Summary of Contents for United Appliances UAWH09-AD3D1
Page 1
Owner's Manual Original Instructions Split Air Conditioner Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local agent or visit www.unitedappliances.com for the electronic version. NOTE:Actual product may be different from graphics, please refer to actual products.
CONTENTS Safety precautions Parts name Installation notice Installation of outdoor unit Test and operation Configuration of connection pipe Manufacturer’s Limited Warranty...
Page 3
THIS MANUAL IS INTENDED FOR THE FOLLOWING MODELS: UAWH09-AD3D1 | UAWH09-DD3D1 UAWH12-AD3D1 | UAWH12-DD3D1 UAWH18-DD3D1 | UAWH24-DD3D1 UAWH30-DD3D1 | UAWH36-DD3D1...
Page 4
Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
Page 5
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 6
This equipment complies with FCC’s and IC’s RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
Safety precautions WARNING Installation Installation or maintenance should comply with nation- al electric safety regula- must be performed by qua - tions. ified professionals. Air Conditioner should be The appliance shall be in- properly grounded. Inco - stalled in accordance with rect grounding may cause national wiring regulations.
Page 8
Safety precautions CAUTION Installation Instructions for installation line. and use of this product are The yellow-green wire in provided by the manufac- air conditioner is ground- ing wire, which can't be turer. used for other purposes. Select a location which is The air conditioner is the out of reach for children first class electric appli...
Page 9
Safety precautions WARNING Operation and Maintenance ket. Otherwise, it may cause fire hazard. This appliance can be used Do disconnect power sup- by children aged from 8 ly when cleaning air years and above and per- sons with reduced physi- condit ioner.
Page 10
Safety precautions CAUTION Operation and Maintenance Air conditioner gives off Do not spill water on the re- burning smell. mote controller, otherwise Indoor unit is leaking. the remote controller may be broken. Do not use fire or hair dry- er to dry the filter to avoid deformation or fire hazard.
Installation notice WARNING sure that the unit is running in cooling mode. Then, fully close the valve at high pressure side (liquid valve). About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power.
Page 13
Selection of installation location Requirements for electric connection Basic requirement 8.The temperature of refrigerant circuit will be hi- Installing the unit in the following places may cau- gh, please keep the interconnection cable away se malfunction. If it is unavoidable, please from the copper tube.
Installation of outdoor unit Step 1: Fix the support of outdoor unit (select it according to the actual inst allation situation) drain vent chassis Select installation location according to outdoor drain joint Drain hose the house structure. Fix the support of outdoor unit on the cted location with expansion screws.
Page 15
Step 6: Tighten the union nu t with torque wrench Neaten the pipes by referring to the sheet below. The pipes should be placed along the wall, Tightening torque(N m) Hex nut diameter bent reasonably and hidden possibly. 1/4'' 15~20 eter of bending the pipe is 10cm.
Test and operation Check after installation ● Check according to the following requirement Use vacuum pump after finishing installation. Remove the valve caps on the liquid valve and Items to be checked Possible malfunction gas valve and the nut of refrigerant charging vent. 2.
Configuration of connection pipe Additional refrigerant charging amount for R22, R407C, R410A and R134a Standard length of connection pipe: 5m, 7.5m, Min. length of connection pipe is 3m. Max. length of connection pipe is shown as below. Max. length of connection pipe Max.
Page 18
Working temperature range C: Put on suitable insulating pipe UAWH09-AD3D1 UAWH09-DD3D1 D: Put on the union nut UAWH12-AD3D1 ● Remove the union nut on the indoor connection pipe and outdoor valve; UAWH12-DD3D1...
Page 19
UAWH09-AD3D1 UAWH09-DD3D1 UAWH12-AD3D1 UAWH12-DD3D1 UAWH18-DD3D1 UAWH24-DD3D1 UAWH30-DD3D1 UAWH36-DD3D1 Indoor side Outdoor side DB/WB(°C /°F) DB/WB(°C /°F) 26.7/19.4 50/24 Maximum cooling (80/67) (122/75) 26.7/- 24/18 Maximum heating (80/-) (75/65) NOTE ● The operating temperature range (outdoor tempera- ture) for cooling is -20 °C (-4°F) ~ 50°C (122°F); for...
MANUFACTURER’S LIMITED WARRANTY WARRANTOR. This Limited Warranty is offered by Dragon Trade International Corp , 1205 Highland Avenue, National City, California 91950, (“Manufacturer”) on the Products described below. PRODUCT. This Limited Warranty applies to the following products, residential and commercial air conditioner units manufactured by Manufacturer, collectively (“Product”). WHO MAY USE THIS WARRANTY .
Page 21
AUTHORIZED TO CHANGE THIS LIMITED WARRANTY IN ANY RESPECT OR CREATE ANY OTHER OBLIGATION OR LIABILITY FOR MANUFACTURER IN CONNECTION WITH THE PRODUCT OR ANY UNITED APPLIANCES EQUIPMENT. 5.07 UNDER NO CIRCUMSTANCES SHALL MANUFACTURER BE LIABLE FOR ANY INDIRECT, INCIDENTAL, SPECIAL, PUNITIVE OR CONSEQUENTIAL DAMAGES, INCLUDING,...
Page 22
5.10 In the event of a Product failure, the Product should be de-energized, but otherwise should remain as-is, where-is until inspected by an authorized technician, unless there is a life/safety threat or the likelihood of resultant physical damage to other property, in which case all appropriate safety precautions should be taken by qualified persons.
Page 23
COMPETENT JURISDICTION CONSUMER AND MANUFACTURER AGREE THAT ANY DISPUTE, CLAIM OR CONTROVERSY ARISING OUT OF THIS AGREEMENT OR THE USE OF THE PRODUCT, INCLUDING ISSUES OF ARBITRABILITY, SHALL, ("DISPUTE"), AT THE OPTION OF EITHER PARTY, BE RESOLVED BY BINDING ARBITRATION BEFORE A SINGLE NEUTRAL ARBITRATOR ADMINISTERED BY JUDICIAL ARBITRATION AND MEDIATION SERVICES ("JAMS") UNDER ITS APPLICABLE ARBITRATION RULES IN EFFECT AT THE TIME THE DISPUTE ARISES.
Page 24
8.03 Commencing the Arbitration. All claims in arbitration are subject to the same statues of limitations that would apply in court under applicable law. The Party bringing the claim must demand arbitration in writing and deliver the written demand by hand or first-class mail to the other party within the applicable statute of limitations period.
Page 25
RETURN AND EXCHANGE If you have any issues with your product or not entirely satisfied, please visit https://unitedappliances.com/us/returns-exchange/ or scan the QR code for all the steps.
Page 26
Imported by Dragon Trade International Corp. 614 5th Ave. Ste D, San Diego CA 92101-6964 Customer service: (800) 691-2050 unitedappliances.com...