INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner
unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimaanlage das Installationshandbuch gründlich
durchlesen.
MANUEL D'INSTALLATION
Veuillez lire le manuel d'installation en entier avant d'installer ce climatiseur pour éviter tout accident et vous
assurer d'une utilisation correcte.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore
d'aria.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner
installeert.
INSTALLATIONSMANUAL
Läs denna installationsmanual noga för säkert och korrekt bruk innan luftkonditioneringen installeras.
INSTALLATIONSMANUAL
Læs venligst denne installationsmanual grundigt, før De installerer airconditionanlægget, af hensyn til sikker og
korrekt anvendelse.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade
de ar condicionado.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙÂ
ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным
руководством по установке до выполнения установки кондиционера.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu
elkitab›n› dikkatle okuyunuz.
FOR INSTALLER
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
VOOR DE INSTALLATEUR
FÖR INSTALLATÖREN
TIL INSTALLATØREN
PARA O INSTALADOR
°π∞ ∞À∆√¡ ¶√À ∫∞¡∂π ∆∏¡ ∂°∫∞∆∞™∆∞™∏
ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘
ДЛЯ УСТАНОВИТЕЛЯ
MONTÖR ‹Ç‹N
English
Deutsch
Français
Español
Italiano
Nederlands
Svenska
Dansk
Português
∂ÏÏËÓÈο
Русский
Türkçe

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric Mr.Slim PEAD-RP60JA

  • Page 1 Air-Conditioners PEAD-RP35,50,60,71,100,125,140JA PEAD-RP35,50,60,71,100,125,140JAL INSTALLATION MANUAL FOR INSTALLER FOR INSTALLER English For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Zum sicheren und ordnungsgemäßen Gebrauch der Klimaanlage das Installationshandbuch gründlich durchlesen.
  • Page 2 [Fig. 3-1] 50~150 A Access door 1 600 mm or more B Electrical parts box 2 100 mm or more C Air inlet 3 10 mm or more D Air outlet 4 300 mm or more E Ceiling surface F Service space (viewed from the side) G Service space (viewed from the direction of arrow) (mm) Model...
  • Page 3 [Fig. 6-1] øB øA Model PEAD-RP35, 50 ø12.7 ø6.35 PEAD-RP60, 71, 100, 125, 140 ø15.88 ø9.52 a Indoor unit b Outdoor unit [Fig. 6-3] [Fig. 6-4] [Fig. 6-5] 90° a Burr c Spare reamer a Copper tubes c No good e Uneven a Flare nut b Copper tube/pipe...
  • Page 4 [Fig. 6-10] Max. 20m 1.5-2m Max. 300mm Correct piping Wrong piping A Insulation (9 mm or more) B Downward slope (1/100 or more) C Support metal K Air bleeder L Raised M Odor trap Grouped piping D O. D. ø32 PVC TUBE E Make it as large as possible.
  • Page 5 [Fig. 7-1] [Fig. 7-2] <A> In case of rear inlet Duct Air inlet Access door Canvas duct Ceiling surface Air outlet Leave distance enough to pre- vent short cycle <B> In case of bottom inlet A Filter B Bottom plate [Fig.
  • Page 6 [Fig. 8-2-1] [Fig. 8-2-2] A Screw holding cover (1pc) C Terminal box B Cover D Knockout hole E Remove [Fig. 8-2-3] [Fig. 8-2-4] F Use PG bushing to keep the weight of the cable and external force from being applied to J Terminal block for power source and indoor transmission the power supply terminal connector.
  • Page 7 [Fig. 8-3] A Indoor terminal block A Indoor terminal block 4 Always install an earth wire (1-core 1.5 mm longer than other cables B Earth wire (green/yellow) B Earth wire (green/yellow) C Indoor/outdoor unit connecting wire 3- 5 Remote controller cable core 1.5 mm or more Wire No ¥...
  • Page 8 [Fig. 8-7] Standard 1:1 Indoor/outdoor wiring OC(00) Signal receiving unit wiring A Outdoor unit B Refrigerant address C Indoor unit CN90 D Signal receiving unit [Fig. 8-8] A Signal receiving unit external B Center of Switch box C Switch box D Installation pitch E 6.5 mm (1/4 inch) F 70 mm (2 - 3/4 inch)
  • Page 9 [Fig. 8-12] Insert the minus screwdriver toward the arrow pointed and wrench it to remove the cover. A flat screwdriver whose width of blade is between 4 and 7mm (5/32 - 9/32inch) must be used. [Fig. 8-13] A Thin-wall portion B Bottom case C Remote controller wire D Conducting wire...
  • Page 10 [Fig. 8-16] JP41 JP42 CN32 CN105 CN3C CN41 CN2A CN51 CN22 CN90 CNXB2 CN4F CNXA2 CN44 CN20 CN2L CNXC2 <Indoor controller board> [Fig. 8-17] [Fig. 8-18] CN90 CN90 CN90 CN90 CN90 CN90 CN90 CN90 Pair number: 0 Pair number: 1 Pair number: 2 Pair number: 3 Pair number: 0...
  • Page 11 ⁄ Mode number [Fig. 8-21] ⁄ Setting number ⁄ Refrigerant address ⁄ Unit number A Filter button (<Enter> button) B TEST button TEMP. ON/OFF C Set Time button MENU ON/OFF FILTER BACK MONITOR/SET CHECK TEST D Timer On/Off button (Set Day button) OPERATION PAR-21MAA CLOCK...
  • Page 12 10.1 [Fig. 10-1] H Refrigerant gas cylinder for R410A with A Indoor unit siphon B Union I Refrigerant (liquid) C Liquid pipe J Electronic scale for refrigerant charging D Gas pipe K Charge hose (for R410A) E Stop valve L Gauge manifold valve (for R410A) F Outdoor unit M Service port G Refrigerant gas cylinder operating valve...
  • Page 13: Table Of Contents

    Contents 1. Safety precautions ................. 13 9. Test run ....................22 2. Selecting the installation location ............13 10. Maintenance ..................24 3. Selecting an installation site & Accessories ........... 14 4. Fixing hanging bolts ................14 5. Installing the unit ..................14 This Installation Manual describes only for the indoor unit and the connected 6.
  • Page 14: Selecting An Installation Site & Accessories

    3. Selecting an installation site & Accessories Warning: • Select a site with sturdy fixed surface sufficiently durable against the weight of unit. The unit must be securely installed on a structure that can sustain its weight. If • Before installing unit, the routing to carry in unit to the installation site should be the unit is mounted on an unstable structure, it may fall down causing injuries.
  • Page 15: Refrigerant Piping Work

    6. Refrigerant piping work 6.1. Refrigerant pipe 6.2.3. Putting nut on [Fig. 6-5] (P.3) [Fig. 6-1] (P.3) a Flare nut a Indoor unit b Copper tube b Outdoor unit • Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube Refer to the Instruction Manual that came with the outdoor unit for the restrictions on having completed burr removal.
  • Page 16 6. Refrigerant piping work Refrigerant pipe insulation Tighten the cap to the service port to obtain the initial status. • After connecting refrigerant piping, insulate the joints (flared joints) with thermal insulation tubing as shown below. Retighten the cap [Fig. 6-9] (P.3) A Pipe cover (small) (accessory) Leak test B Caution:...
  • Page 17: Duct Work

    6. Refrigerant piping work 6.6. Confirming drain discharge 3.Perform the test run in cooling mode, or connect the connector to the ON side of SWE on the Indoor controller board. (The drain pump and the fan are forced to Make sure that the drain-up mechanism operates normally for discharge operate without any remote controller operation.) Make sure using a transparent and that there is no water leakage from the connections.
  • Page 18: Electrical Work

    8. Electrical work 8.1. Power supply 8.1.2. Separate indoor unit/outdoor unit power supplies (For PUHZ application only) 8.1.1. Indoor unit power supplied from outdoor unit The following connection patterns are available. The following connection patterns are available. The outdoor unit power supply patterns vary on models. The outdoor unit power supply patterns vary on models.
  • Page 19 8. Electrical work 8.2. Indoor wire connection [Fig. 8-5] (P.7) A For installation in the switch box: Work procedure B For direct installation on the wall select one of the following: 1.Remove 2 screws to detach the electric component cover. •...
  • Page 20 8. Electrical work 8.4.2. Signal Receiving Unit [Fig. 8-11] (P.8) 1) Sample system connection H Seal around here with putty [Fig. 8-7] (P.8) I Remote controller wire J Seal around here with putty Only the wiring from the signal receiving unit and between the remote controllers is shown in [Fig.
  • Page 21 8. Electrical work 2) For wireless remote controller [Fig. 8-22] (P.11) 8.5. Function settings (Function selection via the 1. Changing the external static pressure setting. remote controller) 8.5.1 Function setting on the unit (Selecting the unit functions) • Be sure to change the external static pressure setting depending on the duct and 1) For wired remote controller [Fig.
  • Page 22: Test Run

    9. Test run 9.1. Before test run 9.2. Test run 9.2.1. Using wired remote controller After completing installation and the wiring and piping of the indoor and outdoor units, check for refrigerant leakage, looseness in the power supply or control 1 Turn on the power at least 12 hours before the test run.
  • Page 23 9. Test run 9.3. Test run 4 Press the MODE button B to activate HEAT mode, then check whether warm air is blown out from the unit. 9.3.1. Using wireless remote controller (option) 5 Press the FAN button C and check whether fan speed changes. [Fig.
  • Page 24: Maintenance

    9. Test run On the wireless remote controller with conditions above, following phenomena takes place. • No signals from the remote controller are accepted. • OPE lamp is blinking. • The buzzer makes a short ping sound. Note: Operation is not possible for about 30 seconds after cancellation of function selection. (Correct operation) For description of each LED (LED1, 2, 3) provided on the indoor controller, refer to the following table.
  • Page 25 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. KB79M256H01...

Table of Contents