Page 1
Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide First Published: 2022-09-15 Last Modified: 2023-03-02 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
Page 2
Any products and features described herein as in development or available at a future date remain in varying stages of development and will be offered on a when-and if-available basis. Any such product or feature roadmaps are subject to change at the sole discretion of Cisco and Cisco will have no liability for delay in the delivery or failure to deliver any products or feature roadmap items that may be set forth in this document.
Connecting to a Console Connecting the Management Interface Connecting Interface Ports to Other Devices Installing SFP+ and SFP Transceivers Installing QSFP+ Transceivers Installing SFP+ and SFP Optical Cables Maintaining Transceivers and Optical Cables Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 4
Switch and Module Weights 2000-W AC Power Supply Specifications AC Power Cable Specifications A P P E N D I X C LEDs CPU Card LEDs LEM LEDs Fan LEDs Power Supply LEDs Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 5
Contents A P P E N D I X D Spare Parts Table Spares Support Table Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Overview of the Cisco Nexus 9408 Switch The Cisco Nexus 9408 (N9K-C9408) is a 4 rack unit (RU) 8-slot modular chassis switch, which is configurable with up to 128 200-Gigabit QSFP56 (256 100-Gigabit by breakout) ports or 64 400-Gigabit ports. This switch supports port-side intake airflow.
Page 8
The following figure shows the port-side chassis features that you use when installing the chassis or replacing its modules. Management port (RJ45) GPS 10 MHz Supervisor module (N9K-C9408-SUP-A) GPS 1PPS ToD (RF-45) SYNC, TIMING, GPS, BCN, STS, and ENV, LEDs Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 9
Careful when using the USB port. This component is sensitive to movement and if bumped, may cause file corruption. The following figure shows the side chassis features that you use when installing the chassis. Grounding pad Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 10
Overview Overview of the Cisco Nexus 9408 Switch Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
To prevent contaminant buildup and increased internal chassis temperatures, make sure that the operating environment is as clean as possible and free of dust and other contaminants. Do not permit smoking, food, or drinks near the switch. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 12
Preparing the Site Dust and Contaminants Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Starting the Switch, on page 20 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
Page 14
When installing the product, use the provided or designated connection cables/power cables/AC adapters. Warning Statement 1017 Restricted Area This unit is intended for installation in restricted access areas. Only skilled, instructed, or qualified personnel can access a restricted access area. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 15
Warning Statement 1022 Disconnect Device To reduce risk of electric shock and fire, a readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 16
Statement 164 Lifting Requirement 2 people are required to lift the heavy parts of the product. To prevent injury, keep your back straight and lift with your legs, not your back. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
• Site power meets the switch requirements. If you are using n+n redundancy, you must have two power sources within reach of the switch when it is installed in the cabinet or rack. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 18
Caution Avoid UPS types that use ferroresonant technology. These UPS types can become unstable with systems such as the Cisco Nexus switches. These switches can have substantial current draw fluctuations because of fluctuating data traffic patterns. Ensure that circuits are sized according to local and national codes. For North America, the power supply requires a 15-A or 20-A circuit.
• Port-side exhaust airflow direction indicated with blue coloring Installing the Chassis in a Four-Post Rack This section describes the installation of the Cisco Nexus 9408 platform switch, into a four-post rack, using the N9K-C9400-RMK rack-mount kit. Before moving or lifting the chassis, follow these guidelines:...
Page 20
• If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Step 1 Attach two front-mount brackets to the sides of the chassis as follows: Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 21
Align the bottom-support rails so that they form a shelf for the chassis. The bottom-support rails are not interchangeable. Use the one marked with [R] for the right, and with [L] Note for the left side of the rack. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 22
Position an expanding set of bottom-support brackets on the rack with each end touching a vertical mounting rail on the front and rear of the rack as shown in the following figure. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 23
Slide the power supply end of the chassis onto the installed bottom-support rails as shown in the following figure. Note When sliding the chassis onto the bottom-support rails, proceed slowly and cautiously so that you don’t damage the switch or support rails. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
If the rack requires another type of screw, use the appropriate torque setting for that type of screw. Grounding the Chassis The switch chassis is automatically grounded when you properly install the switch in a grounded rack with metal-to-metal connections between the switch and rack. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 25
(see Callout 2 in the following figure). Verify that the ground wire is securely attached to the grounding lug by attempting to pull the wire out of the crimped lug. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
4 power supplies, there must be a blank module (NXA-PS-BLANK) in the open power supply slot to maintain the designed airflow. Step 1 If the switch has AC power supplies, connect those power supplies to an AC power source as follows: Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 27
If not green, try removing the module part way from its slot and reinstalling it. • System Status LED—lit and green (if this LED is orange or red, then one or more environmental monitors is reporting a problem.) • Link LEDs for the Ethernet connector—Off Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 28
Installing the Chassis Starting the Switch Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
The console port on the switch is an RS-232 port with an RJ-45 interface. This is an asynchronous (async) serial port; any device connected to this port must be capable of asynchronous transmission. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
After you perform the initial configuration for the switch and create a management connection, you are ready to connect the interface ports on the switch to other devices. Depending on the types of interface ports on the Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Note If you cannot install the cable into the transceiver, insert or leave the dust plug in the cable end of the transceiver. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Align the QSFP+ transceiver in front of the module's transceiver socket opening and carefully slide the QSFP+ transceiver into the socket until the transceiver makes contact with the socket electrical connector. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
If you cannot install the cable into the transceiver, insert or leave the dust plug in the cable end of the transceiver. For instructions on verifying connectivity, see the appropriate Cisco Nexus Series configuration guide. Maintaining Transceivers and Optical Cables Transceivers and fiber-optic cables must be kept clean and dust free to maintain high signal accuracy and prevent damage to the connectors.
Page 34
Connecting the Switch to the Network Maintaining Transceivers and Optical Cables Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Attach an ESD wrist strap or other ESD device to your body and an earth ground to prevent ESD damage. You can attach the ESD device to any earth ground or grounded object, such as a grounded rack or ground connection on a chassis. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Remove the power supply as follows: a) Pull the power cord out from the power receptacle on the power supply to be removed and verify that the OK LED turns off. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Warning Statement 1051 Laser Radiation Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 38
Rotate the latch away from the module to disengage from the chassis as shown in the following figure. d) Holding the latch release lever handle, pull the module out of the chassis as shown in the following figure. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 39
Align the module with the open slot and gently slide the module into the slot until the lever's clamp engages with the chassis. Then rotate the lever up and toward the chassis until it clicks into the fully closed position . d) Tighten the module thumb-screws. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
LEM MIFPGA Warning Statement 1034 Backplane Voltage Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 41
Rotate the latch away from the module to disengage from the chassis as shown in the following figure. d) Holding the latch release lever handle, pull the module out of the chassis as shown in the following figure. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Attach each interface cable to the appropriate port on the module. Use the label on each cable to determine to which port each cable attaches. Replacing a Switch Card The Switch Card is hot-swappable. It is not necessary to shut down the switch before replacing the module. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 43
Push the lever button (2) to release the lever, as shown in the following figure. c) Disengage the lever (2) by pulling it out and away from the chassis, as shown in the following figure. d) Carefully remove the module. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 44
Align the module with the open slot and gently slide the module into the slot until the lever's clamp touches the chassis. Then engage the levers by pushing them toward the chassis until it clicks into place, reaching the fully closed position.. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 45
Replacing Modules Replacing a Switch Card d) Tightening the thumb screws. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 48
LEM-Module type is : 16x200G Ethernet Module 0 submodules are present Model number is N9K-X9400-16W H/W version is 0.3 Part Number is 73-102377-03 Part Revision is 07 Manufacture Date is Year 2022 Week 22 Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 49
Model number is NXA-PAC-2KW-PI H/W version is 0 Part Number is 341-1888-01 Part Revision is A0 Manufacture Date is Year 2021 Week 47 Serial number is POG2547JAH6 CLEI code is CMUPAFGCAA Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
You can display information about the environment, for the switch by using the show environment command. switch# show environment Fan: --------------------------------------------------------------------------- Model Direction Status --------------------------------------------------------------------------- Fan1(sys_fan1) N9K-C9400-FAN-PI front-to-back Fan2(sys_fan2) N9K-C9400-FAN-PI front-to-back Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
You can display information about the environment, for the switch by using the show environment temperature command. ASW4_QP_LEM# show environment temperature show environment temperature Temperature: -------------------------------------------------------------------- Module Sensor MajorThresh MinorThres CurTemp Status (Celsius) (Celsius) (Celsius) -------------------------------------------------------------------- Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 55
Managing the Switch Displaying Environment Temperature for the Switch FRONT BACK Quadpeaks ASW4_QP_LEM# Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
Page 56
Managing the Switch Displaying Environment Temperature for the Switch Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
See below. The cabinet or rack must also meet the following requirements: • The minimum vertical rack space per Cisco Nexus switch chassis must be one RU (rack units), equal to 1.75 inches (4.4 cm). • The width between the rack-mounting rails must be at least 17.75 inches (45.0 cm) if the rear of the device is not attached to the rack.
• The horizontal distance between the chassis and any adjacent chassis should be 6 inches (15.2 cm), and the distance between the chassis air vents and any walls should be 2.5 inches (6.4 cm). Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
LEM LEDs, on page 58 • Fan LEDs, on page 59 • Power Supply LEDs, on page 60 CPU Card LEDs This table provides information about CPU Card LEDs for Cisco Nexus 9400 Series switches. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
The MGMT port is transmitting or receiving The MGMT port is not transmitting or receiv LEM LEDs This table provides information about Line Expansion Module (LEM) LEDs for Cisco Nexus 9400 Series switches. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
The port is faulty and disabled. The port is not active or the link is not connected. Fan LEDs This table provides information about fan LEDs for Cisco Nexus 9400 Series switches. Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide...
(amber) to blink and the module does not come online. The module has a runtime failure and is brought offline. Power Supply LEDs This table provides information about power supply LEDs for Cisco Nexus 9400 Series switches. Component Status Description...