Page 1
Operation Manual TPL65VA33 ABB Turbo Systems Ltd CH 5401 Baden Type TPL65VA33 HT578832 Mmax Mmax °C Bmax Bmax 01210 Application according to Year 2017 the Operation Manual made in Switzerland ABB Turbocharging...
Page 2
In case the operation conditions differs signifi cantly from what is considered to be normal for the cur- rent application, it is recommended to contact ABB for a re-calculation of replacement intervals. Frequent load alterations, high temperatures and high speed lower the life of components.
Operation Manual This Operation Manual enables you to familiarize yourself with the turbo- charger supplied by ABB Turbo Systems and to use it as intended. It provides important information in order that the turbocharger can be op- erated safely, correctly and efficiently.
Any other use will be regarded as a special application which must first be discussed with ABB Turbo Systems. The manufacturer accepts no liability for other applications. If it is used otherwise, ABB Turbo Sys- tems reserves the right to reject all warranty claims.
Storage of new turbochargers and spare parts up to 6 months New turbochargers and spare parts from ABB Turbo Systems can be stored in sealed packaging without additional mothballing measures for up to 6 months from the date of delivery (marked by the VCI label on the package).
Page 13
Page 11 spare parts Long-term storage of replacement turbochargers or spare parts Per order, turbochargers or cartridge groups will be prepared by ABB Tur- bo Systems for prolonged storage. The package is equipped with a hygrometer (see illustration). The following measures are required every 6 months: Check the hygrometer (02) in the sight-glass.
Page 15
Only use original parts from ABB Turbo Systems. ABB Turbo Systems accepts no liability for any damage resulting from the use of non-original parts and corresponding accessories. Competence of personnel The turbocharger must only be operated and serviced by trained and au- thorised personnel.
Page 16
This document is valid for different design variants of turbochargers. There may be sections and descriptions of components that are not rele- vant for a specific turbocharger variant. ABB Turbocharging Service Stations will be happy to provide information on questions regarding a design variant (see Contact information at www.abb.com/turbocharging).
Definition of caution / warning The caution and warning signs are described in the chapter Safety. ABB Turbo Systems In this document, ABB Turbo Systems Ltd is abbreviated to ABB Turbo Systems. Official ABB Turbo Systems Service Stations In this document, official service stations are referred to as ABB Turbo- charging Service Stations.
Page 19
A rating plate is attached to the turbocharger foot, one on the left and one on the right. In the case of turbochargers with insulation supplied by ABB Turbo Systems, at least one additional rating plate is attached to the insu- lation of the gas outlet casing.
Operation Manual / TPL65VA32/33 Preliminary remarks Contact information Page 18 Contact information Contact information Contact information for the official service stations of ABB Turbo Systems is available online. Scan the QR code to access our website. ABB Turbo Systems Ltd Bruggerstrasse 71a...
Page 19 Safety Introduction Turbochargers manufactured by ABB Turbo Systems are state of the art and comply with the pertinent safety and health-protection requirements that applied when the turbocharger was manufactured. Consequently, the turbocharger is safe to operate. Nevertheless, during turbocharger opera- tion and when working on the turbocharger, residual risks can exist which: ...
Warning plates on the turbocharger Page 21 Warning plates on the turbocharger Warnings that have been attached to turbochargers by ABB Turbo Sys- tems must not be removed. Illegible warnings must be replaced with new ones. Further information is available from ABB Turbocharging service stations.
Page 28
Wear safety gloves against thermal risks. Hot surfaces on uninsulated turbochargers Uninsulated turbochargers can cause serious personal injuries (burns). The turbocharger is supplied by ABB Turbo Systems without insulation WARNING depending on the order from the engine builder. In this case, the engine builder is responsible for insulating the turbocharger properly or for providing protection against hot surfaces being touched.
Heed any country-specific regulations. Periodic checking of the pressure vessel The pressure vessels used by ABB Turbo Systems, such as those for wet or dry cleaning, are so-called "simple pressure vessels". The local, statutory regulations covering periodic checks of pressure vessels must be observed.
Page 39
The first step is NOTICE to check the seal for the oil supply to the turbocharger. If this is not in proper condition, contact an official ABB Turbocharging service station. 3.2.4 Inspection after 100 service hours Clean or replace lubricating oil filters after the first 100 service hours.
Despite observance of the service intervals, unusual loads, such as several start-stops a day, harsh environmental factors, poor fuel quality CAUTION or heavy installation vibration can lead to premature machine damage. A shortened service interval must be arranged with ABB Turbo Sys- tems. Service inspection after 5 years...
Page 45
(Customer Part Exchange) programme. 4.2.5 Service work every 30000 hours The replacement of bearing parts as well as the inspection and assess- ment of the rotor must be carried out by an ABB Turbocharging Service Station. Disassemble turbocharger. Measure clearances.
Page 61
Cleaning of the compressor during operation is carried out using the cleaning method described in the following: Wet cleaning This cleaning method has been tested and approved by ABB Turbo Sys- tems. To clean the compressor stage during operation, water is injected in front...
Page 62
If the cleaning is still unsuccessful after three cleaning processes and the engine values are unsatisfactory, it is recommended to have the turbo- charger checked and cleaned by an ABB Turbocharging Service Station. Cleaning parameters per turbocharger compressor Product...
Page 63
Operating state prerequisites for wet cleaning XC3 To be able to carry out a satisfactory cleaning process which has been tested and is recommended by ABB Turbo Systems, the following pre- requisites must be fulfilled: Engine load 50 ... 85% ...
Page 64
If the cleaning results are still not satisfactory after three attempts and the engine values are also unsatisfactory, we recommend that you have NOTICE the turbocharger inspected and cleaned by an official ABB Turbocharg- ing Service Station. Cleaning parameters per turbocharger compressor...
(see chapter entitled Service work). Professional overhauling of the components by an ABB Turbocharging Service Station is required, preferably using the cleaning method de- scribed in the following.
Certain tolerances must be observed to avoid a significant loss of efficiency. If there is any doubt about the extent of rubbing, then an ABB Turbocharging Service Station must be contacted. Have a dimension check carried out by an ABB Turbocharging Service Station.
Possible damage to components, such as the compressor wheel, tur- bine blades, bearings and filter silencer CAUTION Have the cause clarified immediately by an ABB Turbocharging ser- vice station and rectified. Have components inspected for damage and, if necessary, replaced ...
This problem is eliminated by removing the gasket. Defective sensor Contact ABB Turbocharging service station. Measured Dirty sensor tip The sensor tip is magnetic and can thus at- speeds too tract metal particles.
CAUTION Only carry out those tasks that are described in this chapter. Marking casing positions for assembly ABB Turbo Systems recommends that the casing positions are marked before disassembling the turbocharger. NOTICE Identifying assembly devices Not all assembly devices are marked with a part number. They can be identified using the tool list.
Carefully separate gas inlet casing (51001) from variable turbine ge- ometry module (56100) and remove it. Have the variable turbine geometry module overhauled by ABB Turbo Systems. ABB Turbocharging Service Stations have variable turbine geometry modules replaced with overhauled ones as part of the CPEX (Customer Part Exchange) programme.
Page 105
Clearances out of tolerance and excessively worn components can be the cause of serious damage to machinery and property. CAUTION Have components assessed and, if necessary, replaced by an ABB Turbocharging Service Station. Connect oil lines and all air lines in accordance with engine builder’s ...
Page 116
Dismantle the turbocharger. The rotor and the bearing parts must be removed by an official ABB Turbocharging service station and refitted afterwards. Clean all parts. ...
Page 117
The turbocharger remains mounted on the engine. The turbocharger casing remains mounted on the engine, but the rotor and the bearing parts are removed and stored separately by an ABB Turbocharging Service Station. The turbocharger is removed completely, either as a whole or in indi- vidual parts.
Page 121
Turbocharger type Serial number (HT……) Description and part number Spare parts can be ordered from an official ABB Turbocharging Service Station. If different design versions have not been taken into consideration in this document, please contact an ABB Turbocharging Service Station.