-AA, 02/2017...
The contents of this manual shall not become part of or modify any prior or existing agreement, commitment or legal relationship. The sales contract contains all obligations on the part of Siemens as well as the complete and solely applicable warranty conditions.
Risk to personnel, system and environment can result from modifications to the device, particularly in hazardous areas. • Only carry out modifications that are described in the instructions for the device. Failure to observe this requirement cancels the manufacturer's warranty and the product approvals. SITRANS FS230 A5E38755607-AA, 02/2017...
Operation under special ambient conditions We highly recommend that you contact your Siemens representative or our application department before you operate the device under special ambient conditions as can be encountered in nuclear power plants or when the device is used for research and development purposes.
The device can overheat or materials become brittle due to UV exposure. • Protect the device from direct sunlight. • Make sure that the maximum permissible ambient temperature is not exceeded. Refer to the information in Technical data (Page 21). SITRANS FS230 A5E38755607-AA, 02/2017...
Orientation for Single path sensor at the 9 o'clock position ⑤ ⑩ Spacer bar Orientation for Dual path sensor at the 10 and 2 o'clock positions Figure 3-2 Reflect mount Terminal Layout Figure 3-3 Terminal layout - wall mount housing SITRANS FS230 A5E38755607-AA, 02/2017...
If the device contains hazardous media, it must be emptied prior to disassembly. Make sure that no environmentally hazardous media are released. • Secure the remaining connections so that no damage can result if the process is started unintentionally. SITRANS FS230 A5E38755607-AA, 02/2017...
Page 11
Risk of explosion in hazardous areas as result of incorrect power supply, e.g. using direct current instead of alternating current. • Connect the device in accordance with the specified power supply and signal circuits. The relevant specifications can be found in the certificates, in Technical data (Page 21) or on the nameplate. SITRANS FS230 A5E38755607-AA, 02/2017...
Page 12
You can use this device in industrial environments, households and small businesses. For metal housings there is an increased electromagnetic compatibility compared to high-frequency radiation. This protection can be increased by grounding the housing, see Technical data (Page 21). SITRANS FS230 A5E38755607-AA, 02/2017...
Page 13
3. Place F-connector tool around cable and slide up to engage F-connector nut. 4. Push cable through gland opening. Ensure that center lead is aligned with connector port in transmitter. 5. Tighten F-connector using tool until you meet mechanical stop. SITRANS FS230 A5E38755607-AA, 02/2017...
Page 14
6. Remove F-connector tool. 7. Mount and tighten cable gland. Repeat these steps for each sensor cable. SITRANS FS230 A5E38755607-AA, 02/2017...
Upstream sensor cable (1A) Path 1 Sensors ③ Flow direction Figure 4-2 Wall mount housing with transmitter-to- sensor cable connections 5. Tighten all cable glands to obtain optimum sealing. 6. Refer to transmitter FST030 Operating Instructions to program transmitter. SITRANS FS230 A5E38755607-AA, 02/2017...
Page 16
Upstream sensor cable to internal DSL port Downstream sensor cable to transmitter port (1B) Path 1 (1A) Path 1 ⑤ Hi Precision mounted sensors Figure 4-3 Hi Precision Reflect mount single enclosure wiring 5. Tighten all cable glands to obtain optimum sealing. SITRANS FS230 A5E38755607-AA, 02/2017...
Page 17
③ ② 3. Observing the upstream and downstream orientation , connect upstream sensor cable to transmitter port (1A) and make connection snug. ⑤ 4. Connect downstream sensor cable to transmitter port (1B) and make connection snug. SITRANS FS230 A5E38755607-AA, 02/2017...
Page 18
Downstream sensor cable to transmitter port (1B) Path 1 Figure 4-4 HI Precision Direct mount Dual enclosure sensor wiring 5. Tighten all cable glands to obtain optimum sealing. 6. Refer to transmitter FST030 Operating Instructions to program transmitter. SITRANS FS230 A5E38755607-AA, 02/2017...
Page 19
Damage to device if the enclosure is open or not properly closed. The type of protection specified on the nameplate or in Technical data (Page 21) is no longer guaranteed. • Make sure that the device is securely closed. SITRANS FS230 A5E38755607-AA, 02/2017...
Successful operation of the key is confirmed by a small green LED at the right of the display. ① Full graphical display ② LED (for indication of key operation) ③ Touch keypad Figure 5-1 Local display SITRANS FS230 A5E38755607-AA, 02/2017...
Set date and time The set date and time (real time clock) is used for all time stamps of logged information Quick commissioning The Quick commissioning wizard comprises the most important parameters/menus for quick configuration of the flowmeter SITRANS FS230 A5E38755607-AA, 02/2017...
95 % Bump resistance On request Shock resistance On request Thermal shock On request Vibration resistance On request • • Emission EN 55011 / CISPR-11 EMC performance • • Immunity EN/IEC 61326-1 (Industry) NAMUR NE 21 SITRANS FS230 A5E38755607-AA, 02/2017...
Page 23
0 to 160 bar (0 to 2321 psi) Process medium absolute pressure (min to max) Stainless steel: 1 to 101 bar (14.5 to 1465 psi) Hastelloy: 1 to 161 bar (14.5 to 2335 psi) Process medium viscosity Gases and non-compressible liquids SITRANS FS230 A5E38755607-AA, 02/2017...
● Seal integrity of the process connections, cable entries, and cover screws ● Reliability of power supply, lightning protection, and grounds NOTICE Repair and service must be carried out by Siemens authorized personnel only. Note Siemens defines flow sensors as non-repairable products.
Risk of burns during maintenance work on parts having surface temperatures exceeding 70 °C (158 °F). • Take corresponding protective measures, for example by wearing protective gloves. • After carrying out maintenance, remount touch protection measures. SITRANS FS230 A5E38755607-AA, 02/2017...
Enclose the bill of lading, return document and decontamination certificate in a clear plastic pouch and attach it firmly to the outside of the packaging. Required forms ● Delivery note ● Return goods delivery note (http://www.siemens.com/processinstrumentation/returngoodsnote) with the following information: – Product (item description) –...
Page 27
DVD. Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.