The safety precautions and warnings are to ensure your safety and protect you from harm or damage to the product. The information contained in this manual was accurate at the time of production, however Genpower Ltd & JCB may make modifications to the product without notification. JCB-SH70D...
This WILL cause server burns and injury. Diesel Fuelling Warning: ONLY fill this machines with diesel or suitable fuel. When fueling ensure the machine is OFF, away from an open flame or ignition source. JCB-SH70D Instruction & User Manual...
> Do not overreach. Keep proper footing and balance at all times. This enables better control of the machine in unexpected situations. Extending your body too far can result in a loss of balance and you may fall which will result in injury. JCB-SH70D Instruction & User Manual...
> Keep the machine in good operating condition. Operating the machine in poor or questionable condition could result in serious injury. > Be sure all safety devices are in working order and warning labels are in place. These items are installed for your safety. JCB-SH70D Instruction & User Manual...
> Do not carry passengers. > Always turn off the machine and ensure that all moving parts have come to a complete stop before making any repairs, adjustments, or inspections. JCB-SH70D Instruction & User Manual...
All fuel storage should be in accordance with federal, state, or local authorities have jurisdiction. > NEVER use this heater in living or sleeping areas. > NEVER use this heater where flammable vapours may be present. JCB-SH70D Instruction & User Manual...
> All trailing cables should be routed so as not to cause any kind of trip hazard. > NEVER work on or near electricity with wet hands, wet clothing and wet gloves. JCB-SH70D Instruction & User Manual...
DO NOT enter a room you suspect of having carbon monoxide present – instead call the emergency services. Contact a Doctor immediately or go to Hospital – let them know that you suspect carbon monoxide poisoning. JCB-SH70D Instruction & User Manual...
> When fuel is spilled on yourself or your clothes, wash your skin and change clothes immediately. > ALWAYS clean up spills promptly using absorbent granules and a lidded bin. JCB-SH70D Instruction & User Manual...
(such as a water heater, furnace, or clothes dryer). Allow the engine to cool before storing in any enclosure. > Replace all fuel tank and container caps securely and wipe up spilled fuel. Never operate the unit without the fuel cap securely in place. JCB-SH70D Instruction & User Manual...
Gasses from charging batteries are highly flammable and great care should be taken to charge in well ventilated areas. There is an explosion risk if the battery terminals are short circuited, when connecting/disconnecting ALWAYS exercise great care so that the terminals or battery JCB-SH70D Instruction & User Manual...
Limit the working time to a minimum. For your personal protection and protection of people working nearby it is also advisable for them to wear hearing protection. > See Certificate of Conformity section for Outdoor Noise declaration of conformity. JCB-SH70D Instruction & User Manual...
1-K Kerosene, and care should be taken to provide more fresh air ventilation to accommodate any added contaminants that may be added to the heated space. Use of #1 or #2 fuel oil may result in more periodic maintenance. JCB-SH70D Instruction & User Manual...
Gauge showing the current Fuel Pressure 10. Flame Cone - An element that helps to disperse the outlet heat Dimensions A. 738mm F. 619mm B. 506mm G 895mm C. 776mm H. 406mm D. 763mm I. 245mm E. 200mm JCB-SH70D Instruction & User Manual...
6. Place a wheel, followed by a washer. Secure this into place using the Cotter Pins. Simply insert the cotter pin through the hole in the axle, until holds into place. 7. Repeat on both sides and secure the Wheel Covers JCB-SH70D Instruction & User Manual...
>NEVER use Diesel (1-K kerosene) that has been stored from one season to the next. It deteriorates over time. OLD DIESEL (1-K kerosene) WILL NOT BURN PROPERLY IN THIS HEATER. >Use diesel in the heater/ 1-K kerosene is a suitable substitute. JCB-SH70D Instruction & User Manual...
Always provide a fresh air opening in the heated space of at least three square feet (2800sq.cm) for each 29kW/hr of heater output. The following are some examples.. -A two-car garage door raised 15.24cm (6 inches) -A single-car garage door raised 15.24cm (9 inches) JCB-SH70D Instruction & User Manual...
Simply turn the power switch to “OFF” position and unplug the power cord. Operation- Restarting Wait ten seconds after shutting off the heater. Turn the power switch to “ON” position. Be sure to follow all starting procedure precautions. JCB-SH70D Instruction & User Manual...
>To drain the fuel tank, simply remove the Drain Plug bolt and washer >Allow the fuel to flow out. >Once all the fuel has been removed, Re- >install the Washer and Drain Plug. Drain Hole Washer Drain Plug JCB-SH70D Instruction & User Manual...
>The photocell should be cleaned at least once per heating season or more depending on condition. >Use a cotton swab dipped in water or alcohol to clean the lens of the photocell. *NOTE: the proper photocell position as noted in the diagrams. Photo Lens Incorrect Position Circuit Board Correct Position JCB-SH70D Instruction & User Manual...
>Remove the screw that secures the Ignition Electrode. Now Remove the Ignition Electrode >After removing the electrode, clean the terminals with a wire brush. >Re-gap the terminals to 0.14’’(3.5mm) if required. Screw Ignition Electrode Ignition Wires Spark Gap Burner Head JCB-SH70D Instruction & User Manual...
Remove all accumulated dust and dirt with a damp cloth, taking care not to bend any of the fan blades. Be sure fan blades are dry before re-starting the heater. For fan removal, see below. Set Screw Motor Shaft Fan Blade JCB-SH70D Instruction & User Manual...
NOTE: Use of diesel (1-K kerosene) may require additional maintenance. Using this heater without proper maintenance or with contaminated or old fuel may lead to improper combustion and possible soot production. SUITABLE FUELS ARE ESSENTIAL. JCB-SH70D Instruction & User Manual...
>Replace/Clean Fuel Filter, then reattach the bottom Fuel Line first. Return back into it's position. >Reattach the top Fuel Line and replace Control Panel Cover Photocell Wire Circuit Board Fuel Filter Screw Fuel Line Circuit Panel Cover Power Switch Power Switch JCB-SH70D Instruction & User Manual...
Correct pump pressure is 31Kpa / 4.5Psi For best measurement of pressure, test with full tank of fuel. Optimum pressure occurs when the nose cone is cherry red and there are no extending flames from the heater. Adjustment Screw Wiring Diagram JCB-SH70D Instruction & User Manual...
2. Check power cord and extension cord 4. Improper electrical connection between to insure of proper connection, test power temperature limit sensor and circuit board. supply. 3. Check/replace fuse. 4. Inspect all electrical connection (see wiring diagram). JCB-SH70D Instruction & User Manual...
Specifications Model JCB-SH70D Heat Output (kW) Heat Output (BTU) 68.243 Fuel Consumption (L/hr) Fuel Tank Capacity (L) Kerosene/Diesel Fuel Type Heating Area (m Pump Pressure (Kpa) Power Supply 230V 50Hz 5A Phase Type Single 16.5 Net Weight (kg) JCB-SH70D Instruction & User Manual...
We would be delighted if you left us positive feedback! To leave a review, please go to: uk.trustpilot.com Ordering Spare Parts You can find the spare part you are looking for at power-spares.co.uk JCB-SH70D Instruction & User Manual...
Our friendly aftersales team will be more than happy to help you. Phone Call our team on 01646 687 880 Email aftersales@genpower.co.uk Post Genpower Ltd, Isaac Way, Pembroke Dock, Pembrokeshire, SA72 4RW. Support Website Go to jcb-tools.co.uk JCB-SH70D Instruction & User Manual...
> You must comply with local regulations for the disposal of waste materials after mowing. > When disposing, do not pollute the environment with the machine, but hand it over to a disposal centre, in accordance with the local laws in force. JCB-SH70D Instruction & User Manual...
The person authorized to compile this technical file: Date: 01/12/2022 Signature Name/ title: Roland.J.Llewelin / Managing Director JCB Tools are a Licensee of J.C.Bamford Excavators ltd, operated via Genpower ltd. Address: JCB Tools ,Isaac Way, Prembroke Dock, SA72 4RW JCB-SH70D Instruction & User Manual...