hit counter script
Dell S5000 Series Hardware Description Manual

Dell S5000 Series Hardware Description Manual

Servers for sap hana
Hide thumbs Also See for S5000 Series:

Advertisement

Quick Links

Dell S5000 Series Servers for SAP HANA
Description Guide
Regulatory Model: M3S2G8, M3UX16
September 2022
Rev. A01

Advertisement

Table of Contents
loading

Summary of Contents for Dell S5000 Series

  • Page 1 Dell S5000 Series Servers for SAP HANA Description Guide Regulatory Model: M3S2G8, M3UX16 September 2022 Rev. A01...
  • Page 2 Copyright © 2022 Dell Inc. or its subsidiaries. All rights reserved. Dell Technologies, Dell, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
  • Page 3 Intended audience This document is intended for use by administrators and operators. Related documents For the most recent product information, documentation, firmware updates, software fixes, and service offers, see the Dell Technologies Support Site.
  • Page 5: Table Of Contents

    ..........Chapter 2. Dell S5000 Series Servers Overview ....... .
  • Page 6 Chapter 5. UBox Components ........... 5.1.
  • Page 7: Regulatory Declarations And Disclaimers

    Regulatory Declarations and Disclaimers Safety Compliance Statement This product is in compliance with the following directives: European Union (EU) Certification Low voltage directive 2014/35/EU: standard EN 60950-1 UL/CSA Certification UL 60950 (USA) CSA 60950 (Canada) International Certification (Standard memory servers only) Standard IEC 60950-1 Electromagnetic Compatibility Statement This product is in compliance with the protection requirements of the following...
  • Page 8: Iecs-03 Certification (Canada

    Pursuant to Part 15.21 of the FCC Rules, any changes or modifications to this equipment not expressly approved by the manufacturer may cause harmful interference and void the FCC authorization to operate this equipment. An FCC regulatory label is affixed to the equipment. IECS-03 Certification (CANADA) Canadian Compliance Statement (Industry Canada) This Class A digital apparatus meets all requirements of the Canadian...
  • Page 9: Safety Notices

    Safety Notices Important Read the safety notices before undertaking any procedures described in the documentation. All safety notices used in the documentation are listed in the Multilingual Safety Notices Guide and are classified by severity: D0xx DANGER D0xx A Danger notice indicates the presence of a hazard that has the potential of causing death or serious personal injury.
  • Page 11: Chapter 1. Related Publications

    • Dell S5000 Series Servers for SAP HANA Rack Cabinet Prerequisites gives the prerequisites to install a Dell S5000 Series server in a rack cabinet. Installation • Dell S5000 Series Servers for SAP HANA R@ck'n Roll 1200 Installation and Service Guide explains how to install and service the cabinets.
  • Page 12 Reference Guide describes the Hardware Management CLI (Command Line Interface) for the Dell S5000 Series Servers for SAP HANA. This guide is intended for use by system administrators and operators in charge of managing systems locally and remotely and of writing server management batch scripts.
  • Page 13: Chapter 2. Dell S5000 Series Servers Overview

    Chapter 2. Dell S5000 Series Servers Overview 2.1. Overview The Dell S5000 Series Servers for SAP HANA are designed to be modular, easy to maintain and to increase density and maximize memory capacity. ® ® ® They exploit the Intel...
  • Page 14: Dell S5000 Series Servers

    2.2. Dell S5000 Series Servers 2.2.1. S5408 Server The S5408 server is composed of: • Four modules • One 4-module connecting box Rear view Mark Label 4-module connecting box Module 0 Module 1 Module 2 Module 3 Note If the server is not fully populated with four modules, a filler bezel can be inserted into the empty space.
  • Page 15: S5416 Server

    S5416 Server 2.2.2.1. Overview The S5416 server is composed of: • Two S5408 server assemblies (A) • The 8-module connecting box at the rear (B) • The UBox at the front (C) Rear view Chapter 2. Dell S5000 Series Servers Overview...
  • Page 16 Exploded view Front view Description Guide...
  • Page 17 2.2.2.2. Modules Numbering Rear view Mark Description Module 0 Module 1 Module 2 Module 3 Module 4 Module 5 Module 6 Module 7 Chapter 2. Dell S5000 Series Servers Overview...
  • Page 18: Module

    2.3. Module 2.3.1. Module Overview The module consists of the bezel and the main box at the front, the Power Supply Units (PSUs), the PCIe slots and the Intermodule connecting box at the rear. All these components are included in the compute box. Mark Description Bezel...
  • Page 19: Main Box Overview

    Filler Bezel If the server is not fully populated with modules, a filler bezel is inserted into the empty space. It is attached to the front of the server by two captive screws. Chapter 2. Dell S5000 Series Servers Overview...
  • Page 21: Chapter 3. Rear Component Slots

    Chapter 3. Rear Component Slots 3.1. S5408 Server Rear view Mark Description Identification drawer Power Supply Unit (PSU) Two PCIe x8 blades or one PCIe x16 blade Phy Ethernet Board (PEB) or Phy Ethernet Board SFP+ (PEBS) PCIe x8 blade dedicated for RAID/SAS controller 4-module connecting box sWitch Ethernet One Gigabit (WEO) Chapter 3.
  • Page 22: Power Supply Units (Psus)

    3.2. Power Supply Units (PSUs) Each module is equipped with two PSU (1+1 redundancy). Rear view Mark Description PSU 1 PSU 0 Description Guide...
  • Page 23: Chapter 4. Compute Unit Components

    Chapter 4. Compute Unit Components 4.1. Components Front view Mark Description Quantity CPU Purley Board (CPB) Motherboard Front Disk Blades (FDB) Management Board Left Side (MLB) Management Board Right Side (MRB) Chapter 4. Compute Unit Components...
  • Page 24: Cpu Purley Board (Cpb) Motherboard

    4.2. CPU Purley Board (CPB) Motherboard Top view Mark Description Quantity Memory modules Processor Assembly (CPU) PCIe slots UPI slot PCIe connectors FDB Connectors Description Guide...
  • Page 25: Processor Assembly (Cpu)

    4.3. Processor Assembly (CPU) Top view Mark Description CPU 0 CPU 1 Chapter 4. Compute Unit Components...
  • Page 26: Memory Modules

    4.4. Memory Modules Description Guide...
  • Page 27 Board Board Locator for BIOS setup memory Mark Channel DIMM BIOS locator slot dmidecode topology page setting J5C3 CHC-0 M0 CPU0 CH2 DIMM0 Socket0.ChC.Dimm0 sck0ch2 J5C4 CHC-1 M0 CPU0 CH2 DIMM1 Socket0.ChC.Dimm1 J5C5 CHB-0 M0 CPU0 CH1 DIMM0 Socket0.ChB.Dimm0 sck0ch1 J6C1 CHB-1 M0 CPU0 CH1 DIMM1 Socket0.ChB.Dimm1...
  • Page 28: Pcie Slots

    4.5. PCIe Slots PCIe Slot Numbering Top view PCIe slot Type PCIe x8 blade PCIex16 blade PCIe x8 blade PCIe x8 blade PCIex16 blade PCIe x8 blade PCIe x8 blade dedicated to RAID/SAS controller Internal PCIe x16 connector dedicated to GPU card, SAS card or NVME adapter Internal PCIe x16 connector dedicated to GPU card Description Guide...
  • Page 29 BIOS Settings Module Slot Socket PCIe Port Number Cli Parameter Port 1C PCI.PciePortDisable_1 Port 1A PCI.PciePortDisable_3 Port 2A PCI.PciePortDisable_28 Port 2C PCI.PciePortDisable_26 Port 1A PCI.PciePortDisable_22 Port 3A PCI.PciePortDisable_30 Port 3A PCI.PciePortDisable_9 Port 1C PCI.PciePortDisable_43 Port 1A PCI.PciePortDisable_45 Port 2A PCI.PciePortDisable_70 Port 2C PCI.PciePortDisable_68 Port 1A...
  • Page 30: Front Disk Blades (Fdb)

    4.6. Front Disk Blades (FDB) 4.6.1. FDB Numbering Front view Mark Description FDB 0 FDB 1 FDB 2 FDB 3 Description Guide...
  • Page 31: Fdb Description

    4.6.2. FDB Description Mark Description Quantity SAS (or SATA for the operating system) disks 2 Fan boxes 4.6.3. FDB Disks FDB disks identification Mark Description Top disk Bottom disk Chapter 4. Compute Unit Components...
  • Page 32 FDB Disks Numbering Front view Mark Description Disk 1 Disk 2 Disk 3 Disk 4 Disk 5 Disk 6 Disk 7 Disk 8 FDB and Controller Physical Mapping Physical mapping is identical for LSI SAS 9300-8i and LSI MegaRaid SAS 9361-8i cards.
  • Page 33 FDB and RAID Controller Physical Mapping The table below describes the physical mapping for internal SATA RAID without additional adapter. Mark Disk Type Mapping None None None None None None None None SATA SATA Port 2 None None SATA SATA Port 3 None None Chapter 4.
  • Page 34: Fdb Fan Boxes

    4.6.4. FDB Fan Boxes Top view Mark Description Fan box0 Fan box1 4-12 Description Guide...
  • Page 35: Ubox Components

    Chapter 5. UBox Components This chapter applies only to the S5416 server. 5.1. Components Front view Exploded view Mark Description Quantity LMB module CLKB module SCI module UNB fan module 12 or 24 UNB module 2 or 4 Chapter 5. UBox Components...
  • Page 36 Rear view Mark Description Quantity UBox PSU Up to 4 Description Guide...
  • Page 37: Numbering

    5.2. Numbering 5.2.1. UNB Module Numbering Front view Mark Description UNB module 0 UNB module 1 UNB module 2 UNB module 3 Chapter 5. UBox Components...
  • Page 38: Unb Memory Module Numbering

    5.2.2. UNB Memory Module Numbering Top view Mark Description UNC 0 - CH 1 UNC 0 - CH 0 UNC 1 - CH 1 UNC 1 - CH 0 UNC 2 - CH 1 UNC 2 - CH 0 UNC 3 - CH 1 UNC 3 - CH 0 Description Guide...
  • Page 39: Sci Module Numbering

    5.2.3. SCI Module Numbering Front view Mark Description SCI module 0 SCI module 1 Chapter 5. UBox Components...
  • Page 40: Clkb Module Numbering

    5.2.4. CLKB Module Numbering Front view Mark Description CLKB module 0 CLKB module 1 5.2.5. UNB Fan Module Numbering UNB fan modules are numbered from 0 to 5 for each UNB module. The UNB fan modules for UNB module 1 are shown in the image below. Front view Description Guide...
  • Page 41: Ubox Psu Numbering

    5.2.6. UBox PSU Numbering Rear view Mark Description UBox PSU 0 UBox PSU 1 UBox PSU 2 UBox PSU 3 There are up to four PSUs installed in a UBox, according to the voltage range and the UBox model. System Voltage Population rule Redundancy...
  • Page 43: Leds, Buttons And Ports

    Chapter 6. LEDs, Buttons and Ports 6.1. Front LEDs and Buttons 6.1.1. Compute Unit LEDs The system state is indicated by the green power LED blinking intervals. For example, as shown in the table below, the standby system state is indicated when the power LED blinks every four seconds.
  • Page 44: Hitdp Unit Leds

    6.1.2. HITDP Unit LEDs Front view Mark Color Description Component SAS fan module 1 SAS fan module 2 SAS fan box failure SAS fan module 3 Description Guide...
  • Page 45: Ubox Leds

    6.1.3. UBox LEDs This section applies to the S5416 server only. 6.1.3.1. CLKB module LEDs Front view Mark Color Description Amber Power Blue Identification Chapter 6. LEDs, Buttons and Ports...
  • Page 46 6.1.3.2. UNB fan module LEDs Front view Mark Color Description Fault 6.1.3.3. UNB module LEDs Front view Mark Color Description Amber Power Blue Identification Description Guide...
  • Page 47 6.1.3.4. LMB module LEDs Mark Color Description Amber Power Blue Identification Firmware recovery Green LMB module ethernet link activity Green LMB module Peer ethernet link activity Green Module 0 ethernet link activity Green Module 1 ethernet link activity Green Module 2 ethernet link activity Green Module 3 ethernet link activity Green...
  • Page 48: Buttons

    6.1.4. Buttons 6.1.4.1. Module Buttons Front view Mark Description Component Power-on Management Board Right Side (MRB) Module identification Management Board Right Side (MRB) BMC reset Management Board Right Side (MRB) 6.1.4.2. UBox Buttons This section applies to the S5416 server only. Front view Mark Button...
  • Page 49: Rear Leds And Buttons

    6.2. Rear LEDs and Buttons 6.2.1. LEDs Rear view Case of a PEB Mark Color Description Component Attention - PCIe blade Amber failure PCIe x8 blade or PCIe x16 blade Power - PCIe blade Green successfully initialized Power Supply Unit (PSU) powered on Solid green Blinking green...
  • Page 50 Mark Color Description Component PEB flash firmware is Blinking red updated System powered on in Phy Ethernet Board normal mode (PEB) Link 1 Gb/s Ethernet Yellow Link 10 Gb/s Ethernet Green Blinking Yellow Ethernet link activity No Ethernet link activity Green Activity sWitch Ethernet One...
  • Page 51 Case of a PEBS Mark Color Description Component Attention - PCIe blade Amber failure PCIe x8 blade or PCIe x16 blade Power - PCIe blade Green successfully initialized Power Supply Unit (PSU) powered on Solid green Blinking green Power Supply Unit Power Supply Unit (PSU) on stand-by (PSU)
  • Page 52 Mark Color Description Component Blinking blue Identification System powered on in firmware recovery mode System powered on in normal mode Orange Link 1 Gb/s Ethernet Blinking yellow Ethernet link activity Phy Ethernet Board SFP+ (PEBS) No Ethernet link activity Link 1 Gb/s Ethernet Yellow Link 10 Gb/s Ethernet Green...
  • Page 53: Buttons

    6.2.2. Buttons Rear view Case of a PEB Case of a PEBS Mark Button Component Attention button PCIe x8 blade or PCIe x16 blade Firmware Phy Ethernet Board (PEB) or Phy Ethernet recovery button Board SFP+ (PEBS) Chapter 6. LEDs, Buttons and Ports 6-11...
  • Page 54: Ports

    6.3. Ports Front view Mark Type Component USB ports Management Board Left Side (MLB) Micro USB port Management Board Left Side (MLB) VGA port Management Board Right Side (MRB) Rear view Case of a PEB Mark Type Component RJ45 - 10 Gb/s / 0, 1, 2, 3 Phy Ethernet Board (PEB) 1 Gb/s Ethernet...
  • Page 55: Appendix A. Technical Description

    Appendix A. Technical Description A.1. General Technical Specifications Operating Limits Ambient air temperature +10°C to + 35°C Gradient 20°C / hour Relative humidity (non condensing) 20% to 60% Gradient 5%/hour Pressure / Elevation Sea level < 2500m Non-Operating Limits Ambient air temperature <5°C and >50°C Relative humidity (non condensing) <5% and >95% (Gradient 30%/h)
  • Page 56: Module Technical Specifications

    A.3. Module Technical Specifications Power Cables and PDU AC (32A) 1 per PDU PDU connector type C13-C14, 10-16A PDU cable type C13-C14, 10-16A Electrical Specifications Each module is equipped with 2 PSU with 2 C13-C14 cable connections. Rated Current 7.7 A Power consumption Typical: <...
  • Page 57: Server Technical Description

    A.5. Server Technical Description Processors • S5408 server: 8 processors Number • S5416 server: 16 processors ® ® Type Intel Xeon Scalable processor Architecture for S5408 servers Intel ® C627 Chipset Chipset • UPI protocol between modules • UPI protocol between CPU sockets Ultra Path Maximum Ultra Path Interconnect at 10.4 GT/s Interconnect...
  • Page 59: Acronyms

    Acronyms ACPI Advanced Configuration and Power Interface ADDDC Adaptive Double Device Data Correction BIOS Basic Input / Output System Baseboard Management Controller Command Line Interface CPU Purley Board Motherboard CPLD Complex Programmable Logic Device Central Processing Unit Customer Replaceable Unit Certificate Signing Request DDR4 Double Date Rate fourth generation...
  • Page 60 Extensible Firmware Interface Embedded Management Module Electrostatic Discharge Ethernet Switch Module Front Disk Blade FPGA Field Programmable Gate Array FQDN Fully Qualified Domain Name Graphical Processing Unit Hard Disk Drive Intra Integrated Circuit IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface Java Runtime Environment Kilovolt-Ampere Keyboard Video Mouse...
  • Page 61 Local Area Network Liquid Crystal Display Local Control Panel LDAP Lightweight Directory Access Protocol Light Emitting Diode Local Management Board Local Management Controller Media Access Control Management Board Left Side Management Board Right Side Management Interface Base Management Switch Module NVMe disk Backplane Board NEMA National Electrical Manufacturers Association...
  • Page 62 PCIe PCI Express Power Distribution Board Platform Controller Hub Power Distribution Unit PHY Ethernet Board PEBS PHY Ethernet Board SFP+ Platform Event Filtering Platform Event Trap PHP: Hypertext Preprocessor PIROM Processor Information ROM Power Supply Unit RADIUS Remote Authentication Dial-In User Service. RAID Random Array of Independent Disks Reliability, Availability, Serviceability...
  • Page 63 SATA Serial ATA SAS disk Backplane Board Solid State Drive SDDC Single Device Data Correction Sensor Data Repository System Event Log Server Hardware Console SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol Serial Over LAN Secured Shell Secure Socket Layer TELNET TELecommunication NETwork UNC Board...
  • Page 64 VLAN Virtual Local Area Network Virtual Machine sWitch Ethernet One Gigabit External Node Controller No entries. No entries. a‐6 Description Guide...

This manual is also suitable for:

M3s2g8M3ux16

Table of Contents