hit counter script

Product Specification - Hitachi S1 Series Basic Manual

Table of Contents

Advertisement

S1 series standard inverter
R
S
T
PE
R
S
T
PE
Note:
1. 132kW and above inverters can be connected to external DC reactors. Before connection, it is
required to take off the copper bar between P1 and (+). 132kW and above inverters can be
connected to external brake unit. DC reactors and brake units are optional parts.
2. 18.5kW–110kW inverters are equipped with built-in DC reactor.
3. 37kW and below models carry built-in brake units, 45kW–55kW supports built-in brake unit.
75kW–400kW supports external brake unit. The models that carry built-in brake unit can also be
connected to external brake resistor. The brake resistor is optional part.

3.3 Product specification

Function description
Input voltage (V)
Power input
Input current (A)
Input frequency (Hz)
Power
Output voltage (V)
output
Output current (A)
(+)
DC reactor
(-)
Fig 3.4 400V (18.5kW–110kW) main circuit diagram
(+)
DC reactor
P1
Fig 3.5 400V (132kW and above) main circuit diagram
AC 1PH 220V (-15%)–240V (+10%) rated voltage: 230V
AC 3PH 380V (-15%)–440V (+10%) rated voltage: 400V
Refer to Rated value
50Hz or 60Hz, allowable range: 47–63Hz
0–input voltage
Refer to Rated value
PB
(-)
Specification
-9-
U
V
W
PE
U
V
W
PE