hit counter script

Advertisement

Quick Links

Echolife ONT
Safety Information
To use the device properly and safely, read the safety precautions carefully before using the device and
strictly observe these precautions when using the device.
Safety precautions:
l Store devices and accessories in temperature –10°C to +35°C and relative humidity 30%–85%
RH for at most 9 months. If the ambient temperature or relative humidity is overhigh or overlow,
the device may be faulty.
l Used only indoors. Do not lead metallic cables, such as network cables and telephone lines
outdoors.
l Do not look directly into the optical port without eye protection.
l Keep the device out of the reach of children as the components or accessories may be
swallowed.
l Install the device in strict compliance with the requirements of the supplier. Reserve a space of at
least 10 cm above and around the device for heat dissipation. During the installation, keep the
device away from electric appliances that generate strong magnetic or electric fields, such as
microwave ovens, refrigerators, and mobile phones.
l The described input voltage range should comply with the local power grid. For example, the
input voltage of the adapter is 200–240 V AC for European Union; the input voltage of the
adapter is 100–140 V AC for America.
l If the power adapter is damaged and its internal circuit is exposed due to manmade factors, do
not touch the exposed circuit, which may bring safety risks.
l Only power adapters delivered with the device can be used. Otherwise, the device may be
abnormal or unsecure.
l Dry your hands before connecting or disconnecting cables. Stop the device and switch off the
power before connecting or disconnecting cables.
l Do not place any object on the device, so that the device will not be damaged due to overheating
or deformation.
l Prevent objects, such as metal, from entering the device through the heat dissipation hole.
l Switch off the power and disconnect all cables, including the power cable, optical fiber, and
network cable, during periods of lightning activities. The socket-outlet shall be installed near the
power adapter and shall be easily accessible. Before use the power adapter, please check no
damage on the adapter.
l Do not lead the strength member of the optical fiber or other metal parts indoors. Do not install
telephone lines, network cables, power adapters or power adapter cables outdoors. Adopting
these measures will help prevent device damage and bodily injuries which are especially prone
during thunderstorms.
l If an abnormality occurs, for example, liquid entering the device, smoke, unusual sound, and
smell, stop the device immediately, switch off the power, disconnect all cables (such as the
power cable, optical cable, and network cable) to the device, and contact the authorized service
center.
l Do not disassemble the device without permission. In the case of a device fault, contact the
authorized service center.
l Dispose of the packing materials, expired batteries, and old or abandoned devices in accordance
to local laws and regulations (recycling them is strongly recommended).
l Do not change the structure, safety design, or performance design of the device without prior
authorization.
l The device should be installed and operated with a minimum distance of 20 cm between the
radiator and your body.
Quick Start
1

Advertisement

Table of Contents
loading

Summary of Contents for Huawei Echolife HG8245Q5

  • Page 1 Quick Start Echolife ONT Safety Information To use the device properly and safely, read the safety precautions carefully before using the device and strictly observe these precautions when using the device. Safety precautions: l Store devices and accessories in temperature –10°C to +35°C and relative humidity 30%–85% RH for at most 9 months.
  • Page 2: Laser Safety

    Fireproof precautions: l Keep the device away from large heat source equipment, bare flames, and high-power devices, such as electric heaters, candles, and blow drier, to eliminate safety risks. l If there are aged cables or power socket facilities on the power supply line to or near the device, replace them in time to eliminate safety risks.
  • Page 3: Product Overview

    The devices that support Wi-Fi access are classified into devices equipped with external antennas and devices equipped with internal antennas. If some device types are not in the preceding list, refer to http://www.huawei.com. Technical Specifications Power adapter input: 100–240 V AC, 50/60 Hz System power supply: See the nameplate on the device.
  • Page 4 4. After the PON terminal is installed with a foot-stand, do not remove the foot-stand unless it is necessary. When you remove the foot-stand, apply force evenly on the two sides of the foot-stand to avoid damages to the PON terminal. 5.
  • Page 5: Connecting Cables

    NOTE This terminal is mainly placed horizontally on a desk. When it is mounted onto a wall, the silkscreen of its indicator is reversed. If you have a special requirement on the silkscreen, purchase another terminal. Connecting Cables Ports on GPON terminals of all types may be different. Therefore, connect cables based on the ports that are actually supported by the device.
  • Page 6 Optical port 1. Power switch 2. Power port 3. USB port 4. POTS port 5. Ethernet port 6. CATV port 7. Reset 8. WLAN switch 9. WPS switch 10. Optical port Logging in to the Web Configuration Window Step 1 Set the IP address of the PC in the same subnet as the management IP address of the PON terminal.
  • Page 7 Configuring Wi-Fi Parameters Step 1 Choose the WLAN tab and choose WLAN Basic Configuration. NOTE If the ONT supports 2.4 GHz wireless and 5 GHz wireless , Choose the WLAN tab and choose 2.4G Basic Network Settings. (If you want to configure 5G Wi-Fi, choose 5G Basic Network Settings.) Step 2 In the pane, select the Enable WLAN option box.
  • Page 8: Indicator Description

    Indicator Description Table 1-1 Indicator status description 1 Indicator Status Description The CATV function is enabled and CATV signals are Always on received. CATV The CATV function is disabled or CATV signals are not received. Steady on The WPS function is enabled. Blinking A Wi-Fi terminal is accessing the system.
  • Page 9: Fcc Statement

    Table 1-2 Indicator status description 2 Status Description Status The PON terminal is prohibited by the upper-layer device or blinks abnormally, contact the service Blinks twice a Blinks twice a provider for help. second second Blinks twice a The PON terminal attempts to set up a second connection with its upper-layer device.
  • Page 10: Fcc Radiation Exposure Statement

    FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
  • Page 11: Qualification Card

    Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Issue: 02 (2018-06-07) BOM number: 3150xxxx...
  • Page 12: Warranty Card

    Warranty Card Thank you for choosing Huawei T echnologies Co., Ltd. T o get better services, please read this warranty card carefully, fill in the required information, and preserve this card in good condition. User Information Personal or Company's full name:...
  • Page 13: Limited Warranty

    In any case that is not covered by this limited warranty or should the warranty expire, Huawei shall charge for the service(s) claimed for the products if the product is still remediable. Huawei reserves all rights to interpret this limited warranty.

This manual is also suitable for:

Echolife hg8247q5

Table of Contents