Summary of Contents for Fujitsu Airstage UTY-DTGYZ1
Page 1
REMOTE CONTROLLING MANUAL TOUCH PANEL CONTROLLER Keep this manual for future reference. 遥控的使用说明书 触摸屏控制器 使用产品前请仔细阅读本使用说明书 请保留本说明书以供今后参考 ANLEITUNG FÜR DIE FERNBEDIENUNG UTY-DTGYZ1 SENSORBILDSCHIRMSTEUERUNG UTY-DTGGZ1 MODE D’EMPLOI DE TÉLÉCOMMANDE CONTRÔLEUR DE PANNEAU À CONTACT MANUAL DEL CONTROL REMOTO CONTROLADOR DE PANEL DE CONTACTO MANUALE DEL TELECOMANDO DISPOSITIVO DI CONTROLLO DI PANNELLO A CONTATTO ΕΓΧΕΙΡΙΔΙΟ...
Page 3
2-1-11 Resetting “Filter Sign” ...................................21 2-1-12 Test operation ......................................21 2-1-13 Checking “Special State” of R.C.Groups / Groups ..........................22 2-1-14 Ending “Operation Setting” ...................................22 "The following pages are only for administrator and installer." Chapter 3 SYSTEM SETTING 3-1 Remote Connection Settin ...
INTRODUCTION Safety precautions • The "SAFETY PRECAUTIONS" indicated in the manual contain important information pertaining to your safety. Be sure to observe them. • For details of the operation methods, refer to this manual. • Request the user to keep the manual on hand for future use, such as for relocating or repairing the unit. This mark indicates procedures which, if im- This mark indicates procedures which, WARNING...
Overview This touch panel controller can remotely control indoor unit operation and status monitoring from PC Web browser connected by a LAN. These procedures for remotely controlling is described in this manual. Operation environment When indoor unit operation and status monitoring are performed by Web browser, the following personal computer environment is necessary.
Login (1) Start a browser and input the web page address in the address field. Web page address → http:// [Touch panel controller IP address] (2) When the "Enter" button is pressed, "Touch Panel Controller Login" screen opens. (3) Enter the user name and password. (For the initial value of user name and password, refer to the “Preparation”...
System outline Composition of basic screens The screens of touch panel controller consist of 3 functions; monitoring, control, and setting. MONITOR (Chapter 1) (Monitor mode) Icon List CONTROL (Chapter 2) (Operation Control) Operation Setting SETTING (for Administrator) (Operation Setting) SYSTEM SETTING (Chapter 3) HISTORY (Chapter 4) SYSTEM SETTING...
1-1-3 Changing group display hierarchy Use when changing the hierarchy of the group displayed on “Monitor Mode” screen. Monitor Mode (Icon) Notes The following 3 buttons move the group hierarchy screen. Moves to the hierarchy at the top of the screen Moves the screen to the next higher hierarchy Moves the screen to the next lower hierarchy 1-1-4...
Notes The following 6 buttons scroll the screen. Scrolls the screen up in page units. Scrolls the screen down in page units. Scrolls the screen up 1 line at a time. Scrolls the screen down 1 line at a time. Scrolls the screen to the left 1 column at a time.
1-1-7 Deselecting all R.C.Groups / Groups Deselect all the R.C.Groups / Groups on “Monitor Mode” screen. ● Click “Clear All” button. All the selected R.C.Groups / Groups become the deselected state. ¡ Monitor Mode (Icon) 1-1-8 Starting (On) operation of all R.C.Groups / Groups Click “Select All”...
1-1-10 Starting (On) operation of selected R.C.Groups / Groups Select the relevant R.C.Groups / Groups from R.C.Group / Group on “Monitor Mode” screen. ● The R.C.Groups / Groups become the selected state (blue). ¡ Click “On” button. The R.C.Groups / Groups start to operate under the preset conditions. ¡...
1-1-12 Setting the temperature ● Set the temperature on “Monitor Mode” screen. Select the relevant R.C.Groups / Groups from R.C.Group / Group on “Monitor Mode” screen. The R.C.Groups / Groups become the selected state (blue). ¡ Click “Set Temp.” button. Click the temperature you want to set.
When “Error List” button is clicked, “Error List” window is reopened. Monitor Mode (List) / Error List Note “Error List” button is displayed when “Error List” window was closed. ● “Error List” button is continuously displayed until the error is resolved. 1-1-14 Displaying the registered unit address (only for administrator) ●...
1-1-15 Selecting the R.C.Groups / Groups to be controlled ● Control the R.C.Groups / Groups on “Monitor Mode” screen. Select the relevant indoor units from R.C.Group / Group operating on “Monitor Mode” screen. The R.C.Groups / Groups become the selected state (blue). ¡...
Chapter 2 CONTROL Control 2-1-1 Main screens of Control Operation Setting Fan operation display Controlled group name display button R.C. Prohibition button Set Temp. display Up/Down Swing setting display Control objective display Up/Down Swing setting button Mode button “On/ Off” button “On/Off”...
2-1-3 Setting the operation mode Click the mode button to be selected. Operation Setting Notes • When the function does not exist at the objective unit, setting cannot be selected. Buttons with their operation prohibited cannot be clicked. • When “Operation Controlled” is displayed, there is no cooling and heating selection right. 2-1-4 Setting the temperature Select the set temperature using “”...
2-1-5 Setting the fan (air flow) Set the fan (airflow) by using the “” button, “” button, and "Auto" button. Operation Setting Note In "Fan" operation section, airflow switching steps are different depending on the indoor unit type to be operated. For details, refer to the indoor unit operating manual.
2-1-7 Setting “Air Flow Direction (up/down)” Set the up and down swing angle using “” button and “” button. 1 2 3 4 SWING Operation Setting Notes • When the function does not exist at the objective unit, setting cannot be selected. •...
2-1-9 Setting “Economy” operation Click “On” button or “Off” button. “Economy” operation set/reset is performed. Operation Setting Note When the function does not exist at the objective unit, setting cannot be selected. 2-1-10 Setting “Anti Freeze” operation Click “On” button or “Off” button. “Anti Freeze” operation set/reset is performed. Operation Setting Notes •...
2-1-11 Resetting “Filter Sign” Click “Reset” button Operation Setting Notes • When the function does not exist at the objective unit, setting cannot be selected. • ”Filter Sign” indicates the air clean filter cleaning interval set at the indoor unit. Reset the sign when the filter was cleaned.
2-1-13 Checking “Special State” of R.C.Groups / Groups The current special state of the system is displayed at “Special State” display section of “Optional Setting” screen. Operation Setting Notes The followings are displayed at “Special State” display section. “Special State” display items Contents Stand by (Defrost) Defrost operation...
Chapter 3 SYSTEM SETTING Remote Connection Setting 3-1-1 Main screens of remote connection setting "User Name" "Type" "Permissions" "R.C.Group" "Logout" button "Automatic Logout Time" "Delete" button "Edit" button "New" button "Back" button 3-1-2 Registering the new user of remote connection operation ●...
Page 26
When the new user or administrator is registered, click "New" button. “Remote User Setting" screen opens. ¡ When the registered item is edited, click "Edit" button. Hereafter, perform the same operation.) Remote Connection Setting Remote User Setting Input the user name using your PC keyboard. Input the password using your PC keyboard.
Page 27
● Set the "Permissions" (selection of available functions). Click "Edit" button. "Permissions" screen opens. ¡ Remote User Setting The functions the user is permit- Permissions ted to use are displayed in the "Permissions" field. The items displayed by black characters in the "Function List" are the functions the user is permitted to use.
Page 28
Set the "Unit Setting" (selection of available indoor units). ● Click "Edit" button. "Unit Setting" screen opens. ¡ Remote User Setting Set the R.C. Group that is available to the user or administrator by remote connection operation. ● To allow all the connected indoor units to be operated, click "Registration All" button. When setting individually the indoor units to be operated, click "Individual"...
Mail Setting ● When an error is generated at the touch panel controller or a registered outdoor unit or indoor unit, an E- mail can be sent to a pre-registered address. ● This unit does not have the server function. To use this function, SMTP server outside this unit or E-mail receiving terminal must be connected by network (LAN).
3-2-3 Setting the server information Mail Setting Input the server information. ● Click "Edit" button on the "Server Setting" field. "Server Setting" screen opens. ¡ Server Setting Set the server. Input "Sender E-mail Address", "Outgoing E-mail Server (SMTP)", "Port", "Authentication", "Incoming mail (POP3)", "Account Name", and "Password".
3-2-4 Setting the E-mail destination. Mail Setting Set the mail destination. ● Check the check box. Input the destination name in the "Name" field. Input the E-mail address of destination. When the "Transmission Test" button is clicked, test transmission of the set E-mail information is possible. When the setting is complete, click "OK"...
Chapter 4 HISTORY History Display 4-1-1 Main screens of history setting Error History Error History list screen Screen display scroll (up/down) button Screen display scroll (left/right) button “Export Data” button “Erase All” button “Back” button Status History Remote Controller Group screen scroll (up/ down) button History screen scroll (up/ down) button History display screen...
Operation History Operation History list screen Screen display scroll (up/down) button “Export Data” button “Erase All” button “Back” button Version Version screen “Back” button 4-1-2 Displaying error history ● From Monitor Mode screen to Error History screen Click “History” button. “History”...
Click “Error History” button. “Error History” screen opens. ¡ ● “Error History” of each indoor unit, outdoor unit, and touch panel controller is displayed. History Notes • There are 4 buttons on “History” screen: “Error History”, “Status History”, “Operation History”, and “Version”. •...
4-1-4 Deleting all error history data Click “Erase All” button. “Erase All” screen opens. ¡ Error History Click “OK” button. All saved error history is deleted. ¡ Erase All Click “Back” button. “History” screen opens. ¡ En-34...
4-1-5 Displaying status history Click “Status History” button. “Status History” screen opens. ¡ ● “Status History” of each indoor unit is displayed. History Click the R.C. Group name you want to confirm from the RC group list. Display of the selected name becomes blue. ¡...
Click "Back" button. “History” screen opens. ¡ 4-1-7 Deleting all status history data ● Delete “Status History” data. Click “Erase All” button. “Erase All” screen opens. ¡ Status History Click “OK” button. All saved status history is deleted. ¡ Erase All Click “Back”...
4-1-8 Displaying operation history Click “Operation History” button. “Operation History” screen opens. ¡ ● The contents of operation of other equipment from the touch panel controller and the contents of setting changes made by touch panel controller can be checked. History Note The date and time operation was performed, the units that performed a change and the contents of operation are displayed...
4-1-11 Displaying version information Click “Version” button. “Version” screen opens. ¡ ● Check the touch panel controller software version contents. History Note The touch panel controller software version information can be checked at “Version” screen. Confirmation ends. ¡ When confirmation is complete, click “Back” button. “History”...
Chapter 5 OTHERS Error code •For the details or the indoor unit or outdoor unit error when checking the error contents, refer to the error codes in each installa- tion manual. Error code Contents 16.1 Transmission PCB connection error 16.3 LAN communication error 16.4 Peripheral device network communication error...