Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation
Guide
First Published: 2021-10-18
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Nexus 9332D-GX2B

  • Page 1 Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide First Published: 2021-10-18 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 Any products and features described herein as in development or available at a future date remain in varying stages of development and will be offered on a when-and if-available basis. Any such product or feature roadmaps are subject to change at the sole discretion of Cisco and Cisco will have no liability for delay in the delivery or failure to deliver any products or feature roadmap items that may be set forth in this document.
  • Page 3: Table Of Contents

    Installation Options with Rack-Mount Kits Airflow Considerations Installation Guidelines Unpacking and Inspecting the Switch Installing the Switch Using the NXK-ACC-KIT-1RU Rack-Mount Kit Installing the Airflow Sleeve (N9K-AIRFLOW-SLV) Grounding the Chassis Starting the Switch Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 4 Cable Management Guidelines A P P E N D I X B System Specifications Environmental Specifications Switch Dimensions Switch and Module Weights and Quantities Transceiver and Cable Specifications Switch Power Input Requirements Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 5 A P P E N D I X C LEDs Switch Chassis LEDs Fan Module LEDs Power Supply LEDs A P P E N D I X D Additional Kits Rack Mount Kit NXK-ACC-KIT-1RU Airflow Sleeve Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 6 Contents Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 7: Overview

    Overview • Overview, on page 1 Overview The Cisco Nexus 9332D-GX2B switch (N9K-C9332D-GX2B) is a 1-rack unit (RU), fixed-port switch designed for spine-leaf-APIC deployment in data centers. This switch includes the following ports: • 400-Gigabit QSFP-DD ports (32) • 10-Gigabit SFP+ ports (2) •...
  • Page 8 The following figure shows the switch features on the port side of the chassis. LEDs 400-Gigabit QSFP-DD ports (32) 10-Gigabit SFP+ ports (2) To determine which transceivers, adapters, and cables are support this switch, see the Cisco Transceiver Modules Compatibility Information document. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 9 If the switch has port-side exhaust airflow (blue coloring for fan modules), you must locate the ports in the hot aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 10 Overview Overview Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 11: Preparing The Site

    Altitude Requirements Altitude rating is 10,000 ft (3048 m). For China, it is 6,562 ft (2000 m). Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 12: Dust And Particulate Requirements

    The wiring is unlikely to emit radio interference if you use a twisted-pair cable with a good distribution of grounding conductors. If you exceed the recommended distances, use a high-quality twisted-pair cable with one ground conductor for each data signal when applicable. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 13: Shock And Vibration Requirements

    Planning for Power Requirements The switch includes two power supplies (1-to-1 redundancy with current sharing) in one of the following combinations: • Two 1500-W AC power supplies • Two 1100-W DC power supplies Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 14: Airflow Requirements

    You can identify the airflow direction of each fan and power supply module by its coloring as follows: • Blue coloring indicates port-side exhaust airflow. • Burgundy coloring indicates port-side intake airflow. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 15: Rack And Cabinet Requirements

    Provide the chassis with adequate clearance to route cables, provide airflow, and maintain the switch. For the clearances required for an installation of this chassis in a four-post rack, see the following figure. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 16 19.0 in (43.3 cm) Note Both the front and rear of the chassis must be open to both aisles for airflow. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 17: Installing The Chassis

    Starting the Switch, on page 22 Safety Before you install, operate, or service the switch, see the Regulatory, Compliance, and Safety Information for the Cisco Nexus 3000 and 9000 Series for important Safety Information. Warning Statement 1071 Warning Definition IMPORTANT SAFETY INSTRUCTIONS Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
  • Page 18 Only an instructed person or skilled person should be allowed to install, replace, or service this equipment. See statement 1089 for the definition of an instructed or skilled person. There are no serviceable parts inside. To avoid risk of electric shock, do not open. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 19 This equipment must be grounded. To reduce the risk of electric shock, never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 20: Installation Options With Rack-Mount Kits

    You can install the switch using the following rack-mount options: • Rack-mount kit (NXK-ACC-KIT-1RU) which you can order from Cisco. This option offers you easy installation, greater stability, increased weight capacity, added accessibility, and improved removability with front and rear removal.
  • Page 21: Airflow Considerations

    50 to 60 Hz. Caution To prevent loss of input power, ensure the total maximum loads on the circuits supplying power to the switch are within the current ratings for the wiring and breakers. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 22: Unpacking And Inspecting The Switch

    You must supply the eight 10-32 or 12-24 screws required to mount the slider rails and switch to the rack. Before you begin • You have inspected the switch shipment to ensure that you have everything ordered. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 23 The holes that you use depend on the requirements of your rack and the amount of clearance required for interface cables (3 inches [7.6 mm] minimum) and module handles (1 inch [2.5 mm] minimum). Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 24 Holding the switch with both hands, position the two rear rack-mount brackets on the switch between the rack or cabinet posts that do not have slider rails attached to them (see the following figure). Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 25 Tighten the 10-32 screws to 20 in-lb (2.26 N·m) or tighten the 12-24 screws to 30 in-lb (3.39 N·m). Step 5 If you attached a grounding wire to the chassis grounding pad, connect the other end of the wire to the facility ground. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 26: Installing The Airflow Sleeve (N9K-Airflow-Slv)

    Holding the airflow sleeve level, insert screws (12-24 or 10-32, depending on the rack type) in each of the two front rack-mount flanges (using a total of two screws) and into the cage nuts or threaded holes in the vertical rack-mounting rails (see the following figure). Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 27: Grounding The Chassis

    Warning Statement 1046 Installing or Replacing the Unit To reduce risk of electric shock, when installing or replacing the unit, the ground connection must always be made first and disconnected last. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 28: Starting The Switch

    This equipment is designed to boot up in less than 30 minutes, dependent on its neighboring devices being fully up and running. Before you begin • The switch must be installed and secured to a rack or cabinet. • The switch must be adequately grounded. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 29 Turn off the circuit breaker for the power source to avoid an electrical shock hazard. b) Verify that the power cable wires from the power source are connected to a connector block. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 30 A setup utility automatically launches the first time that you access the switch and guides you through the basic configuration. For instructions on how to configure the switch and check module connectivity, see the appropriate Cisco Nexus 9000 Series configuration guide.
  • Page 31: Connecting The Switch To The Aci Fabric

    As shown in the following figure, each APIC is connected to one or two leaf switches and each leaf switch should be connected to every spine switch in the same fabric. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 32: Preparing To Connect To Other Devices

    Cisco equipment. In situations where long parallel cable runs cannot be separated by at least 3.3 feet (1 meter), we recommend that you shield any potential noise sources by housing them in a grounded metallic conduit.
  • Page 33: Connecting Leaf Switches To Apics

    Connecting Leaf Switches to APICs You must downlink one or two (recommended for redundancy) Cisco Nexus 9300 platform ACI-mode leaf switches to each Application Policy Infrastructure Controller (APIC) in your ACI fabric. The type of virtual interface card (VIC) installed on the APIC determines the types of interface cables that you can use to connect the leaf switches to the APICs.
  • Page 34 Connect the other end of the interface cable to a downlink port on a leaf switch. • For a Cisco 10GBASE-LR or -SR transceiver and cable, insert the transceiver into a downlink optical port on a leaf switch before connecting the cable to the transceiver.
  • Page 35: Connecting Leaf Switches To Spine Switches

    You cannot include NX-OS line cards in the same chassis when running in ACI mode. Note Multiple uplinks from a leaf switch to a spine switch is supported. A symmetrical topology is recommended so that all devices have equal access to resources. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 36: Migration Of Nodes From A First Generation Switch To A Second Generation Switch

    Migration of Nodes From a First Generation Switch to a Second Generation Switch You have first generation Cisco Nexus 9000 series switches that may or may not be comprising a virtual port channel (vPC). You are migrating to second generation Cisco Nexus 9000 series switches using the same cables.
  • Page 37 From the Cisco APIC GUI, perform the Remove From Controller operation for the operational secondary vPC switch node. The Cisco APIC clean reboots the switch. Wait for about 10 minutes for this operation to finish. This action prompts all traffic to use the other first generation switch for data traffic.
  • Page 38: Setting Up An Optional Console Interface

    Register the new second generation switch with the Cisco APIC. Register the new node with the same node name and node ID. This switch becomes part of the fabric. The Cisco APIC pushes the policies to the new switch and keeps down the vPC legs because there is a mismatch of the generation of switches.
  • Page 39: Setting Up An Optional Management Connection

    DB-9 connector on the other end of the cable to the serial port on the console device. What to do next You can now perform the initial configuration for the switch (see the Cisco ACI Getting Started Guide). Setting Up an Optional Management Connection You can optionally set up an out-of-band management connection for monitoring and troubleshooting purposes.
  • Page 40 Connecting the Switch to the ACI Fabric Maintaining Transceivers and Optical Cables Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 41: Replacing Components

    On the fan module that you are removing, press the two sides of the fan module handle together, and pull on the handles enough to unseat it from its connectors. Step 2 Holding the handle, pull the module out of the chassis. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 42: Installing A Fan Module

    • Ensure that the chassis is grounded. For grounding instructions, see Grounding the Chassis, on page Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 43: Removing A Dc Power Supply

    (do not mix AC and DC power supplies in the same switch). Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 44: Installing A Dc Power Supply

    If you are using n+n power redundancy, there must be a separate power source for each power supply installed in the chassis (do not mix AC and DC power sources for the same switch). Otherwise, only one power source is required. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 45 Turn on the circuit breaker for the DC power source connected to the power supply. Step 4 Verify that the power supply is operational by making sure that the power supply LED is green. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 46 Replacing Components Installing a DC Power Supply Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 47: Rack Specifications

    • Standard 19-inch (48.3 cm) (two- or four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992). For more information, see Requirements Specific to Perforated Cabinets, on page Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 48: Requirements Specific To Standard Open Racks

    • The roof should be perforated with at least a 20 percent open area. • The cabinet floor should be open or perforated to enhance cooling. The Cisco R Series rack conforms to these requirements. Cable Management Guidelines To help with cable management, you might want to allow additional space in the rack above and below the chassis to make it easier to route all of the fiber optic or copper cables through the rack.
  • Page 49: System Specifications

    Altitude rating is based on power supply installed; see critical components list in the system CB report for altitude rating. Switch Dimensions Switch Width Depth Height Cisco Nexus 9332D-GX2B 17.3 inches (43.9 cm) 23.9 in (60.8 cm) 1.72 inches (4.4 cm) (1 RU) Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 50: Switch And Module Weights And Quantities

    1442 W 4,920.308 BTUs per hour Power Specifications Power specifications include the specifications for each type of power supply module. 1100-W DC Power Supply Specifications These specifications apply to the following power supplies: Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 51: 1500-W Ac Power Supply Specifications

    3.3 V Efficiency rating Climate Savers Platinum Efficiency (80Plus Platinum certified) Form factor 1.75x2.15x13.13 Power Cable Specifications The following sections specify the power cables that you can order and use with this switch. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 52: Power Cables For Nxa-Pac-1500W Power Supplies

    Power Cord, 250VAC 13A, EU 9.84 feet (3 m) 0.26 kg CAB-C15-CBN-CK Power Cord, 250VAC 13A, China 9.84 feet (3 m) 0.32 kg CAB-PWR-C15-CHN-A Power Cord, 250VAC 10A, China 8.2 feet (2.5 m) 0.32 kg Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 53: Dc Power Cable Specifications

    Safety • CAN/CSA-C22.2 No. 60950-1 Second Edition • CAN/CSA-C22.2 No. 62368-1-19 Third Edition • NRTL 60950-1 Second Edition • IEC 62368-1 • EN 62368-1 • AS/NZS 62368-1 • GB4943 • UL 62368-1 Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 54 • CNS13438 Class A EMC: Immunity • EN55024 • CISPR24 • EN300386 • KN 61000-4 series RoHS The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 55: Appendix Cleds

    Amber Port admin state is 'Disabled, or the SFP is absent, or both. Port admin state is 'Enabled' and SFP is present, but interface is not connected. Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 56: Fan Module Leds

    • Power supply is installed in the chassis but was disconnected from the power source. Flashing amber Power supply is installed without a connection to a power source. (10 seconds) then amber Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 57 LEDs LEDs OK LED FAIL or FAIL/ID Status Amber Power supply failure—possibly one of the following conditions: • Over voltage • Over current • Over temperature • Power supply fan failure Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 58 LEDs LEDs Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 59: Additional Kits

    Not applicable Hazardous substances list for customers in China The following table lists and illustrates the console cable (CAB-CONSOLE-RJ45) that can be ordered. Illustration Description Quantity Console cable with DB-9F and RJ-45F connectors Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...
  • Page 60: Airflow Sleeve

    Additional Kits Airflow Sleeve Airflow Sleeve The following table lists and illustrates the airflow sleeve (N9K-AIRFLOW-SLV). Illustration Description Quantity Airflow sleeve Cisco Nexus 9332D-GX2B ACI-Mode Switch Hardware Installation Guide...