Page 1
INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE30955S LSE3094S LRE30855S LRE3091S LRE30755S LSE3092S LRE30451S LSES302ST LRE30757S LSRE307ST LRE30453S LSE3392S www.lg.com...
TABLE OF CONTENTS TABLE OF CONTENTS SAFETY 3 Before You Begin 3 Important Safety Instructions 5 Prepare to Install the Range PREPARE TO INSTALL RANGE 6 Installation Drawings (LRE/LSRE Series only) 7 Installation Drawings (LSE Series only) ELECTRICAL CONNECTIONS 8 Electrical Connection Requirements 8 Connect Range Cord 9 3-Wire Connection With a Power Supply Cord 10 4-Wire Connection With a Power Supply Cord...
Remove all tape and packing materials before using the range. Dispose of all plastic bags after unpacking the range. Never allow children to play with packing materials. You can download the installation and owner’s manual at: http://www.lg.com. IMPORTANT SAFETY INSTRUCTIONS Read and follow all instructions before using your oven to prevent the risk of fire, electric shock, personal injury, or damage when using the range.
Page 4
SAFETY WARNING • Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with ranges with closed-loop connectors or open-end spade lugs with upturned ends shall be used. The middle (neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of the main terminal block.
SAFETY PREPARE TO INSTALL THE RANGE WARNING • The information in this manual should be TOOLS NEEDED followed exactly. - A fire or electrical shock may result causing property damage, personal injury or death. Phillips Screwdriver Level WARNING Flat-blade Adjustable Wrench Tip - Over Hazard Screwdriver A child or adult can tip the range and be...
PREPARE TO INSTALL THE RANGE INSTALLATION DRAWINGS (LRE/LSRE Series only) NOTE SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR. CLEARANCES AND DIMENSIONS (Figure 1) To install range refer to the following Figure 1. For installation in CANADA, a Free-standing range is not to be installed closer than (12mm) from any adjacent surface.
PREPARE TO INSTALL THE RANGE INSTALLATION DRAWINGS (LSE Series only) NOTE SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR CLEARANCES AND DIMENSIONS (Figure 1) To install range refer to the following Figure 1. For installation in CANADA, a Free-standing range is not to be installed closer than (12mm) from any adjacent surface.
ELECTRICAL CONNECTIONS ELECTRICAL CONNECTION CONNECT RANGE CORD REQUIREMENTS The Rear Access cover must be removed. Loosen the three screws with a screwdriver. The terminal block will This appliance must be installed and grounded on a then be accessible. branch circuit by a qualified technician in accordance with the National Electrical code ANSI/NFPA NO.
ELECTRICAL CONNECTIONS 3-WIRE CONNECTION WITH A POWER SUPPLY CORD WARNING • The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main Cord strain relief terminal block.
Page 10
ELECTRICAL CONNECTIONS 4-WIRE CONNECTION WITH 3-WIRE CONNECTION: CONDUIT A POWER SUPPLY CORD Install the conduit as follows: WARNING Remove the Conduit connection plate from the rear of drawer body and rotate it as shown in Figure 5. The • Only a 4-conductor power-supply cord kit rated conduit hole (1 ”) must be used.
ELECTRICAL CONNECTIONS 4-WIRE CONNECTION: CONDUIT 1. Follow the instructions under “Install the conduit as 4-wire connection follows” on page 10 to correctly install the strain relief. Black White Red DO NOT install the conduit without a strain relief. Terminal 2. Loosen the 2 lower left and right screws from the block terminal block.
INSTALL THE RANGE Replace the access cover on the range back. To replace the wire cover, insert double projections in the pockets located below the opening and tighten the three screws. Lower range Access cover leveler Raise range Use a spirit level to check your adjustments. Place the level diagonally on the oven rack, and check each direction for level.