Codepads on Solution 2000/3000
Codepads
The Solution 2000/3000 control panels support two types of codepads: an Alphanumeric LCD
codepad (IUI-SOL-TEXT) and an Icon LCD codepad (IUI-SOL-ICON).
If multiple codepads reside on the same system, each codepad must have a unique address. The
Solution 2000/3000 control panels support up to 4 codepads, addresses 01-04. DIP switch address
settings greater than 4 prevent the codepad from processing messages recieved on the SDI2 bus and
the option bus. Any change to the DIP switch requires a power cycle or software reboot of the module
for the new external address to be read.
DIP Switch
Codepad
Address
1
On
2
Off
3
On
4
Off
Table 4.1 Codepad DIP Switch address settings
1
2
Off
Off
On
Off
On
Off
Off
On
Installation
Set the address switches for the proper
address, mount the mounting plate, wire
to the control panel, attach the codepad to
the mounting plate.
NOTICE!
Do not remove the spring from the tamper
switch on the IUI-SOL-ICON. Removing
the spring will cause a Codepad Tamper
Trouble and a report will be sent if
configured to do so.
Set the address
The IUI-SOL-TEXT and IUI-SOL-ICON
have 6 DIP switches that support SDI2
addresses 01 to 16. DIP switches
determine the address for the codepad.
The control panel uses address for
communications. Use a ballpoint pen to set
DIP Switch Number
3
4
Off
Off
Off
Off
Off
Off
Off
Off
5
6
On
On
On
On