hit counter script

Physical Interface-Related Commands - Hitachi GX1000-SMC013X Instruction Manual

Table of Contents

Advertisement

22.1.5 Physical interface-related commands

ipaddress
Description
This command assigns the IP addresses for Ethernets.
Execute this command in the
Syntax
To set information:
ipaddress {A.B.C.D/M|X:X::X:X/M}
To delete information:
delete ipaddress {all|A.B.C.D/M|X:X::X:X/M}
Parameters
A.B.C.D
Specifies the internal network IPv4 address to be set.
Specify the IPv4 address in dot notation.
1.
2.
M
Specifies the internal network IPv4 prefix to be set.
1.
2.
X:X::X:X
Specifies the internal network IPv6 address to be set.
Specify the IPv6 address in colon notation.
1.
2.
M
Specifies the internal network IPv6 prefix to be set.
1.
260
ethernet
Default value when this parameter is omitted:
None (this parameter cannot be omitted).
Range of values:
0.0.0.1 to 255.255.255.255
Default value when this parameter is omitted:
None (this parameter cannot be omitted).
Range of values:
0 to 32
Default value when this parameter is omitted:
None (this parameter cannot be omitted).
Range of values:
0000:0000:0000:0000:0000:0000:0000:0000 to ffff:ffff:ffff:ffff:ffff:ffff:ffff:ffff
Default value when this parameter is omitted:
None (this parameter cannot be omitted).
level of configuration definition mode.

Advertisement

Table of Contents
loading

Table of Contents