Cisco 5000 Series Hardware Installation Manual
Cisco 5000 Series Hardware Installation Manual

Cisco 5000 Series Hardware Installation Manual

Platform and switch
Hide thumbs Also See for 5000 Series:
Table of Contents

Advertisement

Quick Links

S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m
Cisco Nexus 5500 Platform and 5000 Series Switch

Hardware Installation Guide

December 2010
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel:
408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Text Part Number: OL-15902-01

Advertisement

Table of Contents
loading

Summary of Contents for Cisco 5000 Series

  • Page 1: Hardware Installation Guide

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Cisco Nexus 5500 Platform and 5000 Series Switch...
  • Page 2 OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at www.cisco.com/go/trademarks.
  • Page 3: Table Of Contents

    Fibre Channel Plus Ethernet Expansion Module Ethernet Expansion Module N5K-M1008 Gatos Expansion Module N5K-M1060 Gatos Expansion Module Ports OL-15902-01 C O N T E N T S i-xvi 1-10 1-11 1-12 1-14 Cisco Nexus 5500 Platform and 5000 Series Switch Hardware Installation Guide 1-12...
  • Page 4 Installing the Cisco Nexus 5020 Chassis in a Cabinet or Rack Installing the Cisco Nexus 5010 Chassis in a Cabinet or Rack Grounding the System Proper Grounding Practices Preventing Electrostatic Discharge Damage Cisco Nexus 5500 Platform and 5000 Series Switch Hardware Installation Guide 2-11 2-12 2-14 2-16...
  • Page 5 Installing a Fan Module Removing a Fan Module Removing the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series Switch Repacking the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch for Return Shipment Connecting the Switch...
  • Page 6 Accessory Kit for the Cisco Nexus 5010 Switch Console Cable Cable RJ-45 Connector Pinouts Console Port Console Port Pinouts Supported Power Cords and Plugs Power Cords AC Power Cord Illustrations Jumper Power Cord Cisco Nexus 5500 Platform and 5000 Series Switch Hardware Installation Guide C-12 4-11 OL-15902-01...
  • Page 7 A P P E N D I X SNMP Traps Switch Hardware Best Practices Installation Best Practices Initialization Best Practices Switch Operation Best Practices N D E X OL-15902-01 Cisco Nexus 5500 Platform and 5000 Series Switch Hardware Installation Guide Contents...
  • Page 8 S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Cisco Nexus 5500 Platform and 5000 Series Switch Hardware Installation Guide...
  • Page 9: Preface

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Preface This preface describes the audience, organization, and conventions of the Cisco Nexus 5500 Platform and 5000 Series Switch Hardware Installation Guide. It also provides information on how to obtain related documentation. Audience To use this installation guide, you must be familiar with electronic circuitry and wiring practices and preferably be an electronic or electromechanical technician.
  • Page 10: Conventions

    BEWAAR DEZE INSTRUCTIES Cisco Nexus 5000 Series Hardware Installation Guide Description “Site Planning and Provides site planning and maintenance records. Provides installation troubleshooting information for the Cisco Nexus 5500 Platform switches and the Cisco Nexus 5000 Series switches. Preface OL-15902-01...
  • Page 11 å forhindre ulykker. Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten. TA VARE PÅ DISSE INSTRUKSJONENE OL-15902-01 Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 12 Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning. SPARA DESSA ANVISNINGAR Cisco Nexus 5000 Series Hardware Installation Guide OL-15902-01...
  • Page 13 Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER Cisco Nexus 5000 Series Hardware Installation Guide xiii OL-15902-01...
  • Page 14 S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 15 S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 16: Related Documentation

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Related Documentation The documentation set for the Cisco Nexus 5500 Platform switches and the Cisco Nexus 5000 Series switches includes the following documents: Regulatory Compliance and Safety Information for the Cisco Nexus 5000 Series and Cisco Nexus •...
  • Page 17: Cisco Nexus 5500 Platform Overview

    Cisco Nexus 5548P Switch, page 1-2 • Overview The Cisco Nexus 5548P switch, which is the first switch in the Cisco Nexus 5500 Platform, provides the following features: Standards-based 10-Gigabit Ethernet, FCoE, and virtual machine awareness features that allow you •...
  • Page 18: Chapter 1 Cisco Nexu 5500 Platform Overview

    • connections into a smaller number of server connections trunked to the aggregation layer. As a Layer 3 1-Gigabit and 10-Gigabit Ethernet switch, the switch can consolidate multiple 1- and • 10-Gigabit Ethernet connections from a data center access layer.
  • Page 19: Cisco Nexus 5548P Switch

    It is designed to be mounted in a standard 19-inch rack. The switch has two power supplies and two fans modules on the front of the switch. The switch also has one USB port (usb1:) at the front of the switch.
  • Page 20 Mgmt (10/100/1000) port, console port, and USB port Two fan modules The rear of the Cisco Nexus 5548P switch chassis has 32 fixed 10-Gigabit Ethernet ports and 1 slot for an optional expansion module. Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 21 S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m Figure 1-3 Cisco Nexus 5548 Switch Rear View 32 fixed 10-Gigabit Ethernet ports Expansion module Cisco Nexus 5000 Series Hardware Installation Guide OL-15902-01...
  • Page 22: Expansion Modules

    10-Gigabit Ethernet and FCoE ports or connect to Fibre Channel SANs with 1-, 2-, 4-, 8-Gbps Fibre Channel switch ports. The chassis supports hot swapping of the expansion modules. The Cisco Nexus 5548P supports one of the following expansion modulules: N55 M16P Gatos Expansion Module, page 1-6 •...
  • Page 23: N55 M8P8Fp Gatos Expansion Module

    SFP+ interface and 8 ports of 8-, 4-, 2-, 1 Gbps native Fibre Channel connectivity using the SFP interface. Figure 1-7 OL-15902-01 shows a front view of the expansion module. N55 M16P GEM shows the N55 M8P8FP expansion module. Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5548P Switch...
  • Page 24: Ports

    N55 M8P8FF expansion module. Figure 1-8 Ports Each individual port on the Cisco Nexus 5548P switch is numbered, and groups of ports are numbered based on their function. The ports are numbered from top to bottom and left to right. Figure 1-9...
  • Page 25: Power Supplies

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m Power Supplies The Cisco Nexus 5548 switch uses a front-end power supply. The chassis has slots for two power supplies. Two power supplies can be used for redundancy, but the Cisco Nexus 5548 switch is fully functional with one power supply.
  • Page 26: Fan Modules

    Heat dissipation Fan Modules The Cisco Nexus 5548 switch has slots for two fan modules. If you insert two fan modules with six fans in each module, your switch will have a total of 12 fans. Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 27: Led Descriptions

    Chassis Power/Health Amber Fan tray heath Green trays (front) indicator (multicolor) Amber Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5548P Switch Status Description Solid On System is on and operating normally Switch is powered off Fault condition Solid On...
  • Page 28: Connectivity Options-Transceivers And Cables

    Cisco SFP-10G-LR Cisco SFP-H10GB-CU1M Cisco SFP-H10GB-CU3M Cisco SFP-H10GB-CU5M Cisco GLC-T Cisco GLC-SX-MM Cisco GLC-LH-SM Cisco SFP-GE-T Cisco Nexus 5000 Series Hardware Installation Guide 1-12 LEDs for the Cisco Nexus 5548 Switch (continued) Location Function Color Power supply PSU Health Green...
  • Page 29: Sfp+ Transceivers

    8-Gbps Fibre Channel LW SFP+, LC (for Fibre Channel expansion module ports) Table 1-5 SFP+ Transceivers Description 10-Gigabit Ethernet—Short range SFP+ module 10-Gigabit Ethernet—Long range SFP+ module Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5548P Switch Table 1-6). The 1-13...
  • Page 30: Cables

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m Model SFP-H10GB-CU1M SFP-H10GB-CU3M SFP-H10GB-CU5M SFP Fiber Channel Transceivers The Cisco Nexus 5548 switch supports the multimode 850 nm 4Gbps SFP with 150 m reach. See Table 1-7. Model DS-SFP-FC4G-SW DS-SFP-FC4G-LW...
  • Page 31 Active Twinax 7 m/ ~ 0.5 W ~ 6.8 10 m MM OM2 82 m/ MM OM3 300 m Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5548P Switch Transceiver Latency (Link) Standard SFF 8461 nanoseconds IEEE 802.3ae...
  • Page 32 S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 33: Cisco Nexus 5010 Switch

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Cisco Nexus 5000 Series Overview This chapter describes the Cisco Nexus 5000 series switches. This chapter includes the following sections: Cisco Nexus 5020 Switch, page 2-1 •...
  • Page 34: Chapter 2 Cisco Nexus 5000 Series Overview

    19-inch rack. The switch has two power supplies and five fans modules on the front of the switch. Ports are at the rear of the switch. The airflow is front to back. Figure 2-1 shows the front of the Cisco Nexus 5020 switch.
  • Page 35 Cisco Nexus 5020 Switch Front View Close-up Figure 2-3 shows the rear of the Cisco Nexus 5020 switch. Cisco Nexus 5020 Switch Rear View Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5020 Switch System status LED 40 fixed 10-Gigabit Ethernet ports...
  • Page 36 The Ethernet connector port exposes four Ethernet ports that are in a 2x2 stacked RJ-45 jack. shows a close-up view of the Ethernet connector port. Figure 2-5 Internal cross connect ports Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5020 Switch Rear View Close-up Ethernet Connector Port Chapter 2...
  • Page 37: Expansion Modules

    Ethernet switches and as I/O consolidation platforms with native Fibre Channel connectivity. The Cisco Nexus 5020 switch has two slots that can be used for the following optional expansion modules: Fibre Channel plus Ethernet expansion module with four 10-Gigabit Ethernet Cisco Data Center •...
  • Page 38: Fibre Channel Plus Ethernet Expansion Module

    Fibre Channel plus Ethernet expansion module. Cisco Nexus 5000 Series Hardware Installation Guide Fibre Channel Plus Ethernet Expansion Module Front View of the Fibre Channel Plus Ethernet Expansion Module f...
  • Page 39: Ethernet Expansion Module

    N5K-M1008 GEM. OL-15902-01 Ethernet Expansion Module 10 GIGABIT ETHERNET for an illustration of how ports are grouped and numbered on the Ethernet expansion Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5020 Switch Figure 2-8 10-Gigabit Ethernet ports Figure 2-9...
  • Page 40: N5K-M1060 Gatos Expansion Module

    N5K-M1060 Gatos Expansion Module The N5K-M1060 xpansion module provides 6 EA 1/2/4/8G line rate Fiber Channel, SFP+ based uplink connections. Figure 2-11 Cisco Nexus 5000 Series Hardware Installation Guide N5K-M1008 GEM Front View of the N5K-M1008 GEM Figure 2-12 show the N5K-M1060 GEM.
  • Page 41: Ports

    Six 1-, 2-, 4-, 8-Gbps Fibre Channel ports Ports Each individual port on the Cisco Nexus 5020 switch is numbered, and groups of ports are numbered based on their function. The ports are numbered top to bottom and left to right. The 40 fixed ports form group 1 and are named 1/port_number.
  • Page 42 Ethernet expansion module ports. Figure 2-14 Cisco Nexus 5000 Series Hardware Installation Guide 2-10 Port Numbering of Fixed Ports and Fibre Channel Plus Ethernet Expansion Module...
  • Page 43: Power Supplies

    Ethernet ports Power Supply The Cisco Nexus 5020 switch uses a front-end power supply. The chassis has slots for two power supplies. Two power supplies can be used for redundancy, but the Cisco Nexus 5020 switch is fully functional with one power supply.
  • Page 44: Fan Modules

    Figure 2-16 Fan Modules The Cisco Nexus 5020 switch has five fan modules. Cisco Nexus 5000 Series Hardware Installation Guide 2-12 Power Supply LED Descriptions (continued) Blank Power Supply Filler Panele Chapter 2...
  • Page 45 S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m Figure 2-17 Cisco Nexus 5020 Fan Module Fan module LED The bicolor fan module LED indicates the fan tray health. Green indicates normal operation, while amber indicates a fan failure. Cisco Nexus 5000 Series Hardware Installation Guide 2-13 OL-15902-01...
  • Page 46: Led Descriptions

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m LED Descriptions Table 2-3 describes the LEDs for the Cisco Nexus 5020 switch. Table 2-3 Chassis Fan module Cisco Nexus 5000 Series Hardware Installation Guide 2-14 LEDs for the Cisco Nexus 5020 Switch Location Function Color Front and back...
  • Page 47 Amber Back of the Indicates Green chassis LED status Amber Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5020 Switch Status Description Solid on Power supply is on and okay. No AC power to the power supply. Solid on...
  • Page 48 S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m Supported SFP Transceivers The Cisco Nexus 5020 switch supports both SFP+ Ethernet transceivers and SFP Fibre Channel transceivers.
  • Page 49: Model

    The Cisco Nexus 5020 switch also supports the following SFP Fibre Channel transceivers (See Table 2-6) : Model DS-SFP-FC4G-SW Cisco Nexus 5010 Switch This section describes the Cisco Nexus 5010 switch and its components. This section includes the following topics: Features, page 2-18 • Chassis, page 2-18 •...
  • Page 50: Figure

    19-inch rack. The switch has two power supplies and two fans modules on the front of the switch. Ports are at the rear of the switch. The airflow is front to back. Figure 2-19 shows the front view of the Cisco Nexus 5010 switch.
  • Page 51 Cisco Nexus 5010 Switch Front View Close-up Figure 2-21 shows the rear of the Cisco Nexus 5010 switch. Cisco Nexus 5010 Switch Rear View Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5010 Switch Two fan modules System status LED...
  • Page 52 (top and bottom), and two network management ports on the right (top and bottom) Console port Cisco Nexus 5000 Series Hardware Installation Guide 2-20 Chapter 2 Cisco Nexus 5000 Series Overview 20 fixed 10-Gigabit Ethernet ports...
  • Page 53 Internal cross connect ports OL-15902-01 Cisco Nexus 5010 Switch Rear View Close-up Ethernet Connector Port Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5010 Switch Slot 1, with 20 fixed 10-Gigabit Ethernet ports (highlighted in red). Slot 2 for an optional expansion module...
  • Page 54 Ethernet switches and as I/O consolidation platforms with native Fibre Channel connectivity. The Cisco Nexus 5010 switch has one slot for an optional uplink Gatos Expansion Module (GEM). The following modules can be inserted in this slot: N5K-M1404, N5K-M1600, N5K-M1008 and N5K-M1060.
  • Page 55 N5K-M1404 Gatos Expansion Module Front of the N5K-M1404 GEM 10 GIGABIT ETHERNET 1/2/4G FIBRE CHANNEL Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5010 Switch Figure 2-13 shows how ports are numbered on Four 1-, 2-, 4-Gbps Fibre Channel ports...
  • Page 56: N5K-M1008 Gatos Expansion Module

    The N5K-M1008 GEM supports 8 1/2/4G Fiber Channel, SFP-based uplink connection. Figure 2-28 show the N5K-M1008 GEM. Figure 2-27 Cisco Nexus 5000 Series Hardware Installation Guide 2-24 N5K-M1600 GEM 10 GIGABIT ETHERNET for an illustration of how ports are grouped and numbered on the Ethernet expansion...
  • Page 57: N5K-M1060 Gatos Expansion Module

    The N5K-M1060 expansion module provides 6 EA 1-, 2-, 4-, 8-Gbps line rate Fiber Channel, SFP+ based uplink connections. Figure 2-29 OL-15902-01 Front View of the N5K-M1008 GEM Figure 2-27 shows the N5K-M1060 GEM. N5K-M1060 GEM Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5010 Switch 2-25...
  • Page 58 The ports are numbered top to bottom and left to right. There are 20 to 28 ports on the Cisco Nexus 5010 switch, depending on which GEM is installed. The 20 fixed ports form group 1 and are named 1/port_number. Ports 1 through 16 are unencrypted Ethernet ports.
  • Page 59 Port Numbering of the Cisco Nexus 5010 Switch with the N5K-M1600 GEM Port Numbering of the Cisco Nexus 5010 Switch with the N5K-M1008 GEM Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5010 Switch Group 2, ports 1 through 4: Encrypted...
  • Page 60: Power Supplies

    Ethernet ports Power Supplies The Cisco Nexus 5010 switch uses a front-end power supply. The chassis has slots for two power supplies. Two power supplies can be used for redundancy, but the Cisco Nexus 5010 switch is fully functional with one power supply.
  • Page 61 Fan Modules The Cisco Nexus 5010 switch has slots for two fans modules. Each fan module houses six fans. If you insert 2 fan modules (with 6 fans in each module), your switch will have a total of 12 fans.
  • Page 62: Led Descriptions

    Table 2-9 describes the LEDs for the Cisco Nexus 5010 switch. Table 2-9 Power LED Fan Tray Status Cisco Nexus 5000 Series Hardware Installation Guide 2-30 Cisco Nexus 5010 Fan Module LEDs for the Cisco Nexus 5010 Switch Location Function...
  • Page 63: Port Level Leds

    PSU Status Indicators Health Indicator Port Level LEDs There are 20 to 26 port activity LEds on the switch depending on whether the GEM is a Fibre Channel or 10-Gigabit Ethernet module. Link State Link Down POST failed on port...
  • Page 64: Sfp+ Transceivers

    5m, 26-28 AWG • Model SFP-H10GB-CU1M SFP-H10GB-CU3M SFP-H10GB-CU5M SFP Fiber Channel Transceivers The Cisco Nexus 5010 switch supports the multimode 850nm 4Gbps SFP with 150m reach. See Table 2-13. Model DS-SFP-FC4G-SW DS-SFP-FC4G-LW Cisco Nexus 5000 Series Hardware Installation Guide 2-32...
  • Page 65: Installing The Cisco Nexus 5500 Platform Or 5000 Series Switch

    • Removing and Installing Components, page 3-22 • Repacking the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch for Return • Shipment, page 3-31 Before you install, operate, or service the system, see the Regulatory Compliance and Safety Information Note for the Cisco Nexus 5000 Family for important safety information.
  • Page 66: C H A P T E R 3 Installing The Cisco Nexus 5500 Platform Or 5000 Series Switch

    Airflow Considerations Airflow through the Cisco Nexus 5548P switch or the Cisc Nexus 5000 Series switch is from front to back. Air enters the chassis through the fan trays and power supplies mounted at the front of the chassis and exits the chassis through perforations on the rear of the chassis.
  • Page 67: Chassis Weight

    Lift the system slowly, keeping your back straight. Lift with your legs, not with your back. Bend at • the knees, not at the waist. Installation Guidelines When installing the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch, follow these guidelines: Plan your site configuration and prepare the site before installing the chassis. •...
  • Page 68: Required Equipment

    Grounding cable (6 AWG recommended), sized according to local and national installation • requirements; the required length depends on the proximity of the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch to proper grounding facilities Crimping tool large enough to accommodate girth of lug •...
  • Page 69: Installing The Cisco Nexus 5548 Chassis In A Cabinet Or Rack

    Installing the Cisco Nexus 5548 Chassis in a Cabinet or Rack This section describes how to use the rack-mount kit provided with the switch to install the Cisco Nexus 5548 switch into a cabinet or rack that meets the requirements described in Rack Installation.”...
  • Page 70 S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m To install the switch in a cabinet or rack using the rack-mount kit provided with the switch, follow these...
  • Page 71: Installing The Cisco Nexus 5020 Chassis In A Cabinet Or Rack

    Insert the switch into the rack as follows: Step 4 Using both hands, position the switch with the back of the switch between the front posts of the rack. Align the two rack-mount guides on either side of the switch with the slider rails installed in the rack.
  • Page 72 10-32 x 3/4-inch Phillips countersunk screws Slider rails (22 inch minimum to a 36 inch maximum) To install the switch in a cabinet or rack using the rack-mount kit provided with the switch, follow these steps: Install the front rack-mount brackets as follows:...
  • Page 73 Insert the switch into the rack: Step 4 Using both hands, position the switch with the back of the switch between the front posts of the rack. Align the two rack-mount guides on either side of the switch with the slider rails installed in the rack.
  • Page 74 S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m Figure 3-5 Stabilize the switch in the rack by attaching the front rack-mount brackets to the front rack-mounting Step 5...
  • Page 75: Installing The Cisco Nexus 5010 Chassis In A Cabinet Or Rack

    Table 3-3 Quantity To install the switch in a cabinet or rack using the rack-mount kit provided with the switch, follow these steps: Install the front rack-mount brackets as follows:...
  • Page 76 M4 screws. Repeat with the other rack-mount bracket on the other side of the switch. Attach the slider rails to the rack. This procedure is the same as that for the Cisco Nexus 5020 switch. Step 3 Figure 3-4.
  • Page 77: Grounding The System

    Grounding the System This section describes the need for system grounding for the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switchand explains how to prevent damage from electrostatic discharge. This section includes the following topics: Proper Grounding Practices, page 3-13 •...
  • Page 78 This building contains a standard office environment. Cisco Nexus 5000 Series Hardware Installation Guide 3-14 Chapter 3 Installing the Cisco Nexus 5500 Platform or 5000 Series Switch Electromagnetic Noise Severity Level Grounding Recommendations High All lightning protection devices...
  • Page 79: Preventing Electrostatic Discharge Damage

    ESD grounding straps are available with banana plugs, metal spring clips, or alligator clips. All • chassis from the Cisco Nexus 5500 Platform or from the Cisco Nexus 5000 Series switches are equipped with a banana plug connector (identified by the ground symbol next to the connector) somewhere on the front panel.
  • Page 80 To attach the ESD wrist strap to the system ground lug screw for the Cisco Nexus 5548 switch, you can follow the same procedure that is used for Cisco Nexus 5000 switch.
  • Page 81: Establishing The System Ground

    1 and 10 megohm (Mohm). Establishing the System Ground This section describes how to connect a system ground to the Cisco Nexus 5548P switch or or the Cisco Nexus 5000 Series switch. This system ground is also referred to as the network equipment building system (NEBS) ground.
  • Page 82: Grounding The Cisco Nexus 5548P Chassis

    Cisco Nexus Cisco Nexus 5548P switch is identical to that on the Cisco Nexus 5000 Series switch. For the procedure on how to ground the Cisco Nexus 5000 Series switch chassis, see page x-x. Note...
  • Page 83: Grounding The Cisco Nexus 5000 Series Switch Chassis

    Grounding the Cisco Nexus 5000 Series Switch Chassis The chassis has a grounding pad with two threaded M4 holes for attaching a grounding lug. shows the system ground location on the Cisco Nexus 5020 switch. It is identical for the Cisco Nexus 5010 switch.
  • Page 84 Step 3 Cisco Nexus 5000 Series Hardware Installation Guide 3-20 Chapter 3 Installing the Cisco Nexus 5500 Platform or 5000 Series Switch Location of System Ground on a Cisco Nexus 5000 Switch 4 Screws, M4, with square cone washers 5 NRTL listed grounding lug...
  • Page 85: Starting The Switch

    Do not connect the Ethernet port to the LAN until the initial switch configuration has been performed. Note For instructions on configuring the switch, see the Cisco Nexus 5000 Series CLI Configuration Guide. For instructions on connecting to the console port, see the page 4-2.
  • Page 86: Removing And Installing Components

    A setup utility automatically launches the first time you access the switch and guides you through the Note basic configuration. For instructions on how to configure the switch and check module connectivity, see the Cisco Nexus 5000 Series CLI Configuration Guide or the Cisco Nexus 5000 Series Fabric Manager Configuration Guide. Removing and Installing Components This section describes how to remove and install components for the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch.
  • Page 87: Removing And Installing Expansion Modules

    Chapter 3 Installing the Cisco Nexus 5500 Platform or 5000 Series Switch S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m...
  • Page 88: Installing An Expansion Module In The Cisco Nexus 5000 Series Chassis

    S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m Figure 3-11 Installing an Expansion Module in the Cisco Nexus 5000 Series Chassis To install an expansion module in the Cisco Nexus5000 Series chassis, follow these steps: Grasp the handle of the module and place your other hand under the module to support it.
  • Page 89 Chapter 3 Installing the Cisco Nexus 5500 Platform or 5000 Series Switch S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m...
  • Page 90: Removing An Expansion Module

    Removing a Power Supply If you are using the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch with one power Caution supply, removing the power supply will cause the switch to shut down. If you are using two power supplies and you remove one of them, the switch will continue to operate.
  • Page 91 Chapter 3 Installing the Cisco Nexus 5500 Platform or 5000 Series Switch S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m Install a blank power supply filler panel if the power supply bay is to remain empty.
  • Page 92: Installing A Power Supply

    S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m Installing a Power Supply To install a power supply Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch, follow these steps: Ensure that the system (earth) ground connection has been made.
  • Page 93: Installing A Fan Module

    Chapter 3 Installing the Cisco Nexus 5500 Platform or 5000 Series Switch S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m...
  • Page 94: Removing A Fan Module

    3-19shows a fan module partially installed in the Cisco Nexus 5010 switch. Figure 3-19 Listen for the fans if the switch is powered on. You should immediately hear them operating. If you do Step 3 not hear them, ensure that the fan module is inserted completely in the chassis and the faceplate is flush with the outside surface of the chassis.
  • Page 95: Removing The Cisco Nexus 5548P Switch Or The Cisco Nexus 5000 Series Switch

    To remove the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch from a rack, follow these steps:...
  • Page 96 Installing the Cisco Nexus 5500 Platform or 5000 Series Switch Repacking the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch for Return Shipment S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m...
  • Page 97: Connecting The Switch

    Connecting to the Ethernet Connector Port, page 4-3 • Connecting to an Ethernet Port, page 4-4 • Connecting to a Fibre Channel Port, page 4-7 • OL-15902-01 C H A P T E R Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 98: Chapter 4 Connecting The Switch

    Preparing for Network Connections When preparing your site for network connections to the Cisco Nexus 5500 Patform switch or Cisco Nexus 5000 Series switch, consider the following for each type of interface, and gather all the required equipment before connecting the ports: Cabling required for each interface type •...
  • Page 99: Connecting To The Ethernet Connector Port

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m You can use the console port to perform the following: Configure the Cisco Nexus 5500 Platform switch or Cisco Nexus 5000 Series switch from the CLI. •...
  • Page 100: Connecting To An Ethernet Port

    If you cannot install the cable into the transceiver, insert or leave the dust plug in the cable end Note of the transceiver. Cisco Nexus 5000 Series Hardware Installation Guide Chapter 4 4-5r Connecting the Switch...
  • Page 101: Removing An Sfp+ Transceiver

    Next, lower the bale clasp and pull the SFP+ transceiver straight out with a slight upward lifting force (see Figure 4-2 Alternate Removal Method for Bale Clasp SFP+ Transceivers OL-15902-01 Figure 4-2). Be careful not to damage the port cage during this process. Cisco Nexus 5000 Series Hardware Installation Guide Connecting to an Ethernet Port...
  • Page 102: Removing And Installing Cables Into Sfp+ Transceivers

    If the cable does not install easily, ensure that it is correctly positioned before continuing. Caution For instructions on verifying connectivity, see the Cisco Nexus 5000 Series CLI Configuration Guide. Removing a Cable from an SFP+ Transceiver When pulling a cable from a transceiver, grip the body of the connector. Do not pull on the jacket sleeve, Caution because this action can compromise the fiber-optic termination in the connector.
  • Page 103: Maintaining Sfp+ Transceivers And Cables

    • under a microscope to determine if damage has occurred. Connecting to a Fibre Channel Port This section applies to the Cisco Nexus 5500 Patform switches and the Cisco Nexus 5000 Series Note switches. You can use an SFP transceiver to connect to an Fibre Channel port.
  • Page 104: Removing And Installing Sfp Transceivers

    Record the cable and port connections for later reference. Press the release latch on the cable, grasp the connector near the connection point, and gently pull the connector from the transceiver. Cisco Nexus 5000 Series Hardware Installation Guide Chapter 4 Connecting the Switch...
  • Page 105 If another transceiver is not being installed, protect the optical cage by inserting a clean cover. Step 5 OL-15902-01 Connecting to a Fibre Channel Port Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 106: Removing And Installing Cables Into Sfp Transceivers

    (See Figure 4-4 Connecting the LC-Type Cable to a Fibre Channel Port If the cable does not install easily, ensure that it is correctly positioned before continuing. Caution Cisco Nexus 5000 Series Hardware Installation Guide 4-10 Figure 4-4). LC plug...
  • Page 107: Removing A Cable From An Sfp Transceiver

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m For instructions on verifying connectivity, see the appropriate Cisco Nexus 5000 Series CLI Configuration Guide..
  • Page 108 S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 109: Appendix

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Cabinet and Rack Installation This appendix provides the requirements for cabinet and rack installation for the Cisco 5500 Platform switch or the Cisco Nexus 5000 Series switch and includes the following sections: Cabinet and Rack Requirements, page •...
  • Page 110: General Requirements For Cabinets And Racks

    The width between the rack-mounting rails must be at least 17.75 inches (45.1 cm) if the rear of the • switch is not attached to the rack. For four-post EIA racks, this is the distance between the two front rails.
  • Page 111: Requirements Specific To Solid-Walled Cabinets

    56 fiber or copper cables through the rack. OL-15902-01 Cable Management Guidelines “This section includes the following topics:” section on “This section includes the following topics:” section on Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 112 S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 113: Appendix

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Technical Specifications This appendix describes the technical specifications for the Cisco Nexus 5500 Platform switch and the Cisco Nexus 5000 Series switch.
  • Page 114: Environmental Specifications

    Table B-4 Property Operating temperature Nonoperating (storage) temperature Humidity Altitude Table B-5 lists the environmental specifications for the Cisco Nexus 5000 Series switches. Table B-5 Property Operating temperature Nonoperating (storage) temperature Humidity Altitude Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 115: Expansion Module Specifications

    Weight Power Specifications This section describes the power specifications for the the Cisco Nexus 5548 switch, the Cisco Nexus 5020 switch, and the Cisco Nexus 5010 switch. This section includes the following topics: Specifications for the Cisco Nexus 5548 Power Supply, page B-3 •...
  • Page 116: Specifications For The Cisco Nexus 5010 Power Supply

    Table B-10 Description Rated power Input voltage Frequency Cisco Nexus 5000 Series Hardware Installation Guide Specifications for the Cisco Nexus 5020 750 W Power Supply (continued) Specification 100–120 V/200–240 V 9.2 A/4.5 A 50–60 Hz 2500 BTU/hr 1:1 (1200 W or 750 W) 1.57 in.
  • Page 117: Power Supply Led Indicators

    Power Supply LED Indicators Table B-11 lists the LED indicators for the LED on the front of the power supply for the Cisco Nexus 5500 Platform switches and the Cisco Nexus 5000 Series switches. Table B-11 Condition No AC power to the power supplies...
  • Page 118: Transceiver Specifications

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Transceiver Specifications Table B-12 lists the general specifications for the 10-Gigabit Ethernet SFP+ transceiver module for the Cisco Nexus 5500 Platform switches and the Cisco Nexus 5000 Series switches. Table B-12 Description Connector type...
  • Page 119: Environmental Conditions And Power Requirements Specification For Sfp

    NEBS Compliance and ETSI 300-019 Environmental Requirements The Cisco Nexus 5500 Platform switches and the Cisco Nexus 5000 Series switches meet the industry EMC, safety, and environmental standards described in Table 16...
  • Page 120: Gr-1089 Installation And Caution Instructions

    OSP cabling. The addition of primary protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring. The Cisco Nexus 5500 Platform switches and the Cisco Nexus 5000 Series switches have AC power • ports that are intended for deployments where an external Surge Protective Device (SPD) is utilized at the AC power service equipment (see definition in National Electric Code).
  • Page 121: Appendix

    • Accessory Kit for the Cisco Nexus 5548 Switch This section describes the accessory kit contents for the Cisco Nexus 5548 switch and describes how to attach a power cord to the switch. The Cisco Nexus 5548 switch accessory kit includes the following items: 2 slider rails •...
  • Page 122: Accessory Kit For The Cisco Nexus 5020 Switch

    S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Accessory Kit for the Cisco Nexus 5020 Switch This section describes the accessory kit contents for the Cisco Nexus 5020 switch and describes how to attach a power cord to the switch.
  • Page 123: Console Cable

    Additional parts can be ordered from your customer service representative. Note Console Cable This section applies to the Cisco Nexus 5548 switch, the Cisco Nexus 5020 switch, and the Cisco Nexus Note 5010 switch. The console cable has a RJ-45, RS-232 connector on one end and a DB9 connector on the other end. See Figure C-3.
  • Page 124: Cable Rj-45 Connector Pinouts

    RJ-45 connector on the console cable. Table C-1 Signal Name Console Port This section applies to the Cisco Nexus 5548 switch, the Cisco Nexus 5020 switch, and the Cisco Nexus Note 5010 switch. Cisco Nexus 5000 Series Hardware Installation Guide...
  • Page 125: Console Port Pinouts

    Table C-3 Signal Supported Power Cords and Plugs This section applies to the Cisco Nexus 5548 switch, the Cisco Nexus 5020 switch, and the Cisco Nexus Note 5010 switch. Each power supply has a separate power cord. Standard power cords or jumper power cords are available for connection to a power distribution unit having IEC 60320 C19 outlet receptacles.
  • Page 126: Power Cords

    The standard power cords have an IEC C13 connector on the end that plugs into the switch. The optional jumper power cords have an IEC C13 connector on the end that plugs into the switch, and an IEC C14 connector on the end that plugs into an IEC C13 outlet receptacle.
  • Page 127 Power Cords for the Cisco Nexus 5020 Switch (continued) Length Feet SFS-250V-10A-AR 2500 mm Cordset rating: 10 A, 250/500 V MAX Length: 8.2 ft Cisco Nexus 5000 Series Hardware Installation Guide Supported Power Cords and Plugs Power Cord Reference Meters Illustration Figure C-12...
  • Page 128 Figure C-5 A.S. 3112-2000) Figure C-6 Plug: EL 218 (CCEE GB2009) Figure C-7 Plug: M2511 Cisco Nexus 5000 Series Hardware Installation Guide CAB-9K10A-AU Cordset rating: 10 A, 250 V/500V Length: 2500mm Plug: EL 206 SFS-250V-10A-CN Cordset rating 10A, 250V (2500 mm)
  • Page 129 Cordset rating 10A, 250V/500V MAX (2500 mm) CAB-9K10A-IT Cordset rating: 10 A, 250 V Length: 8 ft 2 in. (2.5 m) I/3G Cisco Nexus 5000 Series Hardware Installation Guide Supported Power Cords and Plugs Connector: EL 701 Connector: EL 701B...
  • Page 130 (BS 1363A) 13 AMP fuse Figure C-12 (BS 1363A) 13 AMP fuse Figure C-13 Plug: EL312MoldedTwistlock (NEMA L6-20) Figure C-14 Cisco Nexus 5000 Series Hardware Installation Guide C-10 CAB-9K10A-SW Cordset rating: 10 A, 250 V/500 V MAX Length: 2500mm Plug: EL 210 CAB-9K10A-UK...
  • Page 131 Figure C-16 Plug: SS10A Figure C-17 OL-15902-01 CAB-9K12A-NA Cordset rating 13A, 125V (8.2 feet) (2.5m) Plug: CAB-C13-CBN Cordset rating 10A, 250V (686mm) CAB-IND-10A Cisco Nexus 5000 Series Hardware Installation Guide Supported Power Cords and Plugs Connector: IEC60320/C15 Connector: HS10S C-11...
  • Page 132: Jumper Power Cord

    Cisco Nexus 5020 switch. The plug plugs into the Cisco Nexus 5020 switch power supply, while the connector plugs into the receptacle of a power distribution unit for a cabinet.
  • Page 133: Appendix

    Contact and Site Information, page D-3 • Chassis and Module Information, page D-4 • For information about how to query the switch for configuration information, see the Cisco Nexus 5000 Note Switch Configuration Guide. Site Preparation Checklist Planning the location and layout of your equipment rack or wiring closet is essential for successful switch operation, ventilation, and accessibility.
  • Page 134 Site wiring • • 1. Verify that the power supply installed in the chassis has a dedicated AC source circuit. 2. UPS = uninterruptible power supply. Cisco Nexus 5000 Series Hardware Installation Guide Verified By for power failures evaluation: levels...
  • Page 135: Contact And Site Information

    Data center location Floor location Address (line 1) Address (line 2) City State Zip code Country OL-15902-01 (Table D-2) to record contact and site information. Contact and Site Information Cisco Nexus 5000 Series Hardware Installation Guide Contact and Site Information...
  • Page 136: Chassis And Module Information

    Slot Module Type 1 Supervisor 2 The supervisor module and the interface module are not removable. Note Cisco Nexus 5000 Series Hardware Installation Guide (Table D-3 Table D-4) to record information about the chassis and Network-Related Information Module Information Module Serial Number...
  • Page 137: Appendix

    Troubleshooting Hardware Components This appendix describes how to identify and resolve problems that might occur with the hardware components of the Cisco Nexus 5500 Platform switch or the Cisco Nexus 5000 Series switch. It includes the following sections: Overview, page E-1 •...
  • Page 138: Switch Hardware Best Practices

    Never use the init system CLI command unless you understand that you will lose the running and • startup configuration as well as the files stored on bootflash:. Keep backup copies of the running kickstart and the system images on CompactFlash. • Cisco Nexus 5000 Series Hardware Installation Guide Appendix E Troubleshooting Hardware Components OL-15902-01...
  • Page 139 (procedure) pinouts contact and site information records worksheet 3-6, 3-8, 3-11 3-31 dimensions chassis Cisco 5000 Series Hardware Installation Guide 3-17 2-1, 2-18 1-3, 2-2, 2-18, B-1, B-2 2-5, 2-22 1-10, 2-12, 2-29 1-3, 2-1, 2-18 1-4, 2-2, 2-19 3-19...
  • Page 140 2-1, 2-18 fiber optic cables maintaining 4-11 Fibre Channel over Ethernet protocol. See FCoE protocol Fibre Channel plus Ethernet expansion module description Cisco 5000 Series Hardware Installation Guide IN-2 port grouping port numbering (figure) 2-6, 2-10 Fibre Channel ports connecting...
  • Page 141 SFPs. See SFP transceivers troubleshooting best practices 4-11 1-12, 2-16, 2-31 B-1, B-2 B-3, B-4 Cisco 5000 Series Hardware Installation Guide Index IN-3...
  • Page 142 S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m Cisco 5000 Series Hardware Installation Guide...

This manual is also suitable for:

Nexus 5500Nexus 5000 series

Table of Contents

Save PDF