Mothballing the turbocharger
Taking the engine out of operation for
up to 12 months
If the total acid number (TAN) is greater than 2 mg KOH/g, the following
mothballing measures are necessary after taking an engine out of operation:
Dismantle the turbocharger.
τ
The rotor and the bearing parts must be removed by an official ABB
τ
Turbocharging service station and refitted afterwards.
Clean all parts.
τ
Machined, bright surfaces of steel and cast parts must be oiled with
τ
anticorrosive oil.
Reassemble complete turbocharger.
τ
Rotor turning in stack draught
If the rotor turns as a result of the stack draught:
Install blind flange between compressor casing outlet flange and
τ
charge air duct.