hit counter script
Download Print this page
Sealey STW901 Quick Start Manual

Sealey STW901 Quick Start Manual

Sq drive torque wrench micrometer style - calibrated series

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
instructions
1. SAFETY
Ensure all workshop safety rules, regulations, and conditions are complied with when using torque wrench.
9
Maintain the wrench in good condition and replace any damaged or worn parts. Use genuine parts only. Non-authorised parts may be
9
dangerous and will invalidate the warranty.
The wrench is a precision tool, DO NOT abuse it.
9
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
WARNING! DO NOT use the wrench if damaged or thought to be faulty. (Contact Service Agent).
DO NOT drop or throw the wrench.
8
DO NOT use wrench unless you have been instructed in its use by a qualified person.
8
DO NOT use any cleaner which might affect the high pressure grease with which the wrench is packed.
8
After use adjust to lowest torque setting (but not below),clean and store in a safe, dry, childproof location.
9
2. INTRODUCTION
Flip reverse Chrome Vanadium steel ratchet head with smooth action mechanism. Scales graduated in both Nm and lb.ft. Calibration
tolerance in accordance with BS EN ISO 6789-1:2017. Wrenches are individually tested to standards with ±4% accuracy and each
wrench is issued with an individually numbered test certificate. Aluminium knurled handle for comfort and control. Supplied in EVA
tray.
3. SPECIFICATION
Model
STW901
Drive
1/4"
Length
245mm
Range
5-25Nm
4. OPERATION
4.1.
PREPARING TO SET TORQUE (fig.1)
4.1.1.
Release torque adjuster by sliding the collar backwards. Set torque (see 4.2) and then lock in place by sliding the collar forwards.
fig.1
© Jack Sealey Limited
SQ DRIVE TORQUE WRENCH MICROMETER
STYLE - CALIBRATED SERIES
MODEL NO:
STW902
STW903
STW904
3/8"
3/8"
1/2"
245mm
420mm
520mm
5-25Nm
20-120Nm
40-220Nm
Original Language Version
STW900 SERIES
STW905
STW906
1/2"
3/4"
575mm
1050mm
60-330Nm
100-600Nm 200-800Nm
STW900 SERIES
STW907
3/4"
1210mm
Issue 1
20/05/20

Advertisement

loading

Summary of Contents for Sealey STW901

  • Page 1 STW900 SERIES MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Environment Protection

    This calibration check should also be carried out if the torque tool has been subjected to an impact, has been misused, or the readings are suspect. Jack Sealey Ltd have up-to-date calibration checking equipment, certified to international standards, to carry out this service.
  • Page 3 This Sealey Declaration of Conformance is issued at the time of manufacture and its validity is open ended until the torque tool is used for the first time. Unless otherwise stipulated, a period of 12 months, or 5,000 cycles, whichever occurs first, may be taken as default values for the interval between calibration checks.
  • Page 4 This Sealey Declaration of Conformance is issued at the time of manufacture and its validity is open ended until the torque tool is used for the first time. Unless otherwise stipulated, a period of 12 months, or 5,000 cycles, whichever occurs first, may be taken as default values for the interval between calibration checks.
  • Page 5 This Sealey Declaration of Conformance is issued at the time of manufacture and its validity is open ended until the torque tool is used for the first time. Unless otherwise stipulated, a period of 12 months, or 5,000 cycles, whichever occurs first, may be taken as default values for the interval between calibration checks.

This manual is also suitable for:

Stw900 seriesStw902Stw903Stw904Stw905Stw906 ... Show all