hit counter script

Timer Operations; On Timer Or Off Timer; Program Timer; Sleep Timer - Fujitsu KM Series Operation Manual

Wall-mounted type
Table of Contents

Advertisement

■ Airfl ow direction range
Up/down airfl ow direction
Change by
Cooling, Dry
Heating, Fan
1
Swing operation by
2
Cooling, Dry
3
4
Heating
5
6
Fan *
* The Swing operation range depends on the airfl ow direction set before
the Swing operation.
NOTES:
• Do not adjust the airfl ow direction louvers by hand.
• In the Auto or Heating mode, the airfl ow direction stays position 1
for a while from the start of the operation.
• In the Cooling or Dry mode, the downward airfl ow can change to
the upper as follows. This feature is to prevent condensation from
dripping and damaging your property.
Condition:
Position 4-6 keeps for 30 minutes
Airfl ow adjusted to:
Position 3
• When using the mobile app, the up/down airfl ow can be selected
from 4 positions.

6. TIMER OPERATIONS

NOTE:
When [
] indicator on the indoor unit blinks, set the clock
and timer again. This blinking shows that the internal clock
goes wrong due to an interruption of the power supply.
6.1. On timer or Off timer
The On timer starts the operation at your desired time.
The Off timer stops the operation at your desired time.
1.
When you use the On timer, press
When you use the Off timer, press
2. Press
to set on time or off time.
(
)
Pressing the button: The time will change by +5/-5 minutes.
Pressing and holding the button: The time will change by +10/-10
minutes.
• To deactivate the On/Off timer, press
on the remote controller display.
The indicator will disappear.
NOTE:
If you set the Sleep timer after setting the On timer or Off
timer, the On timer or Off timer is canceled.

6.2. Program timer

The Program timer operates as a combination of the On timer and Off
timer.
1. Set On timer and Off timer. (Refer to "6.1. On timer or Off
timer").
The timer setting changes to the Program timer
automatically.
The timer whose setting time is closer to the current time works fi rst.
The order of the timer operation is displayed as follows:
Timer
Indicator on the remote controller display
On→Off timer
Off →On timer
NOTES:
● You can set the Program timer only within a span of 24 hours.
● If you set the Sleep timer after setting the Program timer, the
Program timer is canceled.
1 ⇄ 2 ⇄ 3 ( ⇄ 4 ⇄ 5 ⇄ 6)
1 ⇄ 2 ⇄ 3 ⇄ 4 ⇄ 5 ⇄ 6
1
4
3
6
1
4 or 3
6
.
.
while
is shown

6.3. Sleep timer

The Sleep timer supports your comfortable sleep by moderating the air
conditioner operation gradually.
1. Press
.
2. Press
to set the time until the operation
(
)
stops.
Each time you press the button, the time changes as follows:
0H
1H
2H
30M
00M
00M
(H: h, M: min)
NOTE: If you do not press any buttons for 5 seconds, the remote
controller display returns to the standby screen.
• The setting time is kept even if the Sleep timer fi nishes. To repeat
the Sleep timer, press
remote controller display.
• To deactivate the Sleep timer, press
on the remote controller display.
The indicator will disappear.
During the Sleep timer operation, the setting temperature changes as
the following fi gure.
In Heating mode
1 °C 2 °C 3 °C 4 °C
30 min
1 h
1.5 h
Set time
After the set time has elapsed, the air conditioner operation turns off .
NOTE:
If you set the On timer or Off timer after setting the Sleep
timer, the Sleep timer is canceled.

7. ENERGY SAVING OPERATION

7.1. Economy operation

It saves more electricity than other operation modes by changing the set
temperature to a moderate setting.
Press
to activate/deactivate the Economy
operation.
[
] indicator on the indoor unit will turn on.
Operation
mode
Cooling/Dry
Few degrees higher than the set temperature
Heating
Few degrees lower than the set temperature
NOTES:
• In the Cooling, Heating, or Dry mode, the maximum output of this
operation is approximately 70% of the usual operation.
• This operation cannot be performed during the temperature
monitoring by the Auto mode.
3H
5H
7H
9H
00M
00M
00M
00M
while
is not shown on the
while
is shown
In Cooling or Dry mode
Set time
Set
temperature
1 h
1 °C
2 °C
Room temperature
En-6

Advertisement

Table of Contents
loading